Direct measurement of cochlear parameters for automatic calculation of the cochlear duct length

被引:27
|
作者
Khurayzi, Tawfiq [1 ]
Almuhawas, Fida [1 ]
Sanosi, Abdulrahman [1 ]
机构
[1] King Saud Univ KSU, Coll Med, King Abdullah Ear Specialist Ctr KAESC, Dept Otolaryngol, Riyadh 11451, Saudi Arabia
关键词
DEEP ELECTRODE INSERTION; MORPHOLOGY; CORTI; ORGAN; RECONSTRUCTION; VARIABILITY; SIZE;
D O I
10.5144/0256-4947.2020.218
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BACKGROUND: Cochlear morphology and cochlear duct length (CDL) play important roles in the selection of appropriate electrodes. Cochlear parameters such as diameter (A value) and width (B value) are used as inputs for calculating the CDL. Current measurements of these parameters are inefficient and time consuming. Recently developed otological planning software (OTOPLAN) allows surgeons to directly measure these parameters and then automatically calculate the CDL. OBJECTIVES: The primary objective was to validate this new software for measuring the cochlear parameters and CDL. The secondary aim was to investigate the correlation between each cochlear parameter with the calculated CDL. DESIGN: Retrospective. SETTINGS: Ear specialist hospital. PATIENTS AND METHODS: The measurement of cochlear diameter (A value) was chosen as the validation parameter. To do this, the A value was measured by a neurotologist on the new OTOPLAN planning software and was validated to the one measured on the currently used DICOM viewer. Upon the validation of the OTOPLAN software, the other two cochlear parameters, namely width (B value) and height (H value) were measured, and CDL was automatically calculated. Finally, the correlation of all parameters with the CDL was statistically analyzed. MAIN OUTCOME MEASURES: Validation of OTOPLAN and CDL estimation. SAMPLE SIZE: 88 ears. RESULTS: There was no significant difference between the A-value measured on the DICOM viewing software and that on the new planning software by the two independent neurotologists (P=.27). Both Aand B-values showed a high positive correlation to the CDL. However, the B-value showed a stronger correlation to the CDL than the A-value (r=0.63 for A, and r=0.96 for B). CONCLUSION: The direct measurement of cochlea parameters and automatic calculation of the CDL could improve the efficiency of clinical workflow and make otology surgeons more independent. Moreover, the cochlear width (B) has a strong correlation to the CDL. Thus, we suggest using the combination of A and B to accurately estimate the CDL rather than using only one. LIMITATIONS: Single center and small sample size.
引用
收藏
页码:212 / 218
页数:7
相关论文
共 50 条
  • [41] COCHLEAR DUCT OF LIZARDS AND SNAKES
    MILLER, MR
    AMERICAN ZOOLOGIST, 1966, 6 (03): : 421 - &
  • [42] COCHLEAR DUCT LIZARDS AND SNAKES
    MILLER, MR
    ANATOMICAL RECORD, 1966, 154 (02): : 503 - &
  • [43] HISTOMORPHOLOGY OF THE COCHLEAR DUCT OF BUFFALO
    TIWARI, GP
    RAMKRISHNA, V
    INDIAN JOURNAL OF ANIMAL SCIENCES, 1990, 60 (11): : 1283 - 1289
  • [44] PHYSIOLOGICAL CHEMISTRY OF COCHLEAR DUCT
    THALMANN, R
    MARCUS, DC
    THALMANN, I
    ACTA OTO-LARYNGOLOGICA, 1981, 91 (5-6) : 535 - 540
  • [45] LONGITUDINAL DISTRIBUTION OF COCHLEAR MICROPHONICS INSIDE COCHLEAR DUCT (GUINEA PIG)
    HONRUBIA, V
    WARD, PH
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1968, 44 (04): : 951 - &
  • [46] Modiolar Proximity of Slim Modiolar Electrodes and Cochlear Duct Length: Correlation for Potential Basis of Customized Cochlear Implantation With Perimodiolar Electrodes
    Lee, Sang-Yeon
    Bae, Yun Jung
    Carandang, Marge
    Kim, Yoonjoong
    Han, Jin Hee
    Huh, Gene
    Song, Jae-Jin
    Koo, Ja-Won
    Lee, Jun Ho
    Ha Oh, Seung
    Choi, Byung Yoon
    EAR AND HEARING, 2021, 42 (02): : 323 - 333
  • [47] Interobserver variability of cochlear duct measurements in pediatric cochlear implant candidates
    Salkic, Almir
    Yildiz, Erdem
    Baumgartner, Wolf-Dieter
    Tokic, Lejla
    Uscuplic, Sabrina
    Sarihodzic, Senada
    Brkic, Fuad
    Harcinovic, Alen
    Liu, David T.
    Brkic, Faris F.
    EUROPEAN ARCHIVES OF OTO-RHINO-LARYNGOLOGY, 2023, 280 (04) : 1647 - 1651
  • [48] Interobserver variability of cochlear duct measurements in pediatric cochlear implant candidates
    Almir Salkic
    Erdem Yildiz
    Wolf-Dieter Baumgartner
    Lejla Tokic
    Sabrina Uscuplic
    Senada Sarihodzic
    Fuad Brkic
    Alen Harcinovic
    David T. Liu
    Faris F. Brkic
    European Archives of Oto-Rhino-Laryngology, 2023, 280 : 1647 - 1651
  • [49] How to predict cochlear length before cochlear implantation surgery
    Erixon, Elsa
    Rask-Andersen, Helge
    ACTA OTO-LARYNGOLOGICA, 2013, 133 (12) : 1258 - 1265
  • [50] Accuracy of Preoperative Cochlear Duct Length Estimation and Angular Insertion Depth Prediction
    Breitsprecher, Tabita
    Mlynski, Robert
    Voelter, Christiane
    Van de Heyning, Paul
    Van Rompaey, Vincent
    Dazert, Stefan
    Weiss, Nora M. M.
    OTOLOGY & NEUROTOLOGY, 2023, 44 (08) : E566 - E571