Direct measurement of cochlear parameters for automatic calculation of the cochlear duct length

被引:27
|
作者
Khurayzi, Tawfiq [1 ]
Almuhawas, Fida [1 ]
Sanosi, Abdulrahman [1 ]
机构
[1] King Saud Univ KSU, Coll Med, King Abdullah Ear Specialist Ctr KAESC, Dept Otolaryngol, Riyadh 11451, Saudi Arabia
关键词
DEEP ELECTRODE INSERTION; MORPHOLOGY; CORTI; ORGAN; RECONSTRUCTION; VARIABILITY; SIZE;
D O I
10.5144/0256-4947.2020.218
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BACKGROUND: Cochlear morphology and cochlear duct length (CDL) play important roles in the selection of appropriate electrodes. Cochlear parameters such as diameter (A value) and width (B value) are used as inputs for calculating the CDL. Current measurements of these parameters are inefficient and time consuming. Recently developed otological planning software (OTOPLAN) allows surgeons to directly measure these parameters and then automatically calculate the CDL. OBJECTIVES: The primary objective was to validate this new software for measuring the cochlear parameters and CDL. The secondary aim was to investigate the correlation between each cochlear parameter with the calculated CDL. DESIGN: Retrospective. SETTINGS: Ear specialist hospital. PATIENTS AND METHODS: The measurement of cochlear diameter (A value) was chosen as the validation parameter. To do this, the A value was measured by a neurotologist on the new OTOPLAN planning software and was validated to the one measured on the currently used DICOM viewer. Upon the validation of the OTOPLAN software, the other two cochlear parameters, namely width (B value) and height (H value) were measured, and CDL was automatically calculated. Finally, the correlation of all parameters with the CDL was statistically analyzed. MAIN OUTCOME MEASURES: Validation of OTOPLAN and CDL estimation. SAMPLE SIZE: 88 ears. RESULTS: There was no significant difference between the A-value measured on the DICOM viewing software and that on the new planning software by the two independent neurotologists (P=.27). Both Aand B-values showed a high positive correlation to the CDL. However, the B-value showed a stronger correlation to the CDL than the A-value (r=0.63 for A, and r=0.96 for B). CONCLUSION: The direct measurement of cochlea parameters and automatic calculation of the CDL could improve the efficiency of clinical workflow and make otology surgeons more independent. Moreover, the cochlear width (B) has a strong correlation to the CDL. Thus, we suggest using the combination of A and B to accurately estimate the CDL rather than using only one. LIMITATIONS: Single center and small sample size.
引用
收藏
页码:212 / 218
页数:7
相关论文
共 50 条
  • [21] Fully Automated Measurement of Cochlear Duct Length From Clinical Temporal Bone Computed Tomography
    Neves, Caio A.
    Tran, Emma D.
    Cooperman, Shayna P.
    Blevins, Nikolas H.
    LARYNGOSCOPE, 2022, 132 (02): : 449 - 458
  • [22] Cochlear duct length in Pakistani cochlear implant recipients gender, age and side association: A Radiological Measure
    Sarwar, Zahra
    Ahmed, Jawwad
    Saqulain, Ghulam
    Khan, Muhammad Iqbal Javed
    PAKISTAN JOURNAL OF MEDICAL SCIENCES, 2024, 40 (01) : 41 - 45
  • [23] Cochlear Duct Length Calculation: Comparison Between Using Otoplan and Curved Multiplanar Reconstruction in Nonmalformed Cochlea
    Chen, Ying
    Chen, Jianqing
    Tan, Haoyue
    Jiang, Mengda
    Wu, Yingwei
    Zhang, Zhihua
    Li, Yun
    Jia, Huan
    Wu, Hao
    OTOLOGY & NEUROTOLOGY, 2021, 42 (07) : E875 - E880
  • [24] Measuring Cochlear Duct Length - a historical analysis of methods and results
    Koch, Robert W.
    Ladak, Hanif M.
    Elfarnawany, Mai
    Agrawal, Sumit K.
    JOURNAL OF OTOLARYNGOLOGY-HEAD & NECK SURGERY, 2017, 46
  • [25] Measuring Cochlear Duct Length – a historical analysis of methods and results
    Robert W. Koch
    Hanif M. Ladak
    Mai Elfarnawany
    Sumit K. Agrawal
    Journal of Otolaryngology - Head & Neck Surgery, 46
  • [26] Cochlear duct length-one size fits all?
    Thong, J. F.
    Low, D.
    Tham, A.
    Liew, C.
    Tan, T. Y.
    Yuen, H. W.
    AMERICAN JOURNAL OF OTOLARYNGOLOGY, 2017, 38 (02) : 218 - 221
  • [27] ELECTROPHYSIOLOGY OF COCHLEAR DUCT
    BRUSILOW, SW
    FEDERATION PROCEEDINGS, 1972, 31 (02) : A298 - &
  • [28] CT-scan contouring technique allows for direct and reliable measurements of the cochlear duct length: implication in cochlear implantation with straight electrode-arrays
    Thi Hau Vu
    Perazzini, Chiara
    Puechmaille, Mathilde
    Bachy, Aurelie
    Mulliez, Aurelien
    Boyer, Louis
    Mom, Thierry
    Gabrillargues, Jean
    EUROPEAN ARCHIVES OF OTO-RHINO-LARYNGOLOGY, 2019, 276 (08) : 2135 - 2140
  • [29] CT-scan contouring technique allows for direct and reliable measurements of the cochlear duct length: implication in cochlear implantation with straight electrode-arrays
    Thi Hau Vu
    Chiara Perazzini
    Mathilde Puechmaille
    Aurélie Bachy
    Aurélien Mulliez
    Louis Boyer
    Thierry Mom
    Jean Gabrillargues
    European Archives of Oto-Rhino-Laryngology, 2019, 276 : 2135 - 2140
  • [30] Measuring the cochlea before implantation Regular determination of the cochlear duct length and specific measurement of the first turn
    Brill, Ioana T.
    LARYNGO-RHINO-OTOLOGIE, 2025, 104 (03) : 157 - 159