Two-dimensional Fourier transform ion cyclotron resonance mass spectrometry: reduction of scintillation noise using Cadzow data processing

被引:19
|
作者
van Agthoven, Maria A. [1 ]
Coutouly, Marie-Aude [2 ]
Rolando, Christian [1 ]
Delsuc, Marc-Andre [2 ,3 ,4 ]
机构
[1] Univ Lille 1, USR CNRS 3290, Inst Michel Eugene Chevreul, FR CNRS 2638,IFR 147, F-59655 Villeneuve Dascq, France
[2] NMRTEC, F-67400 Illkirch Graffenstaden, France
[3] Univ Strasbourg, Inst Genet & Biol Mol & Cellulaire, INSERM, U596, F-67404 Illkirch Graffenstaden, France
[4] Univ Strasbourg, UMR CNRS 7104, F-67404 Illkirch Graffenstaden, France
关键词
ELECTRON-CAPTURE DISSOCIATION; TWO-DIMENSIONAL NMR; HADAMARD-TRANSFORM; T(1) NOISE; ENHANCEMENT PROCEDURE; MAGNETRON MOTION; T1; NOISE; SPECTRA; SPECTROSCOPY; SUPPRESSION;
D O I
10.1002/rcm.5002
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
In two-dimensional Fourier transformion cyclotron resonance mass spectrometry (2D FTICR-MS), scintillation noise, caused mostly by fluctuations in the number of ions in the ICR cell, is the leading cause for errors in spectrum interpretation. In this study, we adapted an algorithm based on singular value decomposition and first introduced by Cadzow et al. (IEE Proceedings Pt. F 1987, 134, 69) to 2D FTICR-MS and we measured its performance in terms of noise reduction without losing signal information in the 2D mass spectrum. Copyright (C) 2011 John Wiley & Sons, Ltd.
引用
收藏
页码:1609 / 1616
页数:8
相关论文
共 50 条
  • [41] Molecular characterization of atmospheric particulates using Fourier transform ion cyclotron resonance mass spectrometry
    Hatcher, Patrick G.
    Sleighter, Rachel L.
    Willoughby, Amanda S.
    Mazzer, Paula A.
    Wozniak, Andrew S.
    Bauer, James E.
    GEOCHIMICA ET COSMOCHIMICA ACTA, 2009, 73 (13) : A501 - A501
  • [42] High-throughput proteomics using Fourier transform ion cyclotron resonance mass spectrometry
    Qian, WJ
    Camp, DG
    Smith, RD
    EXPERT REVIEW OF PROTEOMICS, 2004, 1 (01) : 87 - 95
  • [43] Determination of complicated surfactant components using Fourier transform ion cyclotron resonance mass spectrometry
    Xiong, SX
    Pu, D
    Bin, X
    Wang, GH
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2003, 31 (04) : 429 - 432
  • [44] FOURIER-TRANSFORM ION-CYCLOTRON RESONANCE MASS-SPECTROMETRY
    BAYKUT, G
    EYLER, JR
    TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 1986, 5 (02) : 44 - 49
  • [45] Internal glow discharge Fourier transform ion cyclotron resonance mass spectrometry
    Goodner, KL
    Milgram, KE
    Watson, CH
    Eyler, JR
    Dejsupa, C
    Barshick, CM
    JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1996, 7 (09) : 923 - 929
  • [46] Expanding frontiers of Fourier transform ion cyclotron resonance mass spectrometry.
    Marshall, AG
    Guan, SH
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1996, 211 : 115 - ANYL
  • [47] FOURIER-TRANSFORM ION-CYCLOTRON RESONANCE MASS-SPECTROMETRY
    MARSHALL, AG
    ACCOUNTS OF CHEMICAL RESEARCH, 1985, 18 (10) : 316 - 322
  • [48] Fourier-transform ion cyclotron resonance mass spectrometry for characterizing proteoforms
    Tucholski, Trisha
    Ge, Ying
    MASS SPECTROMETRY REVIEWS, 2022, 41 (02) : 158 - 177
  • [49] ION-CYCLOTRON RESONANCE - FOURIER-TRANSFORM MASS-SPECTROMETRY
    MAUGH, TH
    SCIENCE, 1977, 195 (4284) : 1314 - 1315
  • [50] Milestones in Fourier transform ion cyclotron resonance mass spectrometry technique development
    Marshall, AG
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2000, 200 (1-3) : 331 - 356