Comparison of electrospray LC-MS, LC-MS with Cold EI and GC-MS with Cold EI for sample identification

被引:25
|
作者
Tsizin, Svetlana [1 ]
Bokka, Ramesh [1 ]
Keshet, Uri [1 ]
Alon, Tal [1 ]
Fialkov, Alexander B. [1 ]
Tal, Noam [1 ]
Amirav, Aviv [1 ]
机构
[1] Tel Aviv Univ, Sch Chem, IL-69978 Tel Aviv, Israel
基金
以色列科学基金会;
关键词
ESI-LC-MS; Electron ionization LC-MS; LC-MS with Cold EI; GC-MS with Cold EI; Supersonic molecular beams; SUPERSONIC MOLECULAR-BEAMS; CHROMATOGRAPHY-MASS-SPECTROMETRY; ATMOSPHERIC-PRESSURE PHOTOIONIZATION; ION-SOURCE; IONIZATION; INTERFACE;
D O I
10.1016/j.ijms.2017.09.006
中图分类号
O64 [物理化学(理论化学)、化学物理学]; O56 [分子物理学、原子物理学];
学科分类号
070203 ; 070304 ; 081704 ; 1406 ;
摘要
Electrospray LC-MS, LC-MS with Cold EI and GC-MS with Cold EI (Electron Ionization (EI) of vibrationally cold molecules in supersonic molecular beams (SMB)) are compared in their sample identification capabilities. Two test mixtures were used: (a) acetaminophen, caffeine, sulfadimethoxine, terfenadine and reserpine; and (b) octafluoronaphthalene (OFN), pyrene, cholesterol and agidol 40. The major strength of EI in both LC-MS with Cold EI and GC-MS with Cold EI is its compatibility with library based sample identification that provides samples names and structures at the isomer level. GC-MS with Cold EI alleviates two majordownsides of GC-MS with standard EI as it provides enhanced molecular ions that are often weak or missing in standard EI and, it significantly extends the range of compounds that are amenable for analysis. Consequently, reserpine and agidol 40 that are incompatible with standard GC-MS analyses are analyzed by GC-MS with Cold EI and yield effective library based identification. In cases involving sample compounds that are not in the library, ESI-LC-MS provides elemental formula information (when combined with high resolution MS) while GC-MS with Cold EI also provides elemental formula when TAMI software is used for the quadrupole mass accuracy improvement combined with isotope abundance analysis. We found that both LC-MS with Cold EI and GC-MS with Cold EI have broader range of small molecules amenable for analysis than ESI-LC-MS that fails to analyze relatively non-polar compounds and exhibits highly non-uniform and compound dependent ionization yields that span over four orders of magnitude. The total ion mass chromatograms S/N of ESI-LC-MS and LC-MS with Cold EI are comparable while it is better (>100 times per on-column amount) for GC-MS with Cold EI. (C) 2017 Elsevier B.V. All rights reserved.
引用
收藏
页码:119 / 125
页数:7
相关论文
共 50 条
  • [1] Quantitative electrospray LC-MS and LC-MS/MS in biomedicine
    Carrascal, M
    Schneider, K
    Calaf, RE
    van Leeuwen, S
    Canosa, D
    Gelpí, E
    Abian, J
    [J]. JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1998, 17 (6-7) : 1129 - 1138
  • [2] Analysis of neurosterols by GC-MS and LC-MS/MS
    Griffiths, William J.
    Wang, Yuqin
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2009, 877 (26): : 2778 - 2805
  • [3] The best MS option: GC-MS and LC-MS
    Sheehan, TL
    [J]. AMERICAN LABORATORY, 2002, 34 (18) : 40 - +
  • [4] LC-MS/MS AND GC-MS(/MS) BASED STEROIDOMICS
    Wudy, S. A.
    Sanchez-Guijo, A.
    Hartmann, M. F.
    [J]. REPRODUCTION IN DOMESTIC ANIMALS, 2014, 49 : 47 - 47
  • [5] Electron ionization in LC-MS: recent developments and applications of the direct-EI LC-MS interface
    Pierangela Palma
    Giorgio Famiglini
    Helga Trufelli
    Elisabetta Pierini
    Veronica Termopoli
    Achille Cappiello
    [J]. Analytical and Bioanalytical Chemistry, 2011, 399 : 2683 - 2693
  • [6] Electron ionization in LC-MS: recent developments and applications of the direct-EI LC-MS interface
    Palma, Pierangela
    Famiglini, Giorgio
    Trufelli, Helga
    Pierini, Elisabetta
    Termopoli, Veronica
    Cappiello, Achille
    [J]. ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2011, 399 (08) : 2683 - 2693
  • [7] Identification of polymer additives using a combination of GC-MS and LC-MS
    Roy, J
    Binkley, J
    [J]. LC GC NORTH AMERICA, 2002, : 41 - 41
  • [8] Phytochemical analysis in Alternanthera brasiliana by LC-MS/MS and GC-MS
    de Alencar Filho, Jose M. T.
    Teixeira, Hyany A. P.
    Sampaio, Pedrita A.
    Pereira, Emanuella C. V.
    e Amariz, Isabela A.
    Rolim Neto, Pedro J.
    Rolim, Larissa A.
    da Cruz Araujo, Edigenia C.
    [J]. NATURAL PRODUCT RESEARCH, 2020, 34 (03) : 429 - 433
  • [9] Identification of losartan degradates in stressed tablets by LC-MS and LC-MS/MS
    Zhao, ZX
    Wang, QX
    Tsai, EW
    Qin, XZ
    Ip, D
    [J]. JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1999, 20 (1-2) : 129 - 136
  • [10] Fast saliva analysis by GC-MS with Cold EI and Open Probe Fast GC-MS with Cold EI for the detection of cannabis usage
    Elkabets, Oneg
    Neumark, Benny
    Amirav, Aviv
    [J]. JOURNAL OF MASS SPECTROMETRY, 2023, 58 (12):