Electron ionization in LC-MS: recent developments and applications of the direct-EI LC-MS interface

被引:40
|
作者
Palma, Pierangela [1 ]
Famiglini, Giorgio [1 ]
Trufelli, Helga [1 ]
Pierini, Elisabetta [1 ]
Termopoli, Veronica [1 ]
Cappiello, Achille [1 ]
机构
[1] Univ Urbino, Lab LC MS, Dipartimento GeoTeCA, I-61029 Urbino, Italy
关键词
Nano liquid chromatography; Mass spectrometry; Electron ionization; CHROMATOGRAPHY-MASS-SPECTROMETRY; BASIC-NEUTRAL PESTICIDES; PARTICLE-BEAM INTERFACE; ELUENT-JET INTERFACE; LIQUID-CHROMATOGRAPHY; LC/MS; WATER; PERFORMANCE; ORGANOCHLORINE; SUPPRESSION;
D O I
10.1007/s00216-010-4637-0
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The purpose of this article is to underline the possibility of efficiently using electron ionization (EI) in liquid chromatography (LC) and mass spectrometry (MS). From a historical perspective, EI accompanied the first attempts in LC-MS but, owing to several technical shortcomings, it was soon outshined by soft, atmospheric pressure ionization (API) techniques. Nowadays, two modern approaches, supersonic molecular beam LC-MS and direct-EI LC-MS, offer a valid alterative to API, and preserve the advantages of EI also in LC-MS applications. These advantages can be summarized in three crucial aspects: automated library identification; identification of unknown compounds, owing to EI extensive fragment information; inertness to coeluted matrix interferences owing to very unlikely ion-ion and ion-molecule interactions in the EI gas-phase environment. The direct-EI LC-MS interface is a simple and efficient solution able to produce high-quality, interpretable EI spectra from a wide range of low molecular weight molecules of different polarity. Because of the low operative flow rates, this interface relies on a nano-LC technology that helps in reducing the impact of the mobile phase on the gas-phase environment of EI. This review provides an extensive discussion on the role of EI in LC-MS interfacing, and presents in detail several performance aspects of the direct-EI LC-MS interface, especially in terms of response, mass-spectral quality, and matrix effects. In addition, several key applications are also reported.
引用
下载
收藏
页码:2683 / 2693
页数:11
相关论文
共 50 条
  • [1] Electron ionization in LC-MS: recent developments and applications of the direct-EI LC-MS interface
    Pierangela Palma
    Giorgio Famiglini
    Helga Trufelli
    Elisabetta Pierini
    Veronica Termopoli
    Achille Cappiello
    Analytical and Bioanalytical Chemistry, 2011, 399 : 2683 - 2693
  • [2] Toward a Universal Detector for Small Molecule Applications: Direct-EI in LC-MS
    Palma, Pierangela
    Famiglini, Giorgio
    Trufelli, Helga
    Cappiello, Achille
    LC GC NORTH AMERICA, 2011, 29 (01) : 68 - 75
  • [3] DIRECT-EI IN LC-MS: TOWARDS A UNIVERSAL DETECTOR FOR SMALL-MOLECULE APPLICATIONS
    Cappiello, Achille
    Famiglini, Giorgio
    Palma, Pierangela
    Pierini, Elisabetta
    Termopoli, Veronica
    Trufelli, Helga
    MASS SPECTROMETRY REVIEWS, 2011, 30 (06) : 1242 - 1255
  • [4] Comparison of electrospray LC-MS, LC-MS with Cold EI and GC-MS with Cold EI for sample identification
    Tsizin, Svetlana
    Bokka, Ramesh
    Keshet, Uri
    Alon, Tal
    Fialkov, Alexander B.
    Tal, Noam
    Amirav, Aviv
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2017, 422 : 119 - 125
  • [5] Quantitative electrospray LC-MS and LC-MS/MS in biomedicine
    Carrascal, M
    Schneider, K
    Calaf, RE
    van Leeuwen, S
    Canosa, D
    Gelpí, E
    Abian, J
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1998, 17 (6-7) : 1129 - 1138
  • [6] INVESTIGATION OF AN LC-MS INTERFACE FOR EI-IONIZATION, CI-IONIZATION AND FAB-IONIZATION
    DOBBERSTEIN, P
    KORTE, E
    MEYERHOFF, G
    PESCH, R
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1983, 46 (JAN): : 185 - 188
  • [7] In electrospray ionization source hydrogen/deuterium exchange LC-MS and LC-MS/MS for characterization of metabolites
    Lam, W
    Ramanathan, R
    JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2002, 13 (04) : 345 - 353
  • [8] Tips for Electrospray Ionization LC-MS
    Taylor, Tony
    LC GC NORTH AMERICA, 2021, 39 (01) : 42 - 42
  • [9] LC-MS and LC-MS/MS analysis of saponins and sapogenins - comparison of ionization techniques and their usefulness in compound identification
    Muir, AD
    Ballantyne, KD
    Hall, TW
    SAPONINS IN FOOD, FEEDSTUFFS AND MEDICINAL PLANTS, 2000, 45 : 35 - 41
  • [10] Determination of penicillins in milk using LC-UV, LC-MS and LC-MS/MS
    Martinez-Huelamo, Miriam
    Jimenez-Gamez, Esther
    Pilar Hermo, Maria
    Barron, Dolores
    Barbosa, Jose
    JOURNAL OF SEPARATION SCIENCE, 2009, 32 (14) : 2385 - 2393