Electron ionization in LC-MS: recent developments and applications of the direct-EI LC-MS interface

被引:40
|
作者
Palma, Pierangela [1 ]
Famiglini, Giorgio [1 ]
Trufelli, Helga [1 ]
Pierini, Elisabetta [1 ]
Termopoli, Veronica [1 ]
Cappiello, Achille [1 ]
机构
[1] Univ Urbino, Lab LC MS, Dipartimento GeoTeCA, I-61029 Urbino, Italy
关键词
Nano liquid chromatography; Mass spectrometry; Electron ionization; CHROMATOGRAPHY-MASS-SPECTROMETRY; BASIC-NEUTRAL PESTICIDES; PARTICLE-BEAM INTERFACE; ELUENT-JET INTERFACE; LIQUID-CHROMATOGRAPHY; LC/MS; WATER; PERFORMANCE; ORGANOCHLORINE; SUPPRESSION;
D O I
10.1007/s00216-010-4637-0
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The purpose of this article is to underline the possibility of efficiently using electron ionization (EI) in liquid chromatography (LC) and mass spectrometry (MS). From a historical perspective, EI accompanied the first attempts in LC-MS but, owing to several technical shortcomings, it was soon outshined by soft, atmospheric pressure ionization (API) techniques. Nowadays, two modern approaches, supersonic molecular beam LC-MS and direct-EI LC-MS, offer a valid alterative to API, and preserve the advantages of EI also in LC-MS applications. These advantages can be summarized in three crucial aspects: automated library identification; identification of unknown compounds, owing to EI extensive fragment information; inertness to coeluted matrix interferences owing to very unlikely ion-ion and ion-molecule interactions in the EI gas-phase environment. The direct-EI LC-MS interface is a simple and efficient solution able to produce high-quality, interpretable EI spectra from a wide range of low molecular weight molecules of different polarity. Because of the low operative flow rates, this interface relies on a nano-LC technology that helps in reducing the impact of the mobile phase on the gas-phase environment of EI. This review provides an extensive discussion on the role of EI in LC-MS interfacing, and presents in detail several performance aspects of the direct-EI LC-MS interface, especially in terms of response, mass-spectral quality, and matrix effects. In addition, several key applications are also reported.
引用
下载
收藏
页码:2683 / 2693
页数:11
相关论文
共 50 条
  • [21] Current developments in LC-MS for pharmaceutical analysis
    Beccaria, Marco
    Cabooter, Deirdre
    ANALYST, 2020, 145 (04) : 1129 - 1157
  • [22] APPLICATIONS OF LC-MS/MS IN BIOMEDICAL AND PLANT STUDIES
    Wang, S.
    CLINICAL AND EXPERIMENTAL PHARMACOLOGY AND PHYSIOLOGY, 2013, 40 : 41 - 41
  • [23] Current developments in LC-MS for pharmaceutical analysis
    Lim, CK
    Lord, G
    BIOLOGICAL & PHARMACEUTICAL BULLETIN, 2002, 25 (05) : 547 - 557
  • [24] Profiling eicosanoids and phospholipids using LC-MS/MS: Principles and recent applications
    Ecker, Josef
    JOURNAL OF SEPARATION SCIENCE, 2012, 35 (10-11) : 1227 - 1235
  • [25] Buffers for LC-MS
    Neue, UD
    AMERICAN LABORATORY, 2001, 33 (22) : 51 - 51
  • [26] LC-MS COUPLING
    ARPINO, PJ
    GUIOCHON, G
    ANALYTICAL CHEMISTRY, 1979, 51 (07) : A682 - &
  • [27] Buffer Considerations for LC and LC-MS
    Subirats, Xavier
    Bosch, Elisabeth
    Roses, Marti
    LC GC NORTH AMERICA, 2009, 27 (11) : 1000 - 1004
  • [28] Not (Only) Reversed-Phase LC-MS: Alternative LC-MS Approaches
    Kohler, Isabelle
    Sun, Mingzhe
    Groeneveld, Gino
    Gargano, Andrea F. G.
    LC GC EUROPE, 2020, 33 (11) : 544 - 558
  • [29] Not (Only) Reversed-Phase LC-MS: Alternative LC-MS Approaches
    Kohler, Isabelle
    Sun, Mingzhe
    Groeneveld, Gino
    Gargano, Andrea F. G.
    LC GC NORTH AMERICA, 2020, 38 (09) : 507 - 518
  • [30] Chromatographic alignment of LC-MS and LC-MS/MS datasets by genetic algorithm feature extraction
    Palmblad, Magnus
    Mills, Davinia J.
    Bindschedler, Laurence V.
    Cramer, Rainer
    JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2007, 18 (10) : 1835 - 1843