Quantitative analysis of Δ9-tetrahydrocannabinol in preserved oral fluid by liquid chromatography-tandem mass spectrometry

被引:47
|
作者
Laloup, M
Fernandez, MDR
Wood, M
De Boeck, G
Henquet, U
Maes, V
Samyn, N
机构
[1] NICC, Sect Toxicol, B-1120 Brussels, Belgium
[2] MS Technol Ctr, Waters Corp, Manchester, Lancs, England
[3] Maastricht Univ, Dept Psychiat & Neuropsychol, EURON, S Limburg Mental Hlth Res & Teaching Network, Maastricht, Netherlands
[4] Free Univ Brussels, Dept Clin Chem Toxicol, Acad Hosp, Brussels, Belgium
关键词
LC-MS-MS; oral fluids; THC;
D O I
10.1016/j.chroma.2005.03.031
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A rapid and sensitive method for the analysis of Delta(9)-tetrahydrocannabinol (THC) in preserved oral fluid was developed and fully validated. Oral fluid was collected with the Intercept, a Food and Drug Administration (FDA) approved sampling device that is used on a large scale in the U.S. for workplace drug testing. The method comprised a simple liquid-liquid extraction with hexane, followed by liquid chromatography-tandem mass spectrometry (LC-MS-MS) analysis. Chromatographic separation was achieved using a XTerra MS C-18 column, eluted isocratically with 1 mM ammonium formate-methanol (10:90, v/v). Selectivity of the method was achieved by a combination of retention time, and two precursor-product ion transitions. The use of the liquid-liquid extraction was demonstrated to be highly effective and led to significant decreases in the interferences present in the matrix. Validation of the method was performed using both 100 and 500 mu L of oral fluid. The method was linear over the range investigated (0.5-100 ng/mL and 0.1-10 ng/mL when 100 and 500 mu L, respectively, of oral fluid were used) with an excellent intra-assay and inter-assay precision (relative standard deviations, RSD < 6%) for quality control samples spiked at a concentration of 2.5 and 25 ng/mL and 0.5 and 2.5 ng/mL, respectively. Limits of quantification were 0.5 and 0.1 ng/mL when using 100 and 500 mu L, respectively. In contrast to existing GC-MS methods, no extensive sample clean-up and time-consuming derivatisation steps were needed. The method was subsequently applied to Intercept samples collected at the roadside and collected during a controlled study with cannabis. (c) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:15 / 24
页数:10
相关论文
共 50 条
  • [41] Simple protein precipitation-based analysis of Δ9-tetrahydrocannabinol and its metabolites in human serum by liquid chromatography–tandem mass spectrometry
    Marek Dziadosz
    Michael Klintschar
    Jörg Teske
    Forensic Toxicology, 2017, 35 : 190 - 194
  • [42] Quantitative analysis of glycerol levels in human urine by liquid chromatography-tandem mass spectrometry
    Dong, Ying
    Ma, Yanhua
    Yan, Kuan
    Shen, Li
    Wang, Xiaobing
    Xu, Youxuan
    He, Genye
    Wu, Yun
    Lu, Jianghai
    Yang, Zhiyong
    Feng, Feifei
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2014, 957 : 30 - 35
  • [43] Method Validation for Quantitative Analysis of Metribuzin in Wheat by Liquid Chromatography-Tandem Mass Spectrometry
    Hazra, Dipak Kumar
    Purkait, Aloke
    Raghuwanshi, Durgesh
    Murthy, K. Sri Rama
    JOURNAL OF CHROMATOGRAPHIC SCIENCE, 2021, 59 (01) : 47 - 54
  • [44] Quantitative analysis of amphiphilic N-alkyloxypyridinecarboximidamide by liquid chromatography-tandem mass spectrometry
    Wojciechowska, Irmina
    Wojciechowska, Aleksandra
    Wieszczycka, Karolina
    Aksamitowski, Przemyslaw
    Zembrzuska, Joanna
    Framski, Grzegorz
    CHEMICAL PAPERS, 2017, 71 (05): : 953 - 960
  • [45] Supercritical fluid chromatography-tandem mass spectrometry for the analysis of lipid A
    Chen, Yibai
    Lehotay, Steven J.
    Moreau, Robert A.
    ANALYTICAL METHODS, 2013, 5 (23) : 6864 - 6869
  • [46] A Rapid Quantitative Method for the Analysis of Synthetic Cannabinoids by Liquid Chromatography-Tandem Mass Spectrometry
    Freijo, Tom D., Jr.
    Harris, Steve E.
    Kala, Subbarao V.
    JOURNAL OF ANALYTICAL TOXICOLOGY, 2014, 38 (08) : 466 - 478
  • [47] Development of a Chiral Supercritical Fluid Chromatography-Tandem Mass Spectrometry and Reversed-Phase Liquid Chromatography-Tandem Mass Spectrometry Platform for the Quantitative Metabolic Profiling of Octadecanoid Oxylipins
    Quaranta, Alessandro
    Zohrer, Benedikt
    Revol-Cavalier, Johanna
    Benkestock, Kurt
    Balas, Laurence
    Oger, Camille
    Keyes, Gregory S.
    Wheelock, Asa M.
    Durand, Thierry
    Galano, Jean-Marie
    Ramsden, Christopher E.
    Hamberg, Mats
    Wheelock, Craig E.
    ANALYTICAL CHEMISTRY, 2022, 94 (42) : 14618 - 14626
  • [48] Liquid chromatography-tandem mass spectrometry analysis for azaspiracids and their metabolites
    Wu Haiyan
    Guo Mengmeng
    Zhao Chunxia
    Tan Zhijun
    Gu Haifeng
    Zhai Yuxiu
    Lu Lina
    CHINESE JOURNAL OF CHROMATOGRAPHY, 2016, 34 (04) : 401 - 406
  • [49] Analysis of RNA modifications by liquid chromatography-tandem mass spectrometry
    Thuering, Kathrin
    Schmid, Katharina
    Keller, Patrick
    Helm, Mark
    METHODS, 2016, 107 : 48 - 56
  • [50] Flavonoid Profiling Analysis by Liquid Chromatography-Tandem Mass Spectrometry
    Min, Jeuk
    Seo, Chan
    Park, Hyung-Jin
    Kim, Youngbae
    Lee, Hyeon-Seong
    Ji, Moongi
    Choi, Subin
    Oh, Songjin
    Park, Kyung-Wuk
    Paik, Man-Jeong
    BULLETIN OF THE KOREAN CHEMICAL SOCIETY, 2019, 40 (12) : 1162 - 1166