A portable and antibody-free sandwich assay for determination of chloramphenicol in food based on a personal glucose meter

被引:27
|
作者
Chen, Si [1 ]
Gan, Ning [2 ]
Zhang, Huairong [2 ]
Hu, Futao [1 ]
Li, Tianhua [2 ]
Cui, Huan [2 ]
Cao, Yuting [2 ]
Jiang, Qianli [3 ]
机构
[1] Ningbo Univ, Fac Marine Sci, Ningbo 315211, Zhejiang, Peoples R China
[2] Ningbo Univ, State Key Lab Base Novel Funct Mat & Preparat Sci, Fac Mat Sci & Chem Engn, Ningbo 315211, Zhejiang, Peoples R China
[3] Southern Med Univ, Dept Hematol, Nanfang Hosp, Guangzhou 510515, Guangdong, Peoples R China
基金
中国国家自然科学基金;
关键词
Chloramphenicol; Antibody-free; Sandwich-type assay; Molecularly imprinted; beta-Cyclodextrin; Personal glucose meter; MOLECULARLY IMPRINTED POLYMER; QUARTZ-CRYSTAL MICROBALANCE; ELECTROCHEMICAL IMMUNOASSAY; QUANTITATIVE DETECTION; SIGNAL AMPLIFICATION; MILK; NITROPHENOL; EXTRACTION; SEPARATION; READOUT;
D O I
10.1007/s00216-015-8478-8
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A portable and antibody-free sandwich assay was fabricated for determination of chloramphenicol (CAP) in animal-derived food by a personal glucose meter (PGM). The sandwich-type strategy was developed on the basis of magnetic molecularly imprinted probe (m-MIP) nanoparticles and a beta-cyclodextrin/invertase-functionalized signal tag. Firstly, the m-MIPs were fabricated using polydopamine molecularly imprinted film modified Fe3O4 nanoparticles with 2, 2-dichloroacetamide as a template that could capture the 2,2-dichloroacetamide segment of CAP. Secondly, beta-cyclodextrin/invertase polymer bioconjungate was synthesized as a signal tag that could recognize the nitrobenzene segment of CAP through host-guest interaction. The dual-specificity recognition model relies on the formation of a sandwich between m-MIPs, different segments of CAP, and the beta-cyclodextrin-functionalized signal tag. The sandwich-type complex formed was then subjected to detection with a PGM. The complexes can hydrolyze sucrose to glucose, which can be used for detection with a PGM through invertase. According to our experiment, the concentration of CAP was proportional to the amount of glucose formed, which could quantitatively assess the CAP with a dynamic range of 0.5-50 ng mL(-1) and a detection limit of 0.16 ng mL(-1) (signal-to-noise ratio of 3). The detection time of the assay was about 1 h, which was obviously shorter than that of competitive ELISA. More importantly, we have successfully applied this on-site assay for CAP screening in animal-derived food.
引用
收藏
页码:2499 / 2507
页数:9
相关论文
共 50 条
  • [21] Recent Advances in Personal Glucose Meter-Based Biosensors for Food Safety Hazard Detection
    Wang, Su
    Huang, Huixian
    Wang, Xin
    Zhou, Ziqi
    Luo, Yunbo
    Huang, Kunlun
    Cheng, Nan
    FOODS, 2023, 12 (21)
  • [22] Integrated enzyme with stimuli-responsive coordination polymer for personal glucose meter-based portable immunoassay
    Gao, Liping
    Li, Yong
    Huang, Zhen-Zhong
    Tan, Hongliang
    ANALYTICA CHIMICA ACTA, 2022, 1207
  • [23] Portable Aptasensor of Aflatoxin B1 in Bread Based on a Personal Glucose Meter and DNA Walking Machine
    Yang, Xinsheng
    Shi, Dongmin
    Zhu, Shengmei
    Wang, Baojuan
    Zhang, Xiaojun
    Wang, Guangfeng
    ACS SENSORS, 2018, 3 (07): : 1368 - 1375
  • [24] Antibody-free lanthanide-based fluorescent probe for determination of protein tyrosine kinase and phosphatase activities
    Heidi Appelblom
    Aura Sipponen
    Antti Valanne
    Tero Soukka
    Timo Lövgren
    Pauliina Niemelä
    Microchimica Acta, 2011, 172 : 25 - 29
  • [25] A portable and efficient strategy for ofloxacin detection using Ce-based MOF-loaded glucose oxidase and a personal glucose meter
    Wang, Qianqian
    He, Baoshan
    Liu, Yao
    Wu, Ligen
    Zhao, Wenhong
    Xie, Dongdong
    Ren, Wenjie
    Xu, Yiwei
    ANALYTICA CHIMICA ACTA, 2025, 1351
  • [26] Portable and quantitative point-of-care monitoring of Escherichia coli O157:H7 using a personal glucose meter based on immunochromatographic assay
    Huang, Haoran
    Zhao, Guangying
    Dou, Wenchao
    BIOSENSORS & BIOELECTRONICS, 2018, 107 : 266 - 271
  • [27] Portable Detection of Melamine in Milk Using a Personal Glucose Meter Based on an in Vitro Selected Structure-Switching Aptamer
    Gu, Chunmei
    Lan, Tian
    Shi, Hanchang
    Lu, Yi
    ANALYTICAL CHEMISTRY, 2015, 87 (15) : 7676 - 7682
  • [28] Enzyme-Encapsulated Liposome-Linked Immunosorbent Assay Enabling Sensitive Personal Glucose Meter Readout for Portable Detection of Disease Biomarkers
    Lin, Bingqian
    Liu, Dan
    Yan, Jinmao
    Qiao, Zhi
    Zhong, Yunxin
    Yan, Jiawei
    Zhu, Zhi
    Ji, Tianhai
    Yang, Chaoyong James
    ACS APPLIED MATERIALS & INTERFACES, 2016, 8 (11) : 6890 - 6897
  • [29] Reference antigen-free and antibody-free LTD-IDMS assay for influenza H7N9 vaccine in vitro potency determination
    Morgenstern, Keith
    Xie, Yuhong
    Palladino, Giuseppe
    Barr, John R.
    Settembre, Ethan C.
    Williams, Tracie L.
    Wen, Yingxia
    VACCINE, 2018, 36 (41) : 6144 - 6151
  • [30] CRISPR/Cas12a system responsive DNA hydrogel for label-free detection of non-glucose targets with a portable personal glucose meter
    Ma, Wenxiao
    Liu, Minghui
    Xie, Shupu
    Liu, Bo
    Jiang, Lizhi
    Zhang, Xiaoru
    Yuan, Xunyi
    ANALYTICA CHIMICA ACTA, 2022, 1231