Enhanced sensitivity of a surface plasmon resonance biosensor using hyperbolic metamaterial and monolayer graphene

被引:14
|
作者
Gao, Jinjuan [1 ]
Zu, Qun [2 ]
Xu, Shicai [3 ]
Yang, Wen [4 ]
Feng, Jingwen [1 ]
Liu, Runcheng [1 ]
Zha, Zhipeng [1 ]
Peng, Qianqian [1 ]
Yue, Weiwei [1 ]
Huo, Yanyan [1 ]
Jiang, Shouzhen [1 ]
Fan, Xiuwei [1 ]
机构
[1] Shandong Normal Univ, Sch Phys & Elect, Collaborat Innovat Ctr Light Manipulat & Applicat, Jinan 250014, Peoples R China
[2] Qilu Normal Univ, Jinan 250200, Peoples R China
[3] Dezhou Univ, Inst Biophys, Shandong Key Lab Biophys, Dezhou 253023, Peoples R China
[4] Shandong Univ, Sch Control Sci & Engn, Jingshi Rd, Jinan 250061, Peoples R China
来源
OPTICS EXPRESS | 2021年 / 29卷 / 26期
基金
中国国家自然科学基金;
关键词
PLASTIC OPTICAL-FIBERS; HIGH-PERFORMANCE; SPR; SENSOR; PLATFORM;
D O I
10.1364/OE.447107
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
The presence of hyperbolic metamaterial (HMM) enables the coupling of surface plasmon polaritons (SPPs) and thus enhances the sensitivity of surface plasmon resonance (SPR) sensors. Biosensors based on the combination of HMM and two-dimensional materials possess the ability to further promote the detection sensitivity. In this paper, a monolayer graphene/HMM/D-shaped plastic optic fiber (G/HMM/D-POF) SPR sensor is proposed in the combination of the virtues of monolayer graphene, HMM, and D-POF. The sensing performance of the sensor has been proved by the numerical simulation and the experimental results. The optimal sensor structure is G/3*(Au/Al2O3)/D-POF, with a high sensitivity of 5166.7 nm/RIU for the detection of aqueous ethanol. Besides, glucose monitoring is essential for the detection and treatment of diabetes. Therefore, the G/3*(Au/Al2O3)/D-POF sensor is also used to detect aqueous glucose and achieve the sensitivity of 2767.3 nm/RIU. It is believed that the G/HMM/D-POF SPR sensor has the potential to provide a new detection path for biomolecule detection. (C) 2021 Optica Publishing Group under the terms of the Optica Open Access Publishing Agreement
引用
收藏
页码:43766 / 43777
页数:12
相关论文
共 50 条
  • [41] Split ring Resonator and thin wire metamaterial-based Graphene Surface Plasmon Resonance Biosensor Design with Optimized Physical Parameters and high Sensitivity
    Almawgani, Abdulkarem H. M.
    Patel, Shobhit K.
    Alzahrani, Ahmad
    Armghan, Ammar
    PLASMONICS, 2024, : 1603 - 1615
  • [42] Graphene-based Surface Plasmon Resonance Urea Biosensor using Kretschmann configuration
    Jamil, Nur Akmar
    Menon, P. Susthitha
    Said, Fairus Atida
    Tarumaraja, Kalaivani A.
    Mei, Gan Siew
    Majlis, Burhanuddin Yeop
    PROCEEDINGS OF THE 2017 IEEE REGIONAL SYMPOSIUM ON MICRO AND NANOELECTRONICS (RSM), 2017, : 112 - 115
  • [43] Graphene/Graphene Oxide-Based Ultrasensitive Surface Plasmon Resonance Biosensor
    Meshginqalam, Bahar
    Ahmadi, Mohammad Taghi
    Ismail, Razali
    Sabatyan, Arash
    PLASMONICS, 2017, 12 (06) : 1991 - 1997
  • [44] Ultrasensitive Surface Plasmon Resonance Biosensor Using Blue Phosphorus-Graphene Architecture
    Li, Keyi
    Li, Lintong
    Xu, Nanlin
    Peng, Xiao
    Zhou, Yingxin
    Yuan, Yufeng
    Song, Jun
    Qu, Junle
    SENSORS, 2020, 20 (11) : 1 - 13
  • [45] Graphene/Graphene Oxide-Based Ultrasensitive Surface Plasmon Resonance Biosensor
    Bahar Meshginqalam
    Mohammad Taghi Ahmadi
    Razali Ismail
    Arash Sabatyan
    Plasmonics, 2017, 12 : 1991 - 1997
  • [46] Sensitivity analysis of graphene multilayer based surface plasmon resonance biosensor in the ultraviolet, visible and infrared regions
    Shujing Chen
    Chengyou Lin
    Applied Physics A, 2019, 125
  • [47] Sensitivity enhancement by air mediated graphene multilayer based surface plasmon resonance biosensor for near infrared
    Maharana, Pradeep Kumar
    Jha, Rajan
    Palei, Srikanta
    SENSORS AND ACTUATORS B-CHEMICAL, 2014, 190 : 494 - 501
  • [48] Sensitivity analysis of graphene multilayer based surface plasmon resonance biosensor in the ultraviolet, visible and infrared regions
    Chen, Shujing
    Lin, Chengyou
    APPLIED PHYSICS A-MATERIALS SCIENCE & PROCESSING, 2019, 125 (04):
  • [49] Sensitivity comparison of graphene based surface plasmon resonance biosensor with Au, Ag and Cu in the visible region
    Chen, Shujing
    Lin, Chengyou
    MATERIALS RESEARCH EXPRESS, 2019, 6 (05)
  • [50] Lifetime of Enhanced Graphene Surface Plasmon and Superstrate Sensitivity
    Yang, Sa
    Zhou, Renlong
    Liu, Dan
    Lin, Qiawu
    Li, Shuang
    PLASMONICS, 2020, 15 (04) : 1103 - 1113