A Shoe-Integrated Sensor System for Long- Term Center of Pressure Evaluation

被引:13
|
作者
Guo, Rui [1 ]
Cheng, Xiang [2 ]
Hou, Zong-Chen [3 ,4 ]
Ma, Jing-Zhong [1 ]
Zheng, Wen-Qiang [5 ]
Wu, Xiao-Ming [1 ]
Jiang, Dong [3 ,4 ]
Pan, Yu [2 ]
Ren, Tian-Ling [1 ]
机构
[1] Tsinghua Univ, Beijing Natl Res Ctr Informat Sci & Technol BNRis, Sch Integrated Circuits, Beijing 100084, Peoples R China
[2] Tsinghua Changgung Hosp, Dept Phys Med & Rehabil, Beijing 102218, Peoples R China
[3] Peking Univ, Hosp 3, Dept Sports Med, Beijing 100191, Peoples R China
[4] Peking Univ, Inst Sports Med, Beijing 100191, Peoples R China
[5] Fuzhou Inst Data Technol, Fuzhou 350200, Peoples R China
基金
北京市自然科学基金;
关键词
Sensors; Foot; Monitoring; Hardware; Force; Diseases; Bluetooth; Activity recognition; center of pressure (CoP); plantar pressure; smart insole; static postural control; QUANTIFICATION;
D O I
10.1109/JSEN.2021.3116249
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In clinical, the center of pressure (CoP) is commonly used for accessing the stability of a person's postural control, which is highly associated with various neurological diseases and movement disorders such as Alzheimer's disease, Parkinson's disease, chronic ankle instability. Such a disease usually has a long development or rehabilitation process which requires long-term CoP monitoring. The current CoP evaluation process does not meet the requirement, as it is often complicated and expensive through either the lab-based equipment or the clinical evaluation procedure. Different wearable sensor-based systems with less cost and restrictions have emerged, but their way of CoP calculation requires deliberate calibration of the positions of their sensors, which are not feasible in daily CoP monitoring. In this study, we developed a long-term CoP monitoring system in a smart-shoe form. First, a thin and flexible smart insole with optimal sensor locations was designed to be compact and energy sufficient for a whole-day usage. Then, a user-friendly app on the smartphone with a cloud-based data managing system was developed for applications in both clinical and home environments. Additionally, a simplified CoP estimation model was created without the need for calibration. Lastly, a machine learning-based human activity recognition method was incorporated to make the CoP detection process more automatic. Through a thorough validation test with the clinical level lab equipment, our system can generate the CoP measurements with high accuracy.
引用
收藏
页码:27037 / 27044
页数:8
相关论文
共 50 条
  • [31] Transcatheter aortic valve implantation in nonagenarians: long- term cohort analysis from a pioneered center
    Durand, E.
    Avinee, G.
    Tron, C.
    Bettinger, N.
    Bouhzam, N.
    Dacher, J. N.
    Bauer, F.
    Liztler, P. Y.
    Cribier, A.
    Eltchaninoff, H.
    EUROPEAN HEART JOURNAL, 2017, 38 : 156 - 156
  • [32] Cisplatin-induced Hearing Loss: The Need for a Long- term Evaluating System
    Yasui, Naoko
    Adachi, Nodoka
    Kato, Motohiro
    Koh, Katsuyoshi
    Asanuma, Satoshi
    Sakata, Hideaki
    Hanada, Ryoji
    JOURNAL OF PEDIATRIC HEMATOLOGY ONCOLOGY, 2014, 36 (04) : E241 - E245
  • [33] Long-term power performance evaluation of vertical building integrated photovoltaic system
    Kim, Jaewon
    Lee, Hyomun
    Choi, Minjoo
    Kim, Dongsu
    Yoon, Jongho
    RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2024, 206
  • [34] Integrated 3D motion and plantar pressure measurement for in-shoe orthoses evaluation
    Woodburn, J.
    Helliwell, P.
    Clinical Biomechanics, 1999, 14 (08):
  • [35] EVALUATION OF LONG- VERSUS SHORT-TERM USE OF PATIROMER ON HEALTHCARE RESOURCE UTILIZATION IN THE PATIROMER LONG-TERM USE EVALUATION (VALUE) STUDY
    Gupta, A.
    Kammerer, J.
    Shaik, I
    Mukherjee, K. G.
    Oliveira, J.
    Thakar, C.
    VALUE IN HEALTH, 2022, 25 (12) : S70 - S70
  • [36] Long-, medium- and short-term dynamics of soil acidity in an integrated crop–livestock system under different grazing intensities
    Amanda P. Martins
    Diego Cecagno
    José Bernardo M. Borin
    Fernando Arnuti
    Sarah H. Lochmann
    Ibanor Anghinoni
    Carlos A. Bissani
    Cimélio Bayer
    Paulo César F. Carvalho
    Nutrient Cycling in Agroecosystems, 2016, 104 : 67 - 77
  • [37] Experimental evaluation of long- and short-term moisture damage characteristics of asphalt mixtures
    Varveri, Aikaterini
    Avgerinopoulos, Stavros
    Scarpas, Athanasios
    ROAD MATERIALS AND PAVEMENT DESIGN, 2016, 17 (01) : 168 - 186
  • [38] LONG- AND SHORT-TERM BLOOD PRESSURE VARIABILITIES IN PATIENTS WITH CONTROLLED ARTERIAL HYPERTENSION ARE NOT INTERCHANGEABLE
    Troitskaya, E.
    Kotovskaya, N.
    Kotovskaya, Y.
    Kobalava, Z.
    JOURNAL OF HYPERTENSION, 2016, 34 : E296 - E297
  • [39] Wireless In- Mold Melt Front Detection for Injection Molding: A Long- Term Evaluation
    Mueller, Florian
    Kukla, Christian
    Lucyshyn, Thomas
    Harker, Matthew
    Rath, Gerhard
    Holzer, Clemens
    JOURNAL OF APPLIED POLYMER SCIENCE, 2014, 131 (11)
  • [40] Long- and Short-Term Effects of Seismic Waves and Coseismic Pressure Changes on Fractured Aquifers
    Zhang, Yan
    Manga, Michael
    Fu, Li-Yun
    Zhang, Huai
    Huang, Tianming
    Yang, Qiuye
    Cui, Zhen-Dong
    Qi, Shengwen
    Huang, Yuan
    JOURNAL OF GEOPHYSICAL RESEARCH-SOLID EARTH, 2024, 129 (03)