A Shoe-Integrated Sensor System for Long- Term Center of Pressure Evaluation

被引:13
|
作者
Guo, Rui [1 ]
Cheng, Xiang [2 ]
Hou, Zong-Chen [3 ,4 ]
Ma, Jing-Zhong [1 ]
Zheng, Wen-Qiang [5 ]
Wu, Xiao-Ming [1 ]
Jiang, Dong [3 ,4 ]
Pan, Yu [2 ]
Ren, Tian-Ling [1 ]
机构
[1] Tsinghua Univ, Beijing Natl Res Ctr Informat Sci & Technol BNRis, Sch Integrated Circuits, Beijing 100084, Peoples R China
[2] Tsinghua Changgung Hosp, Dept Phys Med & Rehabil, Beijing 102218, Peoples R China
[3] Peking Univ, Hosp 3, Dept Sports Med, Beijing 100191, Peoples R China
[4] Peking Univ, Inst Sports Med, Beijing 100191, Peoples R China
[5] Fuzhou Inst Data Technol, Fuzhou 350200, Peoples R China
基金
北京市自然科学基金;
关键词
Sensors; Foot; Monitoring; Hardware; Force; Diseases; Bluetooth; Activity recognition; center of pressure (CoP); plantar pressure; smart insole; static postural control; QUANTIFICATION;
D O I
10.1109/JSEN.2021.3116249
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In clinical, the center of pressure (CoP) is commonly used for accessing the stability of a person's postural control, which is highly associated with various neurological diseases and movement disorders such as Alzheimer's disease, Parkinson's disease, chronic ankle instability. Such a disease usually has a long development or rehabilitation process which requires long-term CoP monitoring. The current CoP evaluation process does not meet the requirement, as it is often complicated and expensive through either the lab-based equipment or the clinical evaluation procedure. Different wearable sensor-based systems with less cost and restrictions have emerged, but their way of CoP calculation requires deliberate calibration of the positions of their sensors, which are not feasible in daily CoP monitoring. In this study, we developed a long-term CoP monitoring system in a smart-shoe form. First, a thin and flexible smart insole with optimal sensor locations was designed to be compact and energy sufficient for a whole-day usage. Then, a user-friendly app on the smartphone with a cloud-based data managing system was developed for applications in both clinical and home environments. Additionally, a simplified CoP estimation model was created without the need for calibration. Lastly, a machine learning-based human activity recognition method was incorporated to make the CoP detection process more automatic. Through a thorough validation test with the clinical level lab equipment, our system can generate the CoP measurements with high accuracy.
引用
收藏
页码:27037 / 27044
页数:8
相关论文
共 50 条
  • [21] LONG- TERM EFFICACY OF THE TOPAS™ SYSTEM FOR TREATMENT OF FECAL INCONTINENCE
    Fenner, D.
    Zutshi, M.
    Lucente, V
    Culligan, P.
    Nihira, M.
    Mellgren, A.
    NEUROUROLOGY AND URODYNAMICS, 2015, 34 : S127 - S128
  • [22] Mandibular Distraction in Hemifacial Microsomia Is Not a Permanent Treatment: A Long- term Evaluation
    Kurogi Ascenco, Adriana Sayuri
    Balbinot, Priscilla
    Maluf Junior, Ivan
    D'Oro, Ubiratan
    Busato, Luciano
    Freitas, Renato da Silva
    JOURNAL OF CRANIOFACIAL SURGERY, 2014, 25 (02) : 352 - 354
  • [23] An Advanced Gait Monitoring System Based on Air Pressure Sensor Embedded in a Shoe
    Abinaya, B.
    Latha, V
    Suchetha, M.
    INTERNATIONAL CONFERENCE ON MODELLING OPTIMIZATION AND COMPUTING, 2012, 38 : 1634 - 1643
  • [24] An Integrated Electricity-Gas-Heat Energy System Based on the Synergy of Long- and Short-Term Energy Storage
    Zhang, Min
    Wang, Jinhao
    Zhi, Huiqiang
    Zhao, Jun
    Chang, Xiao
    Zhang, Shifeng
    Guo, Xiangyu
    Wang, Tengxin
    ENERGIES, 2025, 18 (01)
  • [25] LONG- TERM EFFICACY OF THE TOPAS T SYSTEM FOR TREATMENT OF FECAL INCONTINENCE
    Fenner, D.
    Zutshi, M.
    Lucente, V.
    Culligan, P.
    Mellgren, A.
    DISEASES OF THE COLON & RECTUM, 2015, 58 (05) : E275 - E276
  • [26] Long-Term Motion and Pace Detection System with Wearable Shoe Module
    Cho, Wei-Ting
    Huang, Yueh-Min
    JOURNAL OF INTERNET TECHNOLOGY, 2015, 16 (04): : 581 - 591
  • [27] A blood pressure sensor for long-term implantation
    Bullister, E
    Reich, S
    d'Entremont, P
    Silverman, N
    Sluetz, J
    ARTIFICIAL ORGANS, 2001, 25 (05) : 376 - 379
  • [28] Investigation of long term drift of an intraocular pressure sensor
    Alex Phan
    Phuong Truong
    Christoph Schade
    Aditya Vasan
    James Friend
    Frank E. Talke
    Microsystem Technologies, 2021, 27 : 2473 - 2479
  • [29] Investigation of long term drift of an intraocular pressure sensor
    Phan, Alex
    Truong, Phuong
    Schade, Christoph
    Vasan, Aditya
    Friend, James
    Talke, Frank E.
    MICROSYSTEM TECHNOLOGIES-MICRO-AND NANOSYSTEMS-INFORMATION STORAGE AND PROCESSING SYSTEMS, 2021, 27 (06): : 2473 - 2479
  • [30] Optimizing Pressure Sensor Array Data for a Smart-Shoe Fall Monitoring System
    Light, Janet
    Cha, Sangwhan
    Chowdhury, Maksudul
    2015 IEEE SENSORS, 2015, : 410 - 413