Interfacial Bond Behavior of High Strength Concrete Filled Steel Tube after Exposure to Elevated Temperatures and Cooled by Fire Hydrant

被引:8
|
作者
Chen, Zongping [1 ,2 ]
Tang, Jiyu [1 ]
Zhou, Xingyu [1 ]
Zhou, Ji [1 ]
Chen, Jianjia [1 ]
机构
[1] Guangxi Univ, Coll Civil Engn & Architecture, Nanning 530004, Peoples R China
[2] Guangxi Univ, Key Lab Disaster Prevent & Struct Safety, Chinese Minist Educ, Nanning 530004, Peoples R China
基金
中国国家自然科学基金;
关键词
elevated temperatures and water-cooling exposure; high-strength concrete; circular steel tube; bond strength; slip behavior;
D O I
10.3390/ma13010150
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
For the engineering structure in case of fire, a fire hydrant is generally used for extinguishing the fire. This paper presents an experimental investigation on interfacial bond behavior of high-strength concrete-filled steel tube (HSCFST) after exposure to elevated temperatures and cooled by fire hydrant using the pull-out test of 22 specimens. According to the experimental study, the failure mechanism of HSCFST exposed to elevated temperatures and water-cooling (ETWC) was revealed, the influence of various parameters on the bond behavior was analyzed, and the calculation formula of the bond strength of HSCFST subjected to ETWC was put forward. The results show that the load-slip curves of the loading end and the free end of the specimen are basically similar, and can be divided into three types of typical curves. In the push out test, the strain on the outer surface of the steel tube is exponentially distributed with its distance from the loading end. After ETWC exposure, the bond strength of the specimen is less affected by the concrete strength, which is inversely proportional to the anchorage length, and it is basically stable after the constant temperature duration is longer than 60 min. With the increase of the maximum temperature, the ultimate bond strength increases first, then decreases and then increases, and the residual bond strength increases first and then decreases. Besides, the study indicate that cooling method has significant influence on the bond behavior, compared with natural cooling specimens, the ultimate bond strength, residual bond strength, and shear bond stiffness of water-cooling specimens are smaller, and the interfacial energy dissipation capacity is larger.
引用
收藏
页数:23
相关论文
共 50 条
  • [41] Experimental Study of Behavior of Ceramsite Concrete Filled Steel Tubes after Exposure to Fire
    Zhou, Ming
    wang, Xintang
    Wang, Jianmin
    Xie, Zhiguo
    FRONTIERS OF GREEN BUILDING, MATERIALS AND CIVIL ENGINEERING, PTS 1-8, 2011, 71-78 : 3721 - 3724
  • [42] Behavior of CFRP retrofitted concrete filled steel tubular beams after exposure to fire
    Tao, Zhong
    Han, Lin-Hai
    Wang, Ling-Ling
    Advances in Structural Engineering:Theory and Applications Vols 1 and 2, 2006, : 954 - 959
  • [43] Residual mechanical properties and numerical analysis of recycled pebble aggregate concrete after high temperature exposure and cooled by fire hydrant
    Chen, Zongping
    Xu, Ruitian
    Liang, Houran
    CONSTRUCTION AND BUILDING MATERIALS, 2022, 319
  • [44] Experimental behavior of axially loaded circular high-strength concrete-filled high-strength steel tubular stub columns after exposure to fire
    Li, Ying
    Liu, Faqi
    Du, Tao
    Pan, Yanchong
    Yang, Hua
    Li, Yinglong
    THIN-WALLED STRUCTURES, 2024, 203
  • [45] The hysteretic behavior of high strength concrete filled steel tube under compression and bending
    Wang, Z
    Zhen, YH
    COMPOSITE AND HYBRID STRUCTURES, VOLS 1 AND 2, 2000, : 599 - 604
  • [46] Shear behavior of high-strength square concrete filled steel tube members
    Lai, Zhichao
    Han, Wenbing
    Wang, Ying
    Yang, Xiaoqiang
    Huang, Wenjin
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2022, 196
  • [47] Analysis on the impact behavior of super high strength concrete filled steel tube columns
    College of Civil Engineering, Putian University, Putian, Fujian, China
    不详
    Metall. Min. Ind., 12 (6-11):
  • [48] FLEXURAL BEHAVIOR OF REINFORCED HOLLOW HIGH STRENGTH CONCRETE FILLED SQUARE STEEL TUBE
    Yang, Zhi-Jian
    Zhang, Shu
    Cui, Wei-Zhe
    Li, Guo-Chang
    ADVANCED STEEL CONSTRUCTION, 2024, 20 (02): : 199 - 207
  • [50] Behaviour and residual compression resistances of circular high strength concrete-filled stainless steel tube (HCFSST) stub columns after exposure to fire
    He, An
    Liang, Yating
    Zhao, Ou
    ENGINEERING STRUCTURES, 2020, 203