Cellular responses to flow diverters in a tissue-engineered aneurysm model

被引:6
|
作者
Liu, Wenjing [1 ,2 ]
Dai, Daying [1 ]
Ding, Yong-Hong [1 ]
Liu, Yang [1 ]
Temnyk, Kristen [3 ]
Shen, Tiffany W. [3 ]
Cardinal, Kristen O'Halloran [3 ]
Kallmes, David F. [1 ]
Kadirvel, Ramanathan [1 ]
机构
[1] Mayo Clin, Radiol, Rochester, MN 55905 USA
[2] China Med Univ, Geriatr, Hosp 1, Shenyang, Peoples R China
[3] Cal Poly, Biomed Engn Dept, San Luis Obispo, CA USA
基金
美国国家卫生研究院;
关键词
aneurysm; flow diverter; device; EMBOLIZATION; CELLS;
D O I
10.1136/neurintsurg-2020-016593
中图分类号
R445 [影像诊断学];
学科分类号
100207 ;
摘要
Background Notwithstanding the widespread implementation of flow diverters (FDs) in the treatment of intracranial aneurysms, the exact mechanism of action of these devices remains elusive. We aimed to advance the understanding of cellular responses to FD implantation using a 3D tissue-engineered in vitro aneurysm model. Methods Aneurysm-like blood vessel mimics (aBVMs) were constructed by electrospinning polycaprolactone nanofibers onto desired aneurysm-like geometries. aBVMs were seeded with human aortic smooth muscle cells (SMCs) followed by human aortic endothelial cells (ECs). FDs were then deployed in the parent vessel of aBVMs covering the aneurysm neck and were cultivated for 7, 14, or 28 days (n=3 for each time point). The EC and SMC coverage in the neck was measured semi-quantitatively. Results At day 7, the device segment in contact with the parent vessel was partially endothelialized. Also, the majority of device struts, but not pores, at the parent vessel and neck interface were partially covered with ECs and SMCs, while device struts in the middle of the neck lacked cell coverage. At 14 days, histology verified a neointimal-like lining had formed, partially covering both the struts and pores in the center of the neck. At 28 days, the majority of the neck was covered with a translucent neointimal-like layer. A higher degree of cellular coverage was seen on the struts and pores at the neck at 28 days compared with both 7 and 14 days. Conclusion aBVMs can be a valuable alternative tool for evaluating the healing mechanisms of endovascular aneurysm devices.
引用
收藏
页码:746 / 751
页数:6
相关论文
共 50 条
  • [31] A practical model for economic evaluation of tissue-engineered therapies
    Tan, Tien-En
    Peh, Gary S. L.
    Finkelstein, Eric A.
    Mehta, Jodhbir S.
    WILEY INTERDISCIPLINARY REVIEWS-SYSTEMS BIOLOGY AND MEDICINE, 2015, 7 (02) : 91 - 100
  • [32] Experimental study on tissue-engineered vascular model in vitro
    Xia, WS
    Lu, KH
    Ai, YF
    Xiong, M
    Zhang, LX
    Shu, MG
    TISSUE ENGINEERING, 2006, 12 (04): : 1088 - 1088
  • [33] Generation and Grafting of Tissue-engineered Vessels in a Mouse Model
    Wong, Mei M.
    Hong, Xuechong
    Karamariti, Eirini
    Hu, Yanhua
    Xu, Qingbo
    JOVE-JOURNAL OF VISUALIZED EXPERIMENTS, 2015, (97):
  • [34] Addendum: A tissue-engineered scale model of the heart ventricle
    Luke A. MacQueen
    Sean P. Sheehy
    Christophe O. Chantre
    John F. Zimmerman
    Francesco S. Pasqualini
    Xujie Liu
    Josue A. Goss
    Patrick H. Campbell
    Grant M. Gonzalez
    Sung-Jin Park
    Andrew K. Capulli
    John P. Ferrier
    T. Fettah Kosar
    L. Mahadevan
    William T. Pu
    Kevin Kit Parker
    Nature Biomedical Engineering, 2022, 6 : 1318 - 1318
  • [35] A Tissue-Engineered Model of A Tendon-to-Bone Enthesis
    Miss, Qing Yu
    Jacquet, Robin
    Elias, John
    Landis, William
    FASEB JOURNAL, 2015, 29
  • [36] Tissue-Engineered Cellular Neotendinous Constructs for Chronic Hernia Repair in a Rat
    Mahalingam, Vasu
    VanDusen, Keith
    Myers, Angela
    Trzcinski, Brett
    Arruda, Ellen
    Larkin, Lisa
    Kuzon, William
    FASEB JOURNAL, 2014, 28 (01):
  • [37] Effect of pulsatile flow on the development of a tissue-engineered vascular graft
    Baguneid, MS
    Seifalian, A
    Hamilton, G
    Walker, MG
    BRITISH JOURNAL OF SURGERY, 2001, 88 : 76 - 76
  • [38] Tissue-Engineered Bioreactors with Flow Channels Molded by Polypod Particles
    Suirakigawa, Nana
    Hara, Yuta
    Sakamoto, Hiroki
    Ijima, Hiroyuki
    ADVANCED BIOMEDICAL ENGINEERING, 2016, 5 : 105 - 110
  • [39] In Reply: The Era of Flow Diverters in Aneurysm Treatment
    Arrese, Ignacio
    Sarabia, Rosario
    NEUROSURGERY, 2014, 74 (03) : E342 - E343
  • [40] INFLUENCE OF DYNAMIC FLOW IN MATRIX COMPOSITION AND UROTHELIUM DIFFERENTIATION OF A TISSUE-ENGINEERED MODEL OF URETERAL SUBSTITUTE
    Cloutier, Jonathan
    Cattan, Valerie
    Bernard, Genevieve
    Ouellet, Gabrielle
    Bolduc, Stephane
    JOURNAL OF UROLOGY, 2011, 185 (04): : E38 - E39