Load-bearing capacity of steel profiles with tubular sections restrained in reinforced concrete

被引:1
|
作者
Kindmann, Rolf [1 ]
Vette, Jan [2 ]
机构
[1] Ingenieursozietat SKP Schurmann Kindmann & Partne, Dortmund Prinz Friedrich Karl Str 36, D-44135 Dortmund, Germany
[2] FH Munster, Fachbereich Bauingn, Corrensstr 25, D-48149 Munster, Germany
关键词
steel profiles with tubular sections; connections to reinforced concrete; restraint; restrained columns;
D O I
10.1002/stab.202000032
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
If steel profiles with tubular sections are used as columns or beams, they can be restrained into foundations or walls made of reinforced concrete. These connections generally act like restraints that require a sufficient length. In the following, profiles with tubular sections restrained in reinforced concrete constructions are investigated and load-bearing capacity verifications are treated in consideration of the restraining length and concrete compressive stresses in the restraint area, as well as verifications at the relevant points of the profiles. As a supplement to the calculation formulas, diagrams are provided that allow the determination of the restraint length. In many practical applications, the double profile diameter is sufficient as restraint length.
引用
收藏
页码:2 / +
页数:11
相关论文
共 50 条
  • [31] Blast Assessment of Load-Bearing Reinforced Concrete Shear Walls
    Naito, C. J.
    Wheaton, K. P.
    PRACTICE PERIODICAL ON STRUCTURAL DESIGN AND CONSTRUCTION, 2006, 11 (02) : 112 - 121
  • [32] Modeling of degradation processes in concrete: Probabilistic lifetime and load-bearing capacity assessment of existing reinforced concrete bridges
    Somodikova, Martina
    Lehky, David
    Dolezel, Jiri
    Novak, Drahomir
    ENGINEERING STRUCTURES, 2016, 119 : 49 - 60
  • [33] Experimental investigation on axial load-bearing property of steel column encased by reinforced concrete cover
    Department of Civil Engineering, Tsinghua University, Beijing
    100084, China
    不详
    100084, China
    不详
    300072, China
    不详
    110168, China
    不详
    110044, China
    Jianzhu Jiegou Xuebao, (16-21):
  • [34] Textile reinforced concrete load-bearing behaviour, design and application
    Hegger, Josef
    Horstmann, Michael
    Voss, Stefan
    Will, Norbert
    BETON- UND STAHLBETONBAU, 2007, 102 (06) : 362 - 370
  • [35] Tests of load-bearing slender reinforced concrete walls in fire
    Crozier, Damian A.
    Sanjayan, Jay G.
    2000, American Concrete Institute (97)
  • [36] Artificial Neural Network Models for Determining the Load-Bearing Capacity of Eccentrically Compressed Short Concrete-Filled Steel Tubular Columns
    Chepurnenko, Anton
    Turina, Vasilina
    Akopyan, Vladimir
    CIVILENG, 2024, 5 (01): : 150 - 168
  • [37] Load-bearing capacity of fiber reinforced fixed composite bridges
    Basaran, Emine Goncu
    Ayna, Emrah
    Li, Sadullah Uctas
    Vallittu, Pekka K.
    Lassila, Lippo V. J.
    ACTA ODONTOLOGICA SCANDINAVICA, 2013, 71 (01) : 65 - 71
  • [38] Load-Bearing Capacity of Slender Columns of Nonreinforced Concrete.
    Kupfer, H.B.
    Kupfer, H.
    Stegbauer, A.
    Bauingenieur Berlin, 1984, 59 (05): : 173 - 180
  • [39] Load-bearing capacity of precast concrete segmental tunnel linings
    Comportamiento resistente de revestimientos de túnel de anillos de dovelas prefabricadas de hormigón
    1600, Colegio de Ingenieros de Caminos Canales y Puertos (160):
  • [40] Non-linear simulation of load-bearing capacity for steel-encased concrete piles
    Gorynin, G. L.
    Snigireva, V. A.
    PROCEEDINGS OF THE INTERNATIONAL CONFERENCE ACTUAL ISSUES OF MECHANICAL ENGINEERING 2017 (AIME 2017), 2017, 133 : 816 - 822