Effect of Anisotropic Electrical Conductivity Induced by Fiber Orientation on Ablation Characteristics of Pulsed Field Ablation in Atrial Fibrillation Treatment: A Computational Study

被引:8
|
作者
Zang, Lianru [1 ]
Gu, Kaihao [1 ]
Ji, Xingkai [1 ]
Zhang, Hao [1 ]
Yan, Shengjie [1 ]
Wu, Xiaomei [1 ,2 ,3 ,4 ,5 ]
机构
[1] Fudan Univ, Ctr Biomed Engn, Sch Informat Sci & Technol, Shanghai 200438, Peoples R China
[2] Fudan Univ, Acad Engn & Technol, Shanghai 200433, Peoples R China
[3] Fudan Univ, Key Lab Med Imaging Comp & Comp Assisted Interven, Shanghai 200032, Peoples R China
[4] Shanghai Engn Res Ctr Assist Devices, Shanghai 200093, Peoples R China
[5] Fudan Univ, Yiwu Res Inst, Yiwu 322000, Peoples R China
关键词
pulsed field ablation; atrial fibrillation; fiber orientation; anisotropic electrical conductivity; finite element analysis; RADIOFREQUENCY CARDIAC ABLATION; TISSUE; FLOW; CATHETER; LESIONS;
D O I
10.3390/jcdd9100319
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Pulsed field ablation (PFA) is a promising new ablation modality for the treatment of atrial fibrillation (AF); however, the effect of fiber orientation on the ablation characteristics of PFA in AF treatment is still unclear, which is likely an essential factor in influencing the ablation characteristics. This study constructed an anatomy-based left atrium (LA) model incorporating fiber orientation and selected various electrical conductivity and ablation targets to investigate the effect of anisotropic electrical conductivity (AC), compared with isotropic electrical conductivity (IC), on the ablation characteristics of PFA in AF treatment. The results show that the percentage differences in the size of the surface ablation area between AC and IC are greater than 73.71%; the maximum difference in the size of the ablation isosurface between AC and IC at different locations in the atrial wall is 3.65 mm (X-axis), 3.65 mm (Z-axis), and 4.03 mm (X-axis), respectively; and the percentage differences in the size of the ablation volume are greater than 6.9%. Under the condition of the pulse, the amplitude is 1000 V, the total PFA duration is 1 s, and the pulse train interval is 198.4 ms; the differences in the temperature increase between AC and IC in LA are less than 2.46 degrees C. Hence, this study suggests that in further exploration of the computational study of PFA in AF treatment using the same or similar conditions as those used here (myocardial electrical conductivity, pulse parameters, and electric field intensity damage threshold), to obtain more accurate computational results, it is necessary to adopt AC rather than IC to investigate the size of the surface ablation area, the size of the ablation isosurface, or the size of the ablation volume generated by PFA in LA. Moreover, if only investigating the temperature increase generated by PFA in LA, adopting IC instead of AC for simplifying the model construction process is reasonable.
引用
收藏
页数:22
相关论文
共 50 条
  • [21] Pulsed Field Ablation for the Treatment of Atrial Fibrillation: A Review and a Look into its Future
    Guttipatti, Pavithran
    Saadallah, Najla
    Wan, Elaine Y.
    Parameters, P. F. A. Waveform
    HEART SURGERY FORUM, 2024, 27 (02): : E169 - E179
  • [22] Feasibility of Deep Sedation for Catheter Ablation of Atrial Fibrillation Using Pulsed Field Ablation
    Patel, Romil
    Sam, Riya
    Singh, Lavisha
    Fisher, Westby
    Metzl, Mark
    Nazari, Jose
    Ro, Alex
    Demo, Hany
    Wasserlauf, Jeremiah
    CIRCULATION, 2024, 150
  • [23] Pulsed field ablation in atrial fibrillation ablation: where are we and where are we going?
    Schiavone, Marco
    Tondo, Claudio
    EUROPEAN HEART JOURNAL SUPPLEMENTS, 2025, 27 : i167 - i170
  • [24] Study on Optimal Parameter and Target for Pulsed-Field Ablation of Atrial Fibrillation
    Ye, Xuying
    Liu, Shangzhong
    Yin, Huijuan
    He, Qiang
    Xue, Zhixiao
    Lu, Chengzhi
    Su, Siying
    FRONTIERS IN CARDIOVASCULAR MEDICINE, 2021, 8
  • [25] Hope, Hype, and Reality of Pulsed Field Ablation for Atrial Fibrillation
    Bunch, T. Jared
    NEW ENGLAND JOURNAL OF MEDICINE, 2023, 389 (18): : 1720 - 1721
  • [26] Pulsed Field Ablation for Atrial Fibrillation: Mechanisms, Advantages, and Limitations
    Jiang, Shali
    Qian, Frank
    Ji, Shuting
    Li, Luohong
    Liu, Qiming
    Zhou, Shenghua
    Xiao, Yichao
    REVIEWS IN CARDIOVASCULAR MEDICINE, 2024, 25 (04)
  • [27] Considerations regarding safety with pulsed field ablation for atrial fibrillation
    Sugrue, Alan
    Shabtaie, Samuel
    Tan, Nicholas Y.
    Maor, Elad
    Kapa, Suraj
    Asirvatham, Samuel J.
    HEART RHYTHM O2, 2024, 5 (09): : 655 - 661
  • [28] Pulsed-Field Ablation for Atrial Fibrillation The Future Is Now?
    Mathuria, Nilesh
    JACC-CLINICAL ELECTROPHYSIOLOGY, 2021, 7 (05) : 628 - 629
  • [29] Pulsed field ablation for atrial fibrillation: is it truly as good as it sounds?
    Yoo, David H.
    Heist, E. Kevin
    JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2024, 67 (02) : 237 - 238
  • [30] Pulsed Field Ablation to Treat Atrial Fibrillation: A Review of the Literature
    Di Monaco, Antonio
    Vitulano, Nicola
    Troisi, Federica
    Quadrini, Federico
    Romanazzi, Imma
    Calvi, Valeria
    Grimaldi, Massimo
    JOURNAL OF CARDIOVASCULAR DEVELOPMENT AND DISEASE, 2022, 9 (04)