A Diagnostic Accuracy Meta-analysis of Endoanal Ultrasound and MRI for Perianal Fistula Assessment

被引:137
|
作者
Siddiqui, Muhammed R. S. [1 ,2 ]
Ashrafian, Hutan [2 ]
Tozer, Phil [1 ]
Daulatzai, Najib [1 ]
Burling, David [1 ]
Hart, Ailsa [1 ,2 ]
Athanasiou, Thanos [2 ]
Phillips, Robin K. [1 ,2 ]
机构
[1] St Marks Inst, Harrow HA1 3UJ, Middx, England
[2] Univ London Imperial Coll Sci Technol & Med, Dept Surg & Canc, London, England
关键词
Ultrasound; Endoanal; Magnetic resonance imaging; Perianal fistula; IN-ANO; CROHNS-DISEASE; ANAL ENDOSONOGRAPHY; ENDOSCOPIC ULTRASOUND; ANORECTAL FISTULA; SURGICAL FINDINGS; ULTRASONOGRAPHY; ABSCESS; FISTULOGRAPHY; SEPSIS;
D O I
10.1097/DCR.0b013e318249d26c
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
BACKGROUND: Imaging modalities such as endoanal ultrasound or MRI can be useful preoperative adjuncts before the appropriate surgical intervention for perianal fistulas. OBJECTIVES: We present a systematic review of published literature comparing endoanal ultrasound with MRI for the assessment of idiopathic and Crohn's perianal fistulas. DESIGN: A meta-analysis was performed to obtain pooled values for specificity and sensitivity. SETTINGS: Electronic databases were searched from January 1970 to October 2010 for published studies. PATIENTS AND INTERVENTIONS: Four studies were used in our analysis. There were 241 fistulas in the ultrasound group and 240 in the magnetic resonance group. RESULTS: The combined sensitivity and specificity of magnetic resonance for fistula detection were 0.87 (95% CI: 0.63-0.96) and 0.69 (95% CI: 0.51-0.82). There was a high degree of heterogeneity between studies reporting on MRI sensitivity (df = 3, I-2 = 93%). This compares to a sensitivity and specificity for endoanal ultrasound of 0.87 (95% CI: 0.70-0.95) and 0.43 (95% CI: 0.21-0.69). There was a high degree of heterogeneity between studies reporting on endoanal ultrasound sensitivity (df = 3, I-2 = 92%). CONCLUSIONS: From the available literature, the summarized performance characteristics for MRI and endoanal ultrasound demonstrate comparable sensitivities at detecting perianal fistulas, although the specificity for MRI was higher than that for endoanal ultrasound. Both specificity values are considered to be diagnostically poor, however. The high degree of data heterogeneity and the shortage of applicable studies precludes any firm conclusions being made for clinical practice. Future trials with improved study design (including prospective data collection and consideration of verification bias) may help to further clarify the role of MRI in the assessment and treatment response monitoring of perianal fistulas (particularly in patients with Crohn's disease).
引用
收藏
页码:576 / 585
页数:10
相关论文
共 50 条
  • [31] Diagnostic Accuracy of MRI for Solid Renal Masses: A Systematic Review and Meta-analysis
    Frank, Robert A.
    Dawit, Haben
    Bossuyt, Patrick M. M.
    Leeflang, Mariska
    Flood, Trevor A.
    Breau, Rodney H.
    McInnes, Matthew D. F.
    Schieda, Nicola
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2023, 57 (04) : 1172 - 1184
  • [32] The Diagnostic Accuracy of Different MRI Sequences for Different Meniscus Lesions: A Meta-analysis
    Jhonatan, Felix Young
    Li, Kun
    Chen, Jinhua
    Zhou, Liyu
    Yang, Huilin
    Huang, Lixin
    Du, Jun
    CURRENT MEDICAL IMAGING, 2023, 19 (11) : 1245 - 1257
  • [33] Ultrasound for the diagnosis of testicular torsion: a systematic review and meta-analysis of diagnostic accuracy
    Alexander, C. E.
    Light, A.
    Chan, V
    Asif, A.
    Clement, K.
    Warren, H.
    Zimmermann, E.
    Khadouri, S.
    Eyskens, P.
    Takwoingi, Y.
    Sidhu, P.
    Shah, T.
    Kasivisvanathan, V
    EUROPEAN UROLOGY, 2024, 85 : S41 - S41
  • [34] Diagnostic accuracy of ultrasound superb microvascular imaging for breast tumor: a meta-analysis
    Zhong, Lin
    Wang, Cong
    MEDICAL ULTRASONOGRAPHY, 2020, 22 (03) : 313 - 318
  • [35] Diagnostic accuracy of lung ultrasound for pulmonary embolism: a systematic review and meta-analysis
    Squizzato, A.
    Rancan, E.
    Dentali, F.
    Bonzini, M.
    Guasti, L.
    Steidl, L.
    Mathis, G.
    Ageno, W.
    JOURNAL OF THROMBOSIS AND HAEMOSTASIS, 2013, 11 (07) : 1269 - 1278
  • [36] Diagnostic accuracy of cardiopulmonary ultrasound for pulmonary embolism: A systematic review and meta-analysis
    Cao, Jingli
    Sun, Junjie
    Wang, Yuanyuan
    Wang, Lihong
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2022, 39 (02): : 185 - 193
  • [37] Diagnostic accuracy of lung ultrasound for pulmonary embolism: a systematic review and meta-analysis
    Squizzato, A.
    Rancan, E.
    Dentali, F.
    Bonzini, M.
    Guasti, L.
    Steidl, L.
    Mathis, G.
    Ageno, W.
    JOURNAL OF THROMBOSIS AND HAEMOSTASIS, 2013, 11 : 601 - 601
  • [38] Diagnostic accuracy of ultrasound for small bowel obstruction: A systematic review and meta-analysis
    Lin, You-Cheng
    Yu, Yi-Chung
    Huang, Yu-Ting
    Wu, Yun-Yu
    Wang, Ting-Cheng
    Huang, Wen-Cheng
    Yang, Meng-Duo
    Hsu, Yuan-Pin
    EUROPEAN JOURNAL OF RADIOLOGY, 2021, 136
  • [39] Diagnostic test accuracy of ultrasound for sarcopenia diagnosis: A systematic review and meta-analysis
    Fu, Hongbo
    Wang, Lei
    Zhang, Wenyi
    Lu, Jing
    Yang, Ming
    JOURNAL OF CACHEXIA SARCOPENIA AND MUSCLE, 2023, 14 : 57 - 70
  • [40] Abdominal Ultrasound and Its Diagnostic Accuracy in Diagnosing Acute Appendicitis: A Meta-Analysis
    Fu, Jian
    Zhou, Xu
    Chen, Liang
    Lu, Sheng
    FRONTIERS IN SURGERY, 2021, 8