A Diagnostic Accuracy Meta-analysis of Endoanal Ultrasound and MRI for Perianal Fistula Assessment

被引:137
|
作者
Siddiqui, Muhammed R. S. [1 ,2 ]
Ashrafian, Hutan [2 ]
Tozer, Phil [1 ]
Daulatzai, Najib [1 ]
Burling, David [1 ]
Hart, Ailsa [1 ,2 ]
Athanasiou, Thanos [2 ]
Phillips, Robin K. [1 ,2 ]
机构
[1] St Marks Inst, Harrow HA1 3UJ, Middx, England
[2] Univ London Imperial Coll Sci Technol & Med, Dept Surg & Canc, London, England
关键词
Ultrasound; Endoanal; Magnetic resonance imaging; Perianal fistula; IN-ANO; CROHNS-DISEASE; ANAL ENDOSONOGRAPHY; ENDOSCOPIC ULTRASOUND; ANORECTAL FISTULA; SURGICAL FINDINGS; ULTRASONOGRAPHY; ABSCESS; FISTULOGRAPHY; SEPSIS;
D O I
10.1097/DCR.0b013e318249d26c
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
BACKGROUND: Imaging modalities such as endoanal ultrasound or MRI can be useful preoperative adjuncts before the appropriate surgical intervention for perianal fistulas. OBJECTIVES: We present a systematic review of published literature comparing endoanal ultrasound with MRI for the assessment of idiopathic and Crohn's perianal fistulas. DESIGN: A meta-analysis was performed to obtain pooled values for specificity and sensitivity. SETTINGS: Electronic databases were searched from January 1970 to October 2010 for published studies. PATIENTS AND INTERVENTIONS: Four studies were used in our analysis. There were 241 fistulas in the ultrasound group and 240 in the magnetic resonance group. RESULTS: The combined sensitivity and specificity of magnetic resonance for fistula detection were 0.87 (95% CI: 0.63-0.96) and 0.69 (95% CI: 0.51-0.82). There was a high degree of heterogeneity between studies reporting on MRI sensitivity (df = 3, I-2 = 93%). This compares to a sensitivity and specificity for endoanal ultrasound of 0.87 (95% CI: 0.70-0.95) and 0.43 (95% CI: 0.21-0.69). There was a high degree of heterogeneity between studies reporting on endoanal ultrasound sensitivity (df = 3, I-2 = 92%). CONCLUSIONS: From the available literature, the summarized performance characteristics for MRI and endoanal ultrasound demonstrate comparable sensitivities at detecting perianal fistulas, although the specificity for MRI was higher than that for endoanal ultrasound. Both specificity values are considered to be diagnostically poor, however. The high degree of data heterogeneity and the shortage of applicable studies precludes any firm conclusions being made for clinical practice. Future trials with improved study design (including prospective data collection and consideration of verification bias) may help to further clarify the role of MRI in the assessment and treatment response monitoring of perianal fistulas (particularly in patients with Crohn's disease).
引用
收藏
页码:576 / 585
页数:10
相关论文
共 50 条
  • [21] Diagnostic accuracy of Doppler ultrasound, CT and MRI in Budd Chiari syndrome: systematic review and meta-analysis
    Gupta, Pankaj
    Bansal, Varun
    Kumar-M, Praveen
    Sinha, Saroj K.
    Samanta, Jayanta
    Mandavdhare, Harshal
    Sharma, Vishal
    Dutta, Usha
    Kochhar, Rakesh
    BRITISH JOURNAL OF RADIOLOGY, 2020, 93 (1109):
  • [22] Diagnostic Accuracy of Ultrasound for Assessment of Synovial Abnormalities Among Patients With Knee Pain: A Meta-Analysis
    Liu, Ke
    Li, Xiaoxiao
    Weng, Qianlin
    Wang, Yilun
    Wei, Jie
    Zeng, Chao
    Lei, Guanghua
    Jiang, Ting
    ARTHRITIS CARE & RESEARCH, 2024, 76 (02) : 295 - 303
  • [23] Diagnostic accuracy of fetal MRI to detect cleft palate: a meta-analysis
    Hanneke E. M. van der Hoek-Snieders
    Antonius J. M. L. van den Heuvel
    Harmieke van Os-Medendorp
    Digna M. A. Kamalski
    European Journal of Pediatrics, 2020, 179 : 29 - 38
  • [24] Diagnostic accuracy of fetal MRI to detect cleft palate: a meta-analysis
    van der Hoek-Snieders, Hanneke E. M.
    van den Heuvel, Antonius J. M. L.
    van Os-Medendorp, Harmieke
    Kamalski, Digna M. A.
    EUROPEAN JOURNAL OF PEDIATRICS, 2020, 179 (01) : 29 - 38
  • [25] Diagnostic accuracy of ultrasonography for the assessment of maxillofacial fractures: A meta-analysis
    Gadicherla, Srikanth
    Pentapati, Kalyana-Chakravarthy
    Rustaqi, Nasrullah
    Singh, Anupam
    Smriti, Komal
    JOURNAL OF INTERNATIONAL SOCIETY OF PREVENTIVE AND COMMUNITY DENTISTRY, 2021, 11 (05): : 503 - 509
  • [26] Rectal endoscopic ultrasound versus pelvic magnetic resonance for perianal fistula: A meta-analysis and systematic review
    Case, Justin W.
    Mardini, Houssam F.
    Nickl, Nicholas J.
    Grigorian, Alla
    De Villiers, Willem J.
    GASTROINTESTINAL ENDOSCOPY, 2008, 67 (05) : AB198 - AB198
  • [27] A Meta-Analysis of the Diagnostic Accuracy of the SCOFF
    Botella, Juan
    Rosa Sepulveda, Ana
    Huang, Huiling
    Gambara, Hilda
    SPANISH JOURNAL OF PSYCHOLOGY, 2013, 16
  • [28] Meta-analysis methods for diagnostic accuracy
    Begg, Colin B.
    JOURNAL OF CLINICAL EPIDEMIOLOGY, 2008, 61 (11) : 1081 - 1082
  • [29] Meta-analysis for the diagnostic accuracy of a test?
    McDonough, PG
    FERTILITY AND STERILITY, 1999, 71 (02) : 391 - 392
  • [30] The Diagnostic Accuracy of Different MRI Sequences for Different Meniscus Lesions: A Meta-analysis
    Department of Orthopedic Surgery, The First Affiliated Hospital of Soochow University, No. 899 Pinghai Road, Suzhou
    215000, China
    不详
    215127, China
    不详
    215000, China
    Curr. Med. Imaging., 1600, 11 (1245-1257):