A Diagnostic Accuracy Meta-analysis of Endoanal Ultrasound and MRI for Perianal Fistula Assessment

被引:137
|
作者
Siddiqui, Muhammed R. S. [1 ,2 ]
Ashrafian, Hutan [2 ]
Tozer, Phil [1 ]
Daulatzai, Najib [1 ]
Burling, David [1 ]
Hart, Ailsa [1 ,2 ]
Athanasiou, Thanos [2 ]
Phillips, Robin K. [1 ,2 ]
机构
[1] St Marks Inst, Harrow HA1 3UJ, Middx, England
[2] Univ London Imperial Coll Sci Technol & Med, Dept Surg & Canc, London, England
关键词
Ultrasound; Endoanal; Magnetic resonance imaging; Perianal fistula; IN-ANO; CROHNS-DISEASE; ANAL ENDOSONOGRAPHY; ENDOSCOPIC ULTRASOUND; ANORECTAL FISTULA; SURGICAL FINDINGS; ULTRASONOGRAPHY; ABSCESS; FISTULOGRAPHY; SEPSIS;
D O I
10.1097/DCR.0b013e318249d26c
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
BACKGROUND: Imaging modalities such as endoanal ultrasound or MRI can be useful preoperative adjuncts before the appropriate surgical intervention for perianal fistulas. OBJECTIVES: We present a systematic review of published literature comparing endoanal ultrasound with MRI for the assessment of idiopathic and Crohn's perianal fistulas. DESIGN: A meta-analysis was performed to obtain pooled values for specificity and sensitivity. SETTINGS: Electronic databases were searched from January 1970 to October 2010 for published studies. PATIENTS AND INTERVENTIONS: Four studies were used in our analysis. There were 241 fistulas in the ultrasound group and 240 in the magnetic resonance group. RESULTS: The combined sensitivity and specificity of magnetic resonance for fistula detection were 0.87 (95% CI: 0.63-0.96) and 0.69 (95% CI: 0.51-0.82). There was a high degree of heterogeneity between studies reporting on MRI sensitivity (df = 3, I-2 = 93%). This compares to a sensitivity and specificity for endoanal ultrasound of 0.87 (95% CI: 0.70-0.95) and 0.43 (95% CI: 0.21-0.69). There was a high degree of heterogeneity between studies reporting on endoanal ultrasound sensitivity (df = 3, I-2 = 92%). CONCLUSIONS: From the available literature, the summarized performance characteristics for MRI and endoanal ultrasound demonstrate comparable sensitivities at detecting perianal fistulas, although the specificity for MRI was higher than that for endoanal ultrasound. Both specificity values are considered to be diagnostically poor, however. The high degree of data heterogeneity and the shortage of applicable studies precludes any firm conclusions being made for clinical practice. Future trials with improved study design (including prospective data collection and consideration of verification bias) may help to further clarify the role of MRI in the assessment and treatment response monitoring of perianal fistulas (particularly in patients with Crohn's disease).
引用
收藏
页码:576 / 585
页数:10
相关论文
共 50 条
  • [1] A DIAGNOSTIC ACCURACY META-ANALYSIS OF ENDOANAL ULTRASOUND AND MRI FOR PERIANAL FISTULA ASSESSMENT
    Siddiqui, M. R. S.
    Ashrafian, H.
    Tozer, P.
    Daulatzai, N.
    Burling, D.
    Hart, A.
    Athanasiou, T.
    Phillips, R. K.
    GUT, 2012, 61 : A233 - A234
  • [2] A diagnostic accuracy meta-analysis of endoanal ultrasound (EAUS) and magnetic resonance imaging (MRI) for perianal fistula assessment
    Siddiqui, M.
    Ashrafian, H.
    Athanasiou, T.
    Hart, A.
    Phillips, R.
    BRITISH JOURNAL OF SURGERY, 2012, 99 : 145 - 145
  • [3] Role of endoanal ultrasound in the assessment of perianal fistula in correlation with MRI fistulography
    Sayed, Alaa
    El-azizi, Hatem Mohamed Said
    El-barmelgi, Mohamed Yehia Ahmed
    Azzam, Heba
    EGYPTIAN JOURNAL OF RADIOLOGY AND NUCLEAR MEDICINE, 2022, 53 (01):
  • [4] Role of endoanal ultrasound in the assessment of perianal fistula in correlation with MRI fistulography
    Alaa Sayed
    Hatem Mohamed Said El-azizi
    Mohamed Yehia Ahmed El-barmelgi
    Heba Azzam
    Egyptian Journal of Radiology and Nuclear Medicine, 53
  • [5] Diagnostic Accuracy of Three-Dimensional Endoanal Ultrasound for Anal Fistula: A Systematic Review and Meta-analysis
    Li, Jin
    Chen, Shao-Na
    Lin, Yun-Yong
    Zhu, Zhi-Min
    Ye, Da-Lin
    Chen, Fei
    Qiu, Shao-Dong
    TURKISH JOURNAL OF GASTROENTEROLOGY, 2021, 32 (11): : 913 - 922
  • [6] Comparison of MRI and Endoanal Ultrasound in Assessing Intersphincteric, Transsphincteric, and Suprasphincteric Perianal Fistula
    Akhoundi, Neda
    Bozchelouei, Javad Komijani
    Abrishami, Alireza
    Frootan, Mojgan
    Siami, Alireza
    Alimadadi, Elahe
    Saba, Gholamreza Bagherzadeh
    Rezazadeh, Elmira
    Amerifar, Maryam
    Eghdami, Ebrahim
    JOURNAL OF ULTRASOUND IN MEDICINE, 2023, 42 (09) : 2057 - 2064
  • [7] Diagnostic accuracy of ultrasound for the assessment of Baker’s cysts: a meta-analysis
    Ke Liu
    Xiaoxiao Li
    Qianlin Weng
    Guanghua Lei
    Ting Jiang
    Journal of Orthopaedic Surgery and Research, 17
  • [8] Diagnostic accuracy of ultrasound for the assessment of Baker's cysts: a meta-analysis
    Liu, Ke
    Li, Xiaoxiao
    Weng, Qianlin
    Lei, Guanghua
    Jiang, Ting
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2022, 17 (01)
  • [9] Diagnostic precision of endoanal MRI in the detection of anal sphincter pathology—a meta-analysis
    Emile Tan
    Ann Anstee
    Dow-Mu Koh
    Wadyslaw Gedroyc
    Paris P. Tekkis
    International Journal of Colorectal Disease, 2008, 23 : 641 - 651
  • [10] Diagnostic precision of endoanal MRI in the detection of anal sphincter pathology - a meta-analysis
    Tan, Emile
    Anstee, Ann
    Koh, Dow-Mu
    Gedroyc, Wadyslaw
    Tekkis, Paris P.
    INTERNATIONAL JOURNAL OF COLORECTAL DISEASE, 2008, 23 (06) : 641 - 651