Time-resolved QA and brachytherapy applicator commissioning: Towards the clinical implementation

被引:5
|
作者
Fonseca, Gabriel P. [1 ]
Voncken, Robert [1 ]
Hermans, Joep [1 ]
Verhaegen, Frank [1 ]
机构
[1] Maastricht Univ Med Ctr, GROW Sch Oncol & Dev Biol, Dept Radiat Oncol MAASTRO, Maastricht, Netherlands
关键词
Applicator commissioning; Imaging panel; Time-resolved QA; DOSE-RATE BRACHYTHERAPY; RING APPLICATORS; UNCERTAINTIES; MULTICENTER;
D O I
10.1016/j.brachy.2021.08.003
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
PURPOSE: Brachytherapy has a busy workflow relying on manual steps to ensure accurate delivery of the treatment. Systematic treatment errors have been reported due to faulty equipment, inadequate quality assurance (QA) and applicator commissioning methods. This study describes the use of a novel method, the Iridium Imaging System for QA (IrIS - QA), to automate and improve the applicator commissioning for HDR 192 Ir brachytherapy. METHODS AND MATERIALS: A 3D printed holder attached to an Imaging Panel (IP) has been developed to: (1) acquire a high-definition projection of the applicator using the gamma rays of the 192 Ir source for imaging; (2) Track the source within the applicator verifying in a time-resolved manner the dwell positions and dwell times with a high resolution. Results obtained for two applicator models are described in this manuscript. RESULTS: IrIS-QA is capable of measuring the dwell times with an accuracy better than 0.1 s and interdwell distances with submillimetre precision. The applicators tested in the study showed good agreement between planned and delivered dwell times and positions, with mean and maximum dwell position deviations below 0.5 mm and 1.3 mm, respectively. Dwell time measurements showed agreement superior to 0.05 s except for the first dwell position for which up to 0.15 s differences were observed. CONCLUSIONS: IrIS-QA is a compact system that includes many features necessary to improve the accuracy and efficiency of applicator commissioning and daily QA. No commercial system exists with similar capabilities. IrIS-QA is intended to replace current clinical procedures using film dosimetry. (c) 2021 Published by Elsevier Inc. on behalf of American Brachytherapy Society.
引用
收藏
页码:128 / 137
页数:10
相关论文
共 50 条
  • [41] CAN BRACHYTHERAPY ERRORS AND ACCIDENTS BE IDENTIFIED BY USING ONLINE IN VIVO TIME-RESOLVED LUMINESCENCE DOSIMETRY?
    Andersen, C.
    Nielsen, S.
    Lindegaard, J. C.
    Tanderup, K.
    RADIOTHERAPY AND ONCOLOGY, 2008, 88 : S159 - S160
  • [42] Towards Table-top Time-resolved Extreme Ultraviolet Fourier Holography
    Malm, Erik B.
    Wachulak, Przemyslaw W.
    Rocca, Jorge J.
    Menoni, Carmen S.
    Marconi, Mario C.
    2011 IEEE PHOTONICS CONFERENCE (PHO), 2011, : 841 - +
  • [43] Short X-ray pulse generation towards time-resolved spectroscopy
    Uesugi, N
    Nakano, H
    Nisikawa, T
    Oguri, K
    ICONO 2001: ULTRAFAST PHENOMENA AND STRONG LASER FIELDS, 2002, 4752 : 195 - 204
  • [44] Crossing the Border towards Deep UV Time-Resolved Microscopy of Native Fluophores
    Koenig, Marcelle
    Tannert, Sebastian
    Schoenau, Thomas
    Lauritsen, Kristian
    Koberling, Felix
    Erdmann, Rainer
    Beyreiss, Reinhild
    Nagel, Stefan
    Belder, Detlev
    BIOPHYSICAL JOURNAL, 2013, 104 (02) : 667A - 667A
  • [45] Towards time-resolved structural studies of tryptophan 2,3-dioxygenase
    Bailey, A.
    ACTA CRYSTALLOGRAPHICA A-FOUNDATION AND ADVANCES, 2022, 78 : E403 - E403
  • [46] Crossing the border towards deep UV time-resolved microscopy of native fluorophores
    Orthaus, S.
    Konig, M.
    Tannert, S.
    Schonau, T.
    Lauritsen, K.
    Koberling, F.
    Erdmann, R.
    Beyreiss, R.
    Nagl, S.
    Belder, D.
    EUROPEAN BIOPHYSICS JOURNAL WITH BIOPHYSICS LETTERS, 2013, 42 : S104 - S104
  • [47] Commissioning and quality assurance for VMAT delivery systems: An efficient time-resolved system using real-time EPID imaging
    Zwan, Benjamin J.
    Barnes, Michael P.
    Hindmarsh, Jonathan
    Lim, Seng B.
    Lovelock, Dale M.
    Fuangrod, Todsaporn
    O'Connor, Daryl J.
    Keall, Paul J.
    Greer, Peter B.
    MEDICAL PHYSICS, 2017, 44 (08) : 3909 - 3922
  • [48] Towards highly accelerated Cartesian time-resolved 3D flow cardiovascular magnetic resonance in the clinical setting
    Daniel Giese
    James Wong
    Gerald F Greil
    Martin Buehrer
    Tobias Schaeffter
    Sebastian Kozerke
    Journal of Cardiovascular Magnetic Resonance, 16
  • [49] Towards highly accelerated Cartesian time-resolved 3D flow cardiovascular magnetic resonance in the clinical setting
    Giese, Daniel
    Wong, James
    Greil, Gerald F.
    Buehrer, Martin
    Schaeffter, Tobias
    Kozerke, Sebastian
    JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2014, 16
  • [50] Dual-wavelength time-resolved optical mammograph for clinical studies
    Cubeddu, R
    Giambattistelli, E
    Pifferi, A
    Taroni, P
    Torricelli, A
    PHOTON MIGRATION, OPTICAL COHERENCE TOMOGRAPHY, AND MICROSCOPY, 2001, 4431 : 195 - 198