Commissioning and quality assurance for VMAT delivery systems: An efficient time-resolved system using real-time EPID imaging

被引:10
|
作者
Zwan, Benjamin J. [1 ,2 ]
Barnes, Michael P. [3 ,4 ]
Hindmarsh, Jonathan [1 ]
Lim, Seng B. [5 ]
Lovelock, Dale M. [5 ]
Fuangrod, Todsaporn [3 ]
O'Connor, Daryl J. [2 ]
Keall, Paul J. [6 ]
Greer, Peter B. [2 ,3 ]
机构
[1] Gosford Hosp, Cent Coast Canc Ctr, Gosford, NSW 2250, Australia
[2] Univ Newcastle, Sch Math & Phys Sci, Newcastle, NSW 2308, Australia
[3] Calvary Mater Hosp, Dept Radiat Oncol, Newcastle, NSW 2298, Australia
[4] Univ Newcastle, Sch Med Radiat Sci, Newcastle, NSW 2308, Australia
[5] Mem Sloan Kettering Canc Ctr, Dept Med Phys, New York, NY 10065 USA
[6] Univ Sydney, Sydney Med Sch, Radiat Phys Lab, Sydney, NSW 2006, Australia
关键词
commissioning; EPID; MLC; quality assurance; VMAT; VOLUMETRIC MODULATED ARC; DYNAMIC MULTILEAF COLLIMATOR; RADIATION-THERAPY; POSITIONAL ERRORS; GANTRY ANGLE; INDEPENDENT VERIFICATION; CLINICAL-PRACTICE; CINE-MODE; IMRT; QA;
D O I
10.1002/mp.12387
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: An ideal commissioning and quality assurance (QA) program for Volumetric Modulated Arc Therapy (VMAT) delivery systems should assess the performance of each individual dynamic component as a function of gantry angle. Procedures within such a program should also be time-efficient, independent of the delivery system and be sensitive to all types of errors. The purpose of this work is to develop a system for automated time-resolved commissioning and QA of VMAT control systems which meets these criteria. Methods: The procedures developed within this work rely solely on images obtained, using an electronic portal imaging device (EPID) without the presence of a phantom. During the delivery of specially designed VMAT test plans, EPID frames were acquired at 9.5Hz, using a frame grabber. The set of test plans was developed to individually assess the performance of the dose delivery and multileaf collimator (MLC) control systems under varying levels of delivery complexities. An in-house software tool was developed to automatically extract features from the EPID images and evaluate the following characteristics as a function of gantry angle: dose delivery accuracy, dose rate constancy, beam profile constancy, gantry speed constancy, dynamic MLC positioning accuracy, MLC speed and acceleration constancy, and synchronization between gantry angle, MLC positioning and dose rate. Machine log files were also acquired during each delivery and subsequently compared to information extracted from EPID image frames. Results: The largest difference between measured and planned dose at any gantry angle was 0.8% which correlated with rapid changes in dose rate and gantry speed. For all other test plans, the dose delivered was within 0.25% of the planned dose for all gantry angles. Profile constancy was not found to vary with gantry angle for tests where gantry speed and dose rate were constant, however, for tests with varying dose rate and gantry speed, segments with lower dose rate and higher gantry speed exhibited less profile stability. MLC positional accuracy was not observed to be dependent on the degree of interdigitation. MLC speed was measured for each individual leaf and slower leaf speeds were shown to be compensated for by lower dose rates. The test procedures were found to be sensitive to 1mm systematic MLC errors, 1mm random MLC errors, 0.4mm MLC gap errors and synchronization errors between the MLC, dose rate and gantry angle controls systems of 1 degrees. In general, parameters measured by both EPID and log files agreed with the plan, however, a greater average departure from the plan was evidenced by the EPID measurements. Conclusion: QA test plans and analysis methods have been developed to assess the performance of each dynamic component of VMAT deliveries individually and as a function of gantry angle. This methodology relies solely on time-resolved EPID imaging without the presence of a phantom and has been shown to be sensitive to a range of delivery errors. The procedures developed in this work are both comprehensive and time-efficient and can be used for streamlined commissioning and QA of VMAT delivery systems.
引用
收藏
页码:3909 / 3922
页数:14
相关论文
共 50 条
  • [1] Time-resolved beam symmetry measurement for VMAT commissioning and quality assurance
    Barnes, Michael P.
    Greer, Peter B.
    [J]. JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2016, 17 (02): : 220 - 230
  • [2] A real-time quality assurance monitor for validation of VMAT delivery
    Smale, J. R.
    Norrlinger, B.
    Jaffray, D.
    Heaton, R.
    Huang, C.
    Ivanovski, J.
    Galbraith, D.
    Islam, M.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2008, 72 (01): : S672 - S672
  • [3] Toward real-time verification for MLC tracking treatments using time-resolved EPID imaging
    Zwan, Benjamin J.
    Caillet, Vincent
    Booth, Jeremy T.
    Colvill, Emma
    Fuangrod, Todsaporn
    O'Brien, Ricky
    Briggs, Adam
    O'Connor, Daryl J.
    Keall, Paul J.
    Greer, Peter B.
    [J]. MEDICAL PHYSICS, 2021, 48 (03) : 953 - 964
  • [4] Feasibility of Time-Resolved DVH Based Treatment Delivery Verification of VMAT with EPID
    Greer, P.
    David, R.
    Wolf, J.
    [J]. MEDICAL PHYSICS, 2021, 48 (06)
  • [5] Time-resolved dosimetry using a pinpoint ionization chamber as quality assurance for IMRT and VMAT
    Louwe, Robert J. W.
    Wendling, Markus
    Monshouwer, Rene
    Satherley, Thomas
    Day, Rebecca A.
    Greig, Lynne
    [J]. MEDICAL PHYSICS, 2015, 42 (04) : 1625 - 1639
  • [6] An error detection method for real-time EPID-based treatment delivery quality assurance
    Alves, Victor Gabriel Leandro
    Ahmed, Mahmoud
    Aliotta, Eric
    Choi, Wookjin
    Siebers, Jeffrey Vincent
    [J]. MEDICAL PHYSICS, 2021, 48 (02) : 569 - 578
  • [7] Real-Time EPID-Based Detection Metric For VMAT Delivery Errors
    Passarge, M.
    Fix, M. K.
    Manser, P.
    Stampanoni, M. F. M.
    Siebers, J. V.
    [J]. MEDICAL PHYSICS, 2016, 43 (06) : 3713 - 3713
  • [8] A novel and independent method for time-resolved gantry angle quality assurance for VMAT
    Fuangrod, Todsaporn
    Greer, Peter B.
    Zwan, Benjamin J.
    Barnes, Michael P.
    Lehmann, Joerg
    [J]. JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2017, 18 (05): : 134 - 142
  • [9] Detection of Subtle Non-Gross VMAT Plan Delivery Errors Via Real-Time EPID Imaging
    Alves, V. Leandro
    Aliotta, E.
    Nourzadeh, H.
    Ahmed, M.
    Siebers, J.
    [J]. MEDICAL PHYSICS, 2019, 46 (06) : E352 - E353
  • [10] QUALITY ASSURANCE OF REAL-TIME BRACHYTHERAPY PLANNING AND DELIVERY
    Al-Qaisieh, B.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2010, 96 : S56 - S56