A CCD-based detector for SPECT

被引:0
|
作者
Nagarkar, VV [1 ]
Shestakova, I [1 ]
Gaysinskiy, V [1 ]
Tipnis, SV [1 ]
Singh, B [1 ]
Barber, W [1 ]
Hasegawa, B [1 ]
Entine, G [1 ]
机构
[1] Radiat Monitoring Devices Inc, Watertown, MA 02472 USA
关键词
D O I
暂无
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
We are investigating the use of a CCD for high-resolution radionuclide imaging. The use of a CCD has the potential to provide very high spatial resolution on the order of 200 to 400 gm, while significantly simplifying the readout electronics. The detector is based on a special CCD with on-chip multiplication gain that allows high-speed operation while maintaining the read noise at a very low level of < 1 electron. To achieve high detection efficiency and excellent spatial resolution for incident gamma flux, a specially fabricated thick microcolumnar CsI(TI) scintillator was optically coupled to the CCD. A prototype SPECT imaging system was assembled by incorporating pinhole/parallel hole collimators in the design. The use of this system for radionuclide imaging has been demonstrated through tomographic imaging of a test phantom filled with Tc-99m.
引用
收藏
页码:2449 / 2452
页数:4
相关论文
共 50 条
  • [21] A CCD-based γ-ray dosimeter
    Harris, EJ
    Royle, GJ
    Mooney, MJ
    Speller, RD
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2001, 458 (1-2): : 227 - 232
  • [22] The swept charge device, a novel CCD-based EDX detector: first results
    Lowe, BG
    Holland, AD
    Hutchinson, IB
    Burt, DJ
    Pool, PJ
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2001, 458 (1-2): : 568 - 579
  • [23] PERFORMANCE LIMITS OF PLASTIC SCINTILLATION DETECTOR CCD-BASED DOSIMETERS USING CURRENT TECHNOLOGY
    Lacroix, F.
    Beddar, S.
    Gingras, L.
    Beaulieu, L.
    RADIOTHERAPY AND ONCOLOGY, 2009, 92 : S151 - S151
  • [24] Realization of systems with CCD-based measurements
    Looze, DP
    AUTOMATICA, 2005, 41 (11) : 2005 - 2009
  • [25] AREA DETECTOR DESIGN .2. APPLICATION TO A MODULAR CCD-BASED DETECTOR FOR X-RAY CRYSTALLOGRAPHY
    STANTON, M
    PHILLIPS, WC
    OMARA, D
    NADAY, I
    WESTBROOK, E
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1993, 325 (03): : 558 - 567
  • [26] 2 CCD-BASED DETECTOR SYSTEMS FOR USE IN ELECTRON-MICROSCOPY AND RELATED TECHNIQUES
    CHAPMAN, JN
    GLAS, F
    ROBERTS, PTE
    INSTITUTE OF PHYSICS CONFERENCE SERIES, 1982, (61): : 131 - 134
  • [27] Development of large area CCD-based X-ray detector for macromolecular crystallography
    Pokric, M
    Allinson, NM
    Jorden, AR
    Cox, MP
    Marshall, A
    Long, PG
    Moon, K
    Jerram, P
    Pool, P
    Nave, C
    Derbyshire, GE
    Helliwell, JR
    DETECTORS FOR CRYSTALLOGRAPHY AND DIFFRACTION STUDIES AT SYNCHROTRON SOURCES, 1999, 3774 : 46 - 57
  • [28] CCD-based magnetic field imaging
    O, N
    Nathan, A
    IEEE TRANSACTIONS ON ELECTRON DEVICES, 1997, 44 (10) : 1653 - 1657
  • [29] A CCD-BASED PARALLEL ANALOG PROCESSOR
    JOSEPH, JD
    ROBERTS, PCT
    HOSCHETTE, JA
    HANZAL, BR
    SCHWANEBECK, JC
    PROCEEDINGS OF THE SOCIETY OF PHOTO-OPTICAL INSTRUMENTATION ENGINEERS, 1984, 501 : 238 - 241
  • [30] CCD-based method of level measurement
    Song, Hua
    Meng, Xiaofeng
    Yi Qi Yi Biao Xue Bao/Chinese Journal of Scientific Instrument, 2002, 23 (02):