A new method fast measure cryogenic vessel heat leakage

被引:1
|
作者
Li, Zheng-Qing [1 ]
Li, Xiao-Jin [1 ]
Liu, Mo [2 ]
机构
[1] Lanzhou Inst Phys, Lanzhou, Peoples R China
[2] Beijing Inst Spacecraft Environm Engn, Beijing, Peoples R China
来源
关键词
cryogenic vessel; heat leakage; evaporation rate; measurement; fast; PRESSURE CONTROL;
D O I
10.9714/psac.2020.22.1.024
中图分类号
O59 [应用物理学];
学科分类号
摘要
Heat leakage is an important parameter to reflect heat insulated performance of cryogenic vessel. According to the current standard requirements, it needs to measure the daily evaporation rate to indicate heat leakage. The test needs-over 24h after cryogenic vessel in heat equilibrium as standard required, therefore test efficiency is poor and new efficient method is required to cut test time. First of all, the volume of instantaneous evaporated gas and heat leakage are calculated by the current standard corresponding to the maximum allowable daily evaporation rate of cryogenic vessel. Depending on the relationship between real daily evaporation rate and maximum allowable daily evaporation rate of cryogenic vessel, we designed a new test method based on the pressure changes over time in cryogenic vessel to determine whether its heat insulated performance meets requirements or not. Secondly, the heat transfer process was analyzed in measurement of cryogenic vessel, and the heat transfer equations of whole system were established. Finally, the test was completed in four hours; meanwhile the heat leakage and daily evaporation rate of cryogenic vessel are calculated basing on test data.
引用
收藏
页码:24 / 28
页数:5
相关论文
共 50 条
  • [41] Characterization of chaos - A new, fast, and effective measure
    Sideris, IV
    NONLINEAR DYNAMICS IN ASTRONOMY AND PHYSICS: IN MEMORY OF HENRY E. KANDRUP, 2005, 1045 : 79 - 92
  • [42] ;A Fast Active Leakage Cancellation Method for UHF RFID Readers
    Kapucu, Kerem
    Pauli, Muriel
    Dehollain, Catherine
    2017 IEEE INTERNATIONAL CONFERENCE ON RFID (RFID), 2017,
  • [43] A fast POD prediction method for hydrogen leakage at different pressures
    Chen, Guang
    Qi, Baojin
    Hu, Weipeng
    Zhang, Yonghai
    Wei, Jinjia
    INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2024, 49 : 1391 - 1404
  • [44] New method to measure printability
    不详
    PAPERI JA PUU-PAPER AND TIMBER, 2007, 89 (03): : 140 - 140
  • [45] New method of constructing measure
    Liu, Guo-Qing
    Journal of Harbin Institute of Technology (New Series), 2007, 14 (05) : 703 - 704
  • [46] NEW FAST-RESPONDING OPTICAL METHOD TO MEASURE PCO2 IN GASES AND SOLUTIONS
    OPITZ, N
    LUBBERS, DW
    PFLUGERS ARCHIV-EUROPEAN JOURNAL OF PHYSIOLOGY, 1975, 355 : R120 - R120
  • [47] New method to measure the rise time of a fast pulse slicer for laser ion acceleration research
    Mori, Michiaki
    Yogo, Akifumi
    Kiriyama, Hiromitsu
    Nishiuchi, Mamiko
    Ogura, Koichi
    Orimo, Satoshi
    Ma, Jinglong
    Sagisaka, Akito
    Kanazawa, Shuhei
    Kondo, Shuji
    Nakai, Yoshiki
    Akutsu, Atsushi
    Yamamoto, Yoichi
    Shimomura, Takuya
    Tanoue, Manabu
    Nakamura, Shu
    Shirai, Toshiyuki
    Iwashita, Yoshihisa
    Noda, Akira
    Oshi, Yuji
    Nayuki, Takuya
    Fujii, Takashi
    Nemoto, Koshichi
    Choi, Il Woo
    Yu, Tae Jun
    Ko, Do-Kyeong
    Lee, Jongmin
    Daido, Hiroyuki
    Esirkepov, Timur
    Bulanov, Sergei V.
    Bolton, Paul R.
    Kimura, Toyoaki
    IEEE TRANSACTIONS ON PLASMA SCIENCE, 2008, 36 (04) : 1872 - 1877
  • [48] Prediction method of pool boiling heat transfer with cryogenic liquids
    Gorenflo, D.
    Sokol, P.
    International Journal of Refrigeration, 1988, 11 (05) : 315 - 320
  • [49] Pressure vessel leakage detection method based on online acoustic emission signals
    Liu, Zhengjie
    Mu, Weilei
    Ning, Hao
    Wu, Mengmeng
    Liu, Guijie
    INSIGHT, 2023, 65 (01) : 36 - 42
  • [50] A new method for flow measurement in cryogenic systems
    Grohmann, S.
    CRYOGENICS, 2014, 60 : 9 - 18