摘要
Heat leakage is an important parameter to reflect heat insulated performance of cryogenic vessel. According to the current standard requirements, it needs to measure the daily evaporation rate to indicate heat leakage. The test needs-over 24h after cryogenic vessel in heat equilibrium as standard required, therefore test efficiency is poor and new efficient method is required to cut test time. First of all, the volume of instantaneous evaporated gas and heat leakage are calculated by the current standard corresponding to the maximum allowable daily evaporation rate of cryogenic vessel. Depending on the relationship between real daily evaporation rate and maximum allowable daily evaporation rate of cryogenic vessel, we designed a new test method based on the pressure changes over time in cryogenic vessel to determine whether its heat insulated performance meets requirements or not. Secondly, the heat transfer process was analyzed in measurement of cryogenic vessel, and the heat transfer equations of whole system were established. Finally, the test was completed in four hours; meanwhile the heat leakage and daily evaporation rate of cryogenic vessel are calculated basing on test data.
引用
收藏
页码:24 / 28
页数:5
相关论文
共 50 条
  • [21] A new calorimetric system to measure heat capacities of solids by the drop method
    Bernardes, Carlos E. S.
    Santos, Luis M. N. B. F.
    da Piedade, Manuel E. Minas
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2006, 17 (06) : 1405 - 1408
  • [22] A fast method to measure the evaporation rate
    Kumar, Navneet
    Arakeri, Jaywant H.
    JOURNAL OF HYDROLOGY, 2021, 594
  • [23] A CRYOGENIC COUETTE VISCOMETER TO MEASURE DISSIPATION AND HEAT TRANSFER DURING SOLIDIFICATION
    Leachman, J. W.
    Pfotenhauer, J. M.
    Nellis, G. F.
    Steiner, T. J.
    ADVANCES IN CRYOGENIC ENGINEERING, VOLS 55A AND 55B, 2010, 1218 : 329 - 336
  • [24] A proposed method for the determination of leakage rate for a reactor containment vessel
    Tries, MA
    Bobek, LM
    NUCLEAR TECHNOLOGY, 2004, 145 (03) : 319 - 323
  • [25] Estimating heat tolerance of plants by ion leakage: a new method based on gradual heating
    Ilik, Petr
    Spundova, Martina
    Sicner, Michal
    Melkovicova, Helena
    Kucerova, Zuzana
    Krchnak, Pavel
    Furst, Tomas
    Vecerova, Kristyna
    Panzarova, Klara
    Benediktyova, Zuzana
    Trtilek, Martin
    NEW PHYTOLOGIST, 2018, 218 (03) : 1278 - 1287
  • [26] SIMPLE AND ACCURATE NEW METHOD TO MEASURE SPECIFIC-HEAT AT ARBITRARY TEMPERATURE (QUOTIENT METHOD)
    MARX, R
    REVUE DE PHYSIQUE APPLIQUEE, 1978, 13 (06): : 298 - 303
  • [27] A new method to simultaneously measure local heat transfer and visualize flow boiling in plate heat exchanger
    Jin, Shenghan
    Hrnjak, Pega
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2017, 113 : 635 - 646
  • [28] A New Method to Measure Hubble Parameter H(z) Using Fast Radio Bursts
    Wu, Q.
    Yu, H.
    Wang, F. Y.
    ASTROPHYSICAL JOURNAL, 2020, 895 (01):
  • [29] New method and device to fast measure surface tension of the melt and its applications in foundry
    Shi, Dequan
    Li, Dayong
    Gao, Guili
    METALLURGICAL AND MATERIALS TRANSACTIONS B-PROCESS METALLURGY AND MATERIALS PROCESSING SCIENCE, 2008, 39 (01): : 46 - 55
  • [30] Cryogenic leakage risk analysis for FLNG and use of brittle crack arresting material as a risk mitigation measure
    Usami, Akio
    Kishimoto, Naohiko
    Kusumoto, Hiroki
    Kaneko, Fujio
    Inoue, Takehiro
    Transactions - Society of Naval Architects and Marine Engineers, 2016, 124 : 145 - 153