A new method fast measure cryogenic vessel heat leakage

被引:1
|
作者
Li, Zheng-Qing [1 ]
Li, Xiao-Jin [1 ]
Liu, Mo [2 ]
机构
[1] Lanzhou Inst Phys, Lanzhou, Peoples R China
[2] Beijing Inst Spacecraft Environm Engn, Beijing, Peoples R China
来源
关键词
cryogenic vessel; heat leakage; evaporation rate; measurement; fast; PRESSURE CONTROL;
D O I
10.9714/psac.2020.22.1.024
中图分类号
O59 [应用物理学];
学科分类号
摘要
Heat leakage is an important parameter to reflect heat insulated performance of cryogenic vessel. According to the current standard requirements, it needs to measure the daily evaporation rate to indicate heat leakage. The test needs-over 24h after cryogenic vessel in heat equilibrium as standard required, therefore test efficiency is poor and new efficient method is required to cut test time. First of all, the volume of instantaneous evaporated gas and heat leakage are calculated by the current standard corresponding to the maximum allowable daily evaporation rate of cryogenic vessel. Depending on the relationship between real daily evaporation rate and maximum allowable daily evaporation rate of cryogenic vessel, we designed a new test method based on the pressure changes over time in cryogenic vessel to determine whether its heat insulated performance meets requirements or not. Secondly, the heat transfer process was analyzed in measurement of cryogenic vessel, and the heat transfer equations of whole system were established. Finally, the test was completed in four hours; meanwhile the heat leakage and daily evaporation rate of cryogenic vessel are calculated basing on test data.
引用
收藏
页码:24 / 28
页数:5
相关论文
共 50 条
  • [1] Method applied to evaluate heat leakage of cryogenic vessel for liquid hydrogen
    Li, Zhengqing
    Yang, Shengsheng
    Wang, Xiaojun
    Yuan, Yafei
    PROGRESS IN SUPERCONDUCTIVITY AND CRYOGENICS, 2021, 23 (01): : 7 - 11
  • [2] Simple predictive heat leakage estimation of static non-vacuum insulated cryogenic vessel
    Mzad, Hocine
    PROGRESS IN SUPERCONDUCTIVITY AND CRYOGENICS, 2020, 22 (03): : 25 - 30
  • [3] Method to evaluate heat leakage of vertical cryogenic vessels at different liquid levels
    Li, Zheng-qing
    Yang, Sheng-sheng
    Wang, Xiao-jun
    Li, Xiao-xia
    JOURNAL OF MECHANICAL SCIENCE AND TECHNOLOGY, 2021, 35 (12) : 5733 - 5739
  • [4] Method for evaluating heat leakage in horizontal cryogenic vessels at any liquid level
    Li, Zhengqing
    Yang, Shengsheng
    Wang, Xiaojun
    JOURNAL OF THERMAL ANALYSIS AND CALORIMETRY, 2022, 147 (24) : 14917 - 14924
  • [5] Method for evaluating heat leakage in horizontal cryogenic vessels at any liquid level
    Zhengqing Li
    Shengsheng Yang
    Xiaojun Wang
    Journal of Thermal Analysis and Calorimetry, 2022, 147 : 14917 - 14924
  • [6] Method to evaluate heat leakage of vertical cryogenic vessels at different liquid levels
    Zheng-qing Li
    Sheng-sheng Yang
    Xiao-jun Wang
    Xiao-xia Li
    Journal of Mechanical Science and Technology, 2021, 35 : 5733 - 5739
  • [7] Using a new testing method to measure smoke leakage of existing doors
    National Taiwan University of Science and Technology, Taiwan
    不详
    J Appl Fire Sci, 2006, 1 (21-33): : 2006 - 2007
  • [8] Simulation and experimental research of heat leakage of cryogenic transfer lines
    Deng, B. C.
    Xie, X. J.
    Pan, W.
    Jiang, R. X.
    Li, J.
    Yang, S. Q.
    Li, Q.
    ADVANCES IN CRYOGENIC ENGINEERING, 2017, 278
  • [9] A new method to measure the real specific heat.
    Lindemann, FA
    Schweis, F
    PHYSIKALISCHE ZEITSCHRIFT, 1913, 14 : 766 - 767
  • [10] Experimental Study of Minimizing Heat Leakage of Cryogenic Transfer Lines
    Deng, Bicai
    Yang, Shaoqi
    Xie, Xiujuan
    Wang, Yunlong
    Li, Qing
    INNOVATIVE SOLUTIONS FOR ENERGY TRANSITIONS, 2019, 158 : 4778 - 4784