Advantages of reaction cell ICP-MS on doubly charged interferences for arsenic and selenium analysis in foods

被引:5
|
作者
Jackson, Brian P. [1 ]
Liba, Amir [2 ]
Nelson, Jenny [2 ]
机构
[1] Dartmouth Coll, Earth Sci, Trace Element Anal Core Lab, Hanover, NH 03755 USA
[2] Agilent Technol, Wilmington, DE USA
关键词
RARE-EARTH-ELEMENTS; BIOLOGICAL SAMPLES; RICE; SPECIATION; SE;
D O I
10.1039/c4ja00310a
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Recent reports of As concentrations in certain food and drinks have garnered public concern and led to a lowering of the US guideline maximum concentration for inorganic As in apple juice and proposed limits for As in rice products. In contrast Se is an essential micro-nutrient that can be limiting when Se-poor soils yield Se-poor food crops. Rare earth element (REE) doubly charged interferences on As and Se can be significant even when initial ICP-MS tuning minimizes doubly charged formation. We analyzed NIST 1547 (peach leaves) and 1515 (apple leaves), which contain high levels of REEs, by quadrupole ICP-MS with (He) collision mode, H-2 reaction mode or triple quadrupole ICP-MS (ICP-QQQ) in mass-shift mode (O-2 and O-2/H-2). Analysis by collision cell ICP-MS significantly over-estimated As and Se concentration due to REE doubly charged formation; mathematical correction increased the accuracy of analysis but is prone to error when analyte concentration and sensitivity is low and interferent is high. For Se, H-2 reaction mode was effective in suppressing Gd2+ leading to accurate determination of Se in both SRMs without the need for mathematical correction. ICP-QQQ using mass-shift mode for As+ from m/z 75 to AsO+ at m/z 91 and Se+ from m/z 78 to SeO+ at m/z 94 alleviated doubly charged effects and resulted in accurate determination of As and Se in both SRMs without the need for correction equations. Zr and Mo isobars at 91 and 94 were shown to be effectively rejected by the MS/MS capability of the ICP-QQQ.
引用
收藏
页码:1179 / 1183
页数:5
相关论文
共 50 条
  • [1] Advantages of reaction cell ICP-MS on doubly charged interferences for arsenic and selenium analysis in foods
    Jackson, Brian P. (Brian.P.Jackson@dartmouth.edu), 1600, Royal Society of Chemistry (30):
  • [2] Advantages of reaction cell ICP-MS for arsenic analysis and speciation
    Jackson, Brian
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2017, 254
  • [3] Attenuation of doubly charged ion interferences on arsenic and selenium by ICP-MS under low kinetic energy collision cell conditions with hydrogen cell gas
    Sugiyama, Naoki
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2021, 36 (02) : 294 - 302
  • [4] Advantages of dynamic reaction cell ICP-MS for geological analyses
    Neubauer, Kenneth
    Beres, Steven
    Dionne, Luc
    Green, Damon
    Plasma Source Mass Spectrometry: Current Trends and Future Developments, 2005, (301): : 111 - 119
  • [5] OXIDE AND DOUBLY CHARGED ION PEAKS IN ICP-MS
    VANDECASTEELE, C
    VANHAECKE, F
    VANHOE, H
    DAMS, R
    FRESENIUS ZEITSCHRIFT FUR ANALYTISCHE CHEMIE, 1989, 334 (07): : 682 - 682
  • [6] Advantages of dynamic bandpass tuning in dynamic reaction cell ICP-MS
    Latino, J
    Neubauer, K
    Wolf, RE
    Wallace, G
    Thomsen, M
    ATOMIC SPECTROSCOPY, 2001, 22 (03) : 306 - 311
  • [7] Determination of selenium in milk powder by octopole reaction cell ICP-MS
    Cho, Sung-Eel
    Kim, Mi-Ju
    Kim, Yong-Ha
    Min, Young-Keun
    Kim, Young-Sang
    ANALYTICAL SCIENCE AND TECHNOLOGY, 2006, 19 (03): : 203 - 210
  • [8] Reduction of polyatomic interferences in biological material using dynamic reaction cell ICP-MS
    Pick, Denis
    Leiterer, Matthias
    Einax, Juergen W.
    MICROCHEMICAL JOURNAL, 2010, 95 (02) : 315 - 319
  • [9] A new dynamic reaction cell for reducing ICP-MS interferences using chemical resolution
    Denoyer, ER
    Tanner, SD
    Voellkopf, U
    SPECTROSCOPY, 1999, 14 (02) : 43 - +