Advantages of reaction cell ICP-MS on doubly charged interferences for arsenic and selenium analysis in foods

被引:5
|
作者
Jackson, Brian P. [1 ]
Liba, Amir [2 ]
Nelson, Jenny [2 ]
机构
[1] Dartmouth Coll, Earth Sci, Trace Element Anal Core Lab, Hanover, NH 03755 USA
[2] Agilent Technol, Wilmington, DE USA
关键词
RARE-EARTH-ELEMENTS; BIOLOGICAL SAMPLES; RICE; SPECIATION; SE;
D O I
10.1039/c4ja00310a
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Recent reports of As concentrations in certain food and drinks have garnered public concern and led to a lowering of the US guideline maximum concentration for inorganic As in apple juice and proposed limits for As in rice products. In contrast Se is an essential micro-nutrient that can be limiting when Se-poor soils yield Se-poor food crops. Rare earth element (REE) doubly charged interferences on As and Se can be significant even when initial ICP-MS tuning minimizes doubly charged formation. We analyzed NIST 1547 (peach leaves) and 1515 (apple leaves), which contain high levels of REEs, by quadrupole ICP-MS with (He) collision mode, H-2 reaction mode or triple quadrupole ICP-MS (ICP-QQQ) in mass-shift mode (O-2 and O-2/H-2). Analysis by collision cell ICP-MS significantly over-estimated As and Se concentration due to REE doubly charged formation; mathematical correction increased the accuracy of analysis but is prone to error when analyte concentration and sensitivity is low and interferent is high. For Se, H-2 reaction mode was effective in suppressing Gd2+ leading to accurate determination of Se in both SRMs without the need for mathematical correction. ICP-QQQ using mass-shift mode for As+ from m/z 75 to AsO+ at m/z 91 and Se+ from m/z 78 to SeO+ at m/z 94 alleviated doubly charged effects and resulted in accurate determination of As and Se in both SRMs without the need for correction equations. Zr and Mo isobars at 91 and 94 were shown to be effectively rejected by the MS/MS capability of the ICP-QQQ.
引用
收藏
页码:1179 / 1183
页数:5
相关论文
共 50 条
  • [31] Determination of Toxic Elements and Arsenic Species in Salted Foods and Sea Salt by ICP-MS and HPLC-ICP-MS
    Hwang, In Min
    Lee, Hee Min
    Lee, Hae-Won
    Jung, Ji-Hye
    Moon, Eun Woo
    Khan, Naeem
    Kim, Sung Hyun
    ACS OMEGA, 2021, 6 (30): : 19427 - 19434
  • [32] Analysis of arsenic in rice grains using ICP-MS and fs LA-ICP-MS
    Park, K.S. (pks6475@kist.re.kr), 1600, Royal Society of Chemistry (29):
  • [33] Effects of deuterium in octopole reaction and collision cell ICP-MS on detection of selenium in extracellular fluids
    Ogra, Y
    Ishiwata, K
    Suzuki, KT
    ANALYTICA CHIMICA ACTA, 2005, 554 (1-2) : 123 - 129
  • [34] Analysis of arsenic in rice grains using ICP-MS and fs LA-ICP-MS
    Choi, Sung Hwa
    Kim, Jae Sung
    Lee, Ji Yeon
    Jeon, Ji Suk
    Kim, Ju Wan
    Russo, Richard E.
    Gonzalez, Jhanis
    Yoo, Jong Hyun
    Kim, Kyong Su
    Yang, Jung Seok
    Park, Kyung Su
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2014, 29 (07) : 1233 - 1237
  • [35] ICP-MS analysis of trace selenium in the Great Salt Lake
    Moellmer, William O.
    Miller, Theron G.
    Wilbur, Steve
    Soffey, Emmett
    Spectroscopy (Santa Monica), 2007, 22 (01) : 32 - 41
  • [36] ICP-MS analysis of trace selenium in the Great Salt Lake
    Moellmer, William O.
    Miller, Theron G.
    Wilbur, Steve
    Soffey, Emmett
    SPECTROSCOPY, 2007, 22 (01) : 32 - +
  • [37] Determination of selenium in biological materials by isotope dilution analysis with an octapole reaction system ICP-MS
    García Alonso, J.I. (jiga@sauron.quimica.uniovi.es), 1600, Royal Society of Chemistry (18):
  • [38] Determination of selenium in biological materials by isotope dilution analysis with an octapole reaction system ICP-MS
    Reyes, LH
    Gayón, JMM
    Alonso, JIG
    Sanz-Medel, A
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2003, 18 (01) : 11 - 16
  • [39] The benefits of a dynamic reaction cell to remove carbon- and chloride-based spectral interferences by ICP-MS
    Neubauer, K
    Völlkopf, U
    ATOMIC SPECTROSCOPY, 1999, 20 (02) : 64 - 68
  • [40] Reaction chemistry and collisional processes in multipole devices for resolving isobaric interferences in ICP-MS
    Bandura, DR
    Baranov, VI
    Tanner, SD
    FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 2001, 370 (05) : 454 - 470