Optimized ultrasonic assisted extraction-dispersive liquid-liquid microextraction coupled with gas chromatography for determination of essential oil of Oliveria decumbens Vent.

被引:76
|
作者
Sereshti, Hassan [1 ]
Izadmanesh, Yahya [1 ]
Samadi, Soheila [1 ]
机构
[1] Univ Tehran, Sch Chem, Univ Coll Sci, Tehran, Iran
关键词
Oliveria decumbens Vent; Ultrasonic assisted extraction; Dispersive liquid-liquid microextraction; Experimental design; Gas chromatography; Essential oil; ATOMIC-ABSORPTION-SPECTROMETRY; SOLID-PHASE MICROEXTRACTION; SINGLE-DROP MICROEXTRACTION; FREE MICROWAVE EXTRACTION; THYMUS-VULGARIS L; MASS-SPECTROMETRY; WATER SAMPLES; RAPID-DETERMINATION; VOLATILE FRACTION; SENSITIVE METHOD;
D O I
10.1016/j.chroma.2011.05.037
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Ultrasonic assisted extraction-dispersive liquid-liquid microextraction (UAE-DLLME) coupled with gas chromatography (GC) was applied for extraction and determination of essential oil constituents of the plant Oliveria decumbens Vent. Scanning electron microscopy (SEM) was used to see the effect of ultrasonic radiation on the extraction efficiency. By comparison with hydrodistillation. UAE-DLLME is fast, low cost, simple, efficient and consuming small amount of plant materials (similar to 1.0 g). The effects of various parameters such as temperature, ultrasonication time, volume of disperser and extraction solvents were investigated by a full factorial design to identify significant variables and their interactions. The results demonstrated that temperature and ultrasonication time had no considerable effect on the results. In the next step, a central composite design (CCD) was performed to obtain the optimum levels of significant parameters. The obtained optimal conditions were: 0.45 mL for disperser solvent (acetonitrile) and 94.84 mu L for extraction solvent (chlorobenzene). The limits of detection (LODs), linear dynamic range and determination coefficients (R-2) were 0.2-29 ng mL(-1), 1-2100 ng mL(-1) and 0.995-0.998, respectively. The main components of the essential oil were: thymol (47.06%), carvacrol (23.31%), gamma-terpinene (18.94%), p-cymene (8.71%), limonene (0.76%) and myristicin (0.63%). (C) 2011 Elsevier B.V. All rights reserved.
引用
收藏
页码:4593 / 4598
页数:6
相关论文
共 50 条
  • [41] Dispersive Liquid-Liquid Microextraction Method Coupled with Gas Chromatography for Determination of Chlorothalonil, Captan and Folpet Residues in Grape Samples
    Zhou Xin
    Zang Xiao-Huan
    Wang Dong-Yue
    Cui Peng-Lei
    Wang Zhi
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2009, 37 (01) : 41 - 45
  • [42] Determination of Phthalates in Milk by Ultrasound-Assisted Dispersive Liquid-Liquid Microextraction and Gas Chromatography-Mass Spectrometry
    Tuncel, Semra G.
    Senlik, Damla
    ANALYTICAL LETTERS, 2016, 49 (09) : 1334 - 1343
  • [43] Gas Purge Microsyringe Extraction Coupled with Dispersive Liquid-Liquid Microextraction for the Determination of Acidic Compounds in Food Packaging Materials
    Shijuan Zhang
    Cuncun Sheng
    Jiangchunzi Zhang
    Yanxin Li
    Jinmao You
    Food Analytical Methods, 2017, 10 : 1164 - 1171
  • [44] Gas Purge Microsyringe Extraction Coupled with Dispersive Liquid-Liquid Microextraction for the Determination of Acidic Compounds in Food Packaging Materials
    Zhang, Shijuan
    Sheng, Cuncun
    Zhang, Jiangchunzi
    Li, Yanxin
    You, Jinmao
    FOOD ANALYTICAL METHODS, 2017, 10 (05) : 1164 - 1171
  • [45] Simultaneous Determination of Sulfonamides Antibiotics in Environmental Water and Seafood Samples Using Ultrasonic-Assisted Dispersive Liquid-Liquid Microextraction Coupled with High Performance Liquid Chromatography
    Wang, Yixiao
    Li, Jinhua
    Ji, Ling
    Chen, Lingxin
    MOLECULES, 2022, 27 (07):
  • [46] Rapid determination of pyrethroids in tomatoes using gas chromatography combined with dispersive liquid-liquid microextraction
    Li Xianbo
    Zhao Man
    Li Shengqing
    Chen Hao
    Shen Jing
    CHINESE JOURNAL OF CHROMATOGRAPHY, 2012, 30 (09) : 926 - 930
  • [47] Dispersive Liquid-Liquid Microextraction Coupled with High Performance Liquid Chromatography for the Determination of Nonylphenol in Environmental Water Samples
    Yang, Yingchun
    Mo, Li
    Wang, Jinmei
    Wang, Mingwei
    Zhou, Shiyu
    CONFERENCE ON ENVIRONMENTAL POLLUTION AND PUBLIC HEALTH, VOL 1-2, 2010, : 875 - 878
  • [48] Determination of Triazine Herbicides in Environmental Samples by Dispersive Liquid-Liquid Microextraction Coupled with High Performance Liquid Chromatography
    Wang, Chun
    Ji, Shujing
    Wu, Qiuhua
    Wu, Chunxia
    Wang, Zhi
    JOURNAL OF CHROMATOGRAPHIC SCIENCE, 2011, 49 (09) : 689 - 694
  • [49] Rapid determination of polycyclic aromatic hydrocarbons in grilled meat using microwave-assisted extraction and dispersive liquid-liquid microextraction coupled to gas chromatography-mass spectrometry
    Kamankesh, Marzieh
    Mohammadi, Abdorreza
    Hosseini, Hedayat
    Tehrani, Zohreh Modarres
    MEAT SCIENCE, 2015, 103 : 61 - 67
  • [50] Determination of four bisphenols in plastic packaging beverages by ultrasonic-assisted dispersive liquid-liquid microextraction
    Meng, Wei
    Li, Hongmei
    Wang, Kaiqing
    Cao, Yanqiu
    PACKAGING TECHNOLOGY AND SCIENCE, 2022, 35 (10) : 753 - 764