Highly sensitive colorimetric detection of glucose and uric acid in biological fluids using chitosan-modified paper microfluidic devices

被引:153
|
作者
Gabriel, Ellen F. M. [1 ]
Garcia, Paulo T. [1 ]
Cardoso, Thiago M. G. [1 ]
Lopes, Flavio M. [2 ]
Martins, Felipe T. [1 ]
Coltro, Wendell K. T. [1 ]
机构
[1] Univ Fed Goias, Inst Quim, BR-74690900 Goiania, Go, Brazil
[2] Univ Fed Goias, Fac Farm, BR-74605170 Goiania, Go, Brazil
关键词
ELECTROCHEMISTRY; NANOPARTICLES; SMARTPHONE; PLATFORMS; SURFACE;
D O I
10.1039/c6an00430j
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This paper describes the modification of microfluidic paper-based analytical devices (mu PADs) with chitosan to improve the analytical performance of colorimetric measurements associated with enzymatic bioassays. Chitosan is a natural biopolymer extensively used to modify biosensing surfaces due to its capability of providing a suitable microenvironment for the direct electron transfer between an enzyme and a reactive surface. This hypothesis was investigated using glucose and uric acid (UA) colorimetric assays as model systems. The best colorimetric sensitivity for glucose and UA was achieved using a chromogenic solution composed of 4-aminoantipyrine and sodium 3,5-dichloro-2-hydroxy-benzenesulfonate (4-AAP/DHBS), which provided a linear response for a concentration range between 0.1 and 1.0 mM. Glucose and UA were successfully determined in artificial serum samples with accuracies between 87 and 114%. The limits of detection (LODs) found for glucose and UA assays were 23 and 37 mu M, respectively. The enhanced analytical performance of chitosan-modified mu PADs allowed the colorimetric detection of glucose in tear samples from four nondiabetic patients. The achieved concentration levels ranged from 130 to 380 mu M. The modified mu PADs offered analytical reliability and accuracy as well as no statistical difference from the values achieved through a reference method. Based on the presented results, the proposed mu PAD can be a powerful alternative tool for non-invasive glucose analysis.
引用
收藏
页码:4749 / 4756
页数:8
相关论文
共 50 条
  • [41] A Biocompatible, Highly Sensitive, and Non-Enzymatic Glucose Electrochemical Sensor Based on a Copper-Cysteamine (Cu-Cy)/Chitosan-Modified Electrode
    Chen, Huan
    Gu, Tingting
    Lv, Longyang
    Chen, Xing
    Lu, Qifeng
    Kotb, Amer
    Chen, Wei
    NANOMATERIALS, 2024, 14 (17)
  • [42] In situ formation of Ag/Au nanorods as a platform to design a non-aggregation colorimetric assay for uric acid detection in biological fluids
    Amjadi, Mohammad
    Hallaj, Tooba
    Nasirloo, Elham
    MICROCHEMICAL JOURNAL, 2020, 154
  • [43] Colorimetric detection of Aflatoxin B1 by using smartphone-assisted microfluidic paper-based analytical devices
    Tang, Xuemei
    Su, Ruiqi
    Luo, Haixi
    Zhao, Ying
    Feng, Lu
    Chen, Jian
    FOOD CONTROL, 2022, 132
  • [44] Highly sensitive determination of uric acid in the presence of major interferents using a conducting polymer film modified electrode
    Revin, S. Brillians
    John, S. Abraham
    BIOELECTROCHEMISTRY, 2012, 88 : 22 - 29
  • [45] Highly sensitive colorimetric detection of ascorbic acid using molecularly imprinted photonic crystal hydrogel sensor
    Sanker, S. S. Sree
    Thomas, Subin
    Jacob, Dhanya P.
    Suniya, V. S.
    Nalini, Savitha
    Madhusoodanan, K. N.
    MICROCHEMICAL JOURNAL, 2024, 206
  • [46] Highly Sensitive Detection of Salmonella typhimurium Using a Colorimetric Paper-Based Analytical Device Coupled with Immunomagnetic Separation
    Srisa-Art, Monpichar
    Boehle, Katherine E.
    Geiss, Brian J.
    Henry, Charles S.
    ANALYTICAL CHEMISTRY, 2018, 90 (01) : 1035 - 1043
  • [47] A New Chitosan-Modified Paper-Based SERS Glucose Sensor with Enhanced Reproducibility, Stability, and Sensitivity for Non-Enzymatic Label-Free Detection
    Akter, Rashida
    Kim, Toeun
    Choi, Jong Seob
    Kim, Hongki
    BIOSENSORS-BASEL, 2025, 15 (03):
  • [48] A thermoresponsive microfluidic system integrating a shape memory polymer-modified textile and a paper-based colorimetric sensor for the detection of glucose in human sweat
    He, Jing
    Xiao, Gang
    Chen, Xiaodie
    Qiao, Yan
    Xu, Dan
    Lu, Zhisong
    RSC ADVANCES, 2019, 9 (41) : 23957 - 23963
  • [49] Highly selective and sensitive colorimetric chemosensor using PVA/chitosan ion-imprinted nanofibers for copper ion detection and removal
    Yousefi-Limaee, Nargess
    Rouhani, Shohre
    Kamandi, Ramtin
    HELIYON, 2024, 10 (15)
  • [50] A novel screen-printed microfluidic paper-based electrochemical device for detection of glucose and uric acid in urine (vol 18, 92, 2016)
    Yao, Yong
    Zhang, Chunsun
    BIOMEDICAL MICRODEVICES, 2022, 24 (03)