Highly sensitive colorimetric detection of glucose and uric acid in biological fluids using chitosan-modified paper microfluidic devices

被引:153
|
作者
Gabriel, Ellen F. M. [1 ]
Garcia, Paulo T. [1 ]
Cardoso, Thiago M. G. [1 ]
Lopes, Flavio M. [2 ]
Martins, Felipe T. [1 ]
Coltro, Wendell K. T. [1 ]
机构
[1] Univ Fed Goias, Inst Quim, BR-74690900 Goiania, Go, Brazil
[2] Univ Fed Goias, Fac Farm, BR-74605170 Goiania, Go, Brazil
关键词
ELECTROCHEMISTRY; NANOPARTICLES; SMARTPHONE; PLATFORMS; SURFACE;
D O I
10.1039/c6an00430j
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This paper describes the modification of microfluidic paper-based analytical devices (mu PADs) with chitosan to improve the analytical performance of colorimetric measurements associated with enzymatic bioassays. Chitosan is a natural biopolymer extensively used to modify biosensing surfaces due to its capability of providing a suitable microenvironment for the direct electron transfer between an enzyme and a reactive surface. This hypothesis was investigated using glucose and uric acid (UA) colorimetric assays as model systems. The best colorimetric sensitivity for glucose and UA was achieved using a chromogenic solution composed of 4-aminoantipyrine and sodium 3,5-dichloro-2-hydroxy-benzenesulfonate (4-AAP/DHBS), which provided a linear response for a concentration range between 0.1 and 1.0 mM. Glucose and UA were successfully determined in artificial serum samples with accuracies between 87 and 114%. The limits of detection (LODs) found for glucose and UA assays were 23 and 37 mu M, respectively. The enhanced analytical performance of chitosan-modified mu PADs allowed the colorimetric detection of glucose in tear samples from four nondiabetic patients. The achieved concentration levels ranged from 130 to 380 mu M. The modified mu PADs offered analytical reliability and accuracy as well as no statistical difference from the values achieved through a reference method. Based on the presented results, the proposed mu PAD can be a powerful alternative tool for non-invasive glucose analysis.
引用
收藏
页码:4749 / 4756
页数:8
相关论文
共 50 条
  • [21] A fast and highly sensitive detection of cholesterol using polymer microfluidic devices and amperometric system
    Ruecha, Nipapan
    Siangproh, Weena
    Chailapakul, Orawon
    TALANTA, 2011, 84 (05) : 1323 - 1328
  • [22] Visual and colorimetric detection of uric acid in human serum and urine using chitosan stabilized gold nanoparticles
    Li, Fan
    He, Tianshuang
    Wu, Sihao
    Peng, Zoujun
    Qiu, Ping
    Tang, Xiaomin
    MICROCHEMICAL JOURNAL, 2021, 164
  • [23] Electrochemical detection of glucose from whole blood using paper-based microfluidic devices
    Noiphung, Julaluk
    Songjaroen, Temsiri
    Dungchai, Wijitar
    Henry, Charles S.
    Chailapakul, Orawon
    Laiwattanapaisal, Wanida
    ANALYTICA CHIMICA ACTA, 2013, 788 : 39 - 45
  • [24] HIGHLY SENSITIVE MEASUREMENT OF MEPINDOLOL IN BIOLOGICAL-FLUIDS USING HPLC AND ELECTROCHEMICAL DETECTION
    MILLERIOUX, L
    NTZANIS, L
    JULIAN, B
    GIRAULT, J
    LEFEBVRE, MA
    MIGNOT, A
    FOURTILLAN, JB
    CHROMATOGRAPHIA, 1987, 24 : 377 - 379
  • [25] Simultaneous colorimetric detection of improvised explosive compounds using microfluidic paper-based analytical devices (μPADs)
    Peters, Kelley L.
    Corbin, Inge
    Kaufman, Lindsay M.
    Zreibe, Kyle
    Blanes, Lucas
    McCord, Bruce R.
    ANALYTICAL METHODS, 2015, 7 (01) : 63 - 70
  • [26] A novel screen-printed microfluidic paper-based electrochemical device for detection of glucose and uric acid in urine
    Yong Yao
    Chunsun Zhang
    Biomedical Microdevices, 2016, 18
  • [27] A paper based microfluidic device for easy detection of uric acid using positively charged gold nanoparticles
    Kumar, Anand
    Hens, Abhiram
    Arun, Ravi Kumar
    Chatterjee, Monosree
    Mahato, Kuldeep
    Layek, Keya
    Chanda, Nripen
    ANALYST, 2015, 140 (06) : 1817 - 1821
  • [28] A novel screen-printed microfluidic paper-based electrochemical device for detection of glucose and uric acid in urine
    Yao, Yong
    Zhang, Chunsun
    BIOMEDICAL MICRODEVICES, 2016, 18 (05)
  • [29] A facile colorimetric method for highly sensitive ascorbic acid detection by using CoOOH nanosheets
    Nie, Qiuyu
    Cai, Qiyong
    Xu, Huihui
    Qiao, Zhun
    Li, Zhaohui
    ANALYTICAL METHODS, 2018, 10 (22) : 2623 - 2628
  • [30] Highly sensitive colorimetric detection of lead using maleic acid functionalized gold nanoparticles
    Ratnarathorn, Nalin
    Chailapakul, Orawon
    Dungchai, Wijitar
    TALANTA, 2015, 132 : 613 - 618