Techniques for Self-Measurement of Blood Pressure: Limitations and Needs for Future Research

被引:20
|
作者
Palatini, Paolo [1 ]
Frick, Gerhard N. [2 ]
机构
[1] Univ Padua, Clin Med 4, I-35128 Padua, Italy
[2] Microlife AG, Widnau, Switzerland
来源
JOURNAL OF CLINICAL HYPERTENSION | 2012年 / 14卷 / 03期
关键词
HYPERTENSION-INTERNATIONAL-PROTOCOL; STANDARD-SIZE BLADDER; EUROPEAN-SOCIETY; WIDE-RANGE; MEASURING DEVICES; CONICAL CUFF; SINGLE CUFF; HOME; RELIABILITY; VALIDATION;
D O I
10.1111/j.1751-7176.2011.00586.x
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
Self blood pressure measurement (SBPM) improves the overall management of hypertension provided it is implemented with methodologic care. This concerns especially the accuracy and technical requirements of blood pressure (BP) measuring devices that should be validated according to internationally accepted protocols. The use of memoryequipped automatic home monitors is strongly recommended because they reduce observer bias, avoid patients' misreporting, and allow fully automatic analysis by software. For current use, simple software should be worked out that allow for analysis of readings in an objective manner. Miscuffing is also a frequent source of measurement error in obese arms when oscillometric devices are used. Modern automatic devices can overcome this problem because of special software algorithms that can provide accurate measurements over a wide range of arm circumferences when coupled with a single cuff of standard dimensions. Troncoconical- shaped cuffs are a key component of this instrumentation because they better fit on large conical arms frequently present in obese individuals. Semi- rigid cuffs should be increasingly used because they ensure that the proper amount of tension is applied without the intervention of the user. Continuous technology improvement of instrumentation for SBPM can be achieved through close cooperation between manufacturers and validation centers. J Clin Hypertens (Greenwich). 2012; 14: 139- 143. (C) 2012 Wiley Periodicals, Inc.
引用
收藏
页码:139 / 143
页数:5
相关论文
共 50 条
  • [1] Self-measurement of blood pressure: strengths and limitations in clinical and research settings
    Platonova, E. V.
    Gorbunov, V. M.
    Shalnova, S. A.
    [J]. CARDIOVASCULAR THERAPY AND PREVENTION, 2009, 8 (06): : 88 - 97
  • [2] Devices for blood pressure self-measurement: Present and future
    Schmidt, W
    [J]. ZEITSCHRIFT FUR KARDIOLOGIE, 1996, 85 : 13 - 19
  • [3] Self-measurement of blood pressure
    Weber, F
    Philipp, T
    [J]. DEUTSCHE MEDIZINISCHE WOCHENSCHRIFT, 1997, 122 (11) : 335 - 338
  • [4] Blood Pressure Self-Measurement
    Wagner, Stefan
    [J]. HYPERTENSION: FROM BASIC RESEARCH TO CLINICAL PRACTICE, VOL 2, 2017, 956 : 97 - 107
  • [5] Blood Pressure self-measurement
    Faure, Sebastien
    Meliani-Pohu, Mary
    Marzellier, Angelique
    Caillemet, Helene
    Leriverend, Helene
    [J]. ACTUALITES PHARMACEUTIQUES, 2013, 52 (522): : 27 - 32
  • [6] Challenges in Blood Pressure Self-Measurement
    Wagner, Stefan
    Toftegaard, Thomas Skjodeberg
    Bertelsen, Olav W.
    [J]. INTERNATIONAL JOURNAL OF TELEMEDICINE AND APPLICATIONS, 2012, 2012
  • [7] SELF-MEASUREMENT OF BLOOD-PRESSURE
    WEBER, F
    ANLAUF, M
    [J]. MUNCHENER MEDIZINISCHE WOCHENSCHRIFT, 1983, 125 (45): : 1017 - 1021
  • [8] SELF-MEASUREMENT OF BLOOD-PRESSURE
    不详
    [J]. LANCET, 1988, 2 (8607): : 377 - 378
  • [9] SELF-MEASUREMENT OF BLOOD-PRESSURE
    不详
    [J]. BULLETIN OF THE WORLD HEALTH ORGANIZATION, 1988, 66 (02) : 155 - 159
  • [10] SELF-MEASUREMENT OF BLOOD-PRESSURE
    KOENIGSBERGER, CW