Techniques for Self-Measurement of Blood Pressure: Limitations and Needs for Future Research

被引:21
|
作者
Palatini, Paolo [1 ]
Frick, Gerhard N. [2 ]
机构
[1] Univ Padua, Clin Med 4, I-35128 Padua, Italy
[2] Microlife AG, Widnau, Switzerland
来源
JOURNAL OF CLINICAL HYPERTENSION | 2012年 / 14卷 / 03期
关键词
HYPERTENSION-INTERNATIONAL-PROTOCOL; STANDARD-SIZE BLADDER; EUROPEAN-SOCIETY; WIDE-RANGE; MEASURING DEVICES; CONICAL CUFF; SINGLE CUFF; HOME; RELIABILITY; VALIDATION;
D O I
10.1111/j.1751-7176.2011.00586.x
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
Self blood pressure measurement (SBPM) improves the overall management of hypertension provided it is implemented with methodologic care. This concerns especially the accuracy and technical requirements of blood pressure (BP) measuring devices that should be validated according to internationally accepted protocols. The use of memoryequipped automatic home monitors is strongly recommended because they reduce observer bias, avoid patients' misreporting, and allow fully automatic analysis by software. For current use, simple software should be worked out that allow for analysis of readings in an objective manner. Miscuffing is also a frequent source of measurement error in obese arms when oscillometric devices are used. Modern automatic devices can overcome this problem because of special software algorithms that can provide accurate measurements over a wide range of arm circumferences when coupled with a single cuff of standard dimensions. Troncoconical- shaped cuffs are a key component of this instrumentation because they better fit on large conical arms frequently present in obese individuals. Semi- rigid cuffs should be increasingly used because they ensure that the proper amount of tension is applied without the intervention of the user. Continuous technology improvement of instrumentation for SBPM can be achieved through close cooperation between manufacturers and validation centers. J Clin Hypertens (Greenwich). 2012; 14: 139- 143. (C) 2012 Wiley Periodicals, Inc.
引用
收藏
页码:139 / 143
页数:5
相关论文
共 50 条
  • [31] Telemonitoring of blood pressure self-measurement (BPSM) in the OLMETEL study
    Uen, S
    Ewald, S
    Kaufmann, S
    Vor Dem Esche, J
    Mengden, T
    JOURNAL OF HYPERTENSION, 2004, 22 : S26 - S26
  • [32] Determination of normality limit of blood pressure by home self-measurement
    Cia Huarte, A.
    Fanlo Mateo, P.
    Uranga Aguirre, J.
    Ezcurdia Irurzun, E.
    Berrade Marticorena, F.
    Tiberio Lopez, G.
    REVISTA CLINICA ESPANOLA, 2006, 206 (07): : 305 - 313
  • [33] Use of the median for the evaluation of blood pressure self-measurement (BPSM)
    Lijarcio, Manuel Amaro
    Yuste, Enrique Angulo
    Senso, Adolfo Arias
    Aparicio, Javier Blanco
    de la Pena Ruiz, Jose Antonio
    Garcia, Manuel Diez
    Tobal, Francisca Galindo
    Martinez Llarena, Maria Luisa
    Garcia, Candido Mena
    Cano, Francisco Parralejo
    Perez Castan, Jose F.
    Robles Perez-Monteoliva, Nicolas R.
    Santos, Natividad Sanchez
    EUROPEAN JOURNAL OF INTERNAL MEDICINE, 2007, 18 (01) : 31 - 34
  • [34] ASSESSING THE USEFULNESS OF SELF-MEASUREMENT OF BLOOD PRESSURE IN PATIENTS IN CONTROLLING BLOOD PRESSURE IN HYPERTENSIVES
    Patil, Vishal
    Patil, Mansi
    JOURNAL OF HYPERTENSION, 2021, 39 : E120 - E121
  • [35] Device for the self-measurement of blood pressure that can monitor blood pressure during sleep
    Chonan, K
    Kikuya, M
    Araki, T
    Fujiwara, T
    Suzuki, M
    Michimata, M
    Hashimoto, J
    Ohkubo, T
    Hozawa, A
    Yamamoto, N
    Miyawaki, Y
    Matsubara, M
    Imai, Y
    BLOOD PRESSURE MONITORING, 2001, 6 (04) : 203 - 205
  • [36] Self-measurement of blood pressure in clinical trials and therapeutic applications
    Denolle, T
    Waeber, B
    Kjeldsen, S
    Parati, G
    Wilson, M
    Asmar, R
    BLOOD PRESSURE MONITORING, 2000, 5 (02) : 145 - 149
  • [37] Reliable Blood Pressure Self-measurement in the Obstetric Waiting Room
    Wagner, S.
    Kamper, C. H.
    Rasmussen, N. H.
    Ahrendt, P.
    Toftegaard, T. S.
    Bertelsen, O. W.
    METHODS OF INFORMATION IN MEDICINE, 2014, 53 (03) : 225 - 234
  • [38] BLOOD-PRESSURE SELF-MEASUREMENT IN NORMOTENSIVE AND HYPERTENSIVE PATIENTS
    BATTIG, B
    STEINER, A
    JECK, T
    VETTER, W
    JOURNAL OF HYPERTENSION, 1989, 7 : S59 - S63
  • [39] EFFECT OF SELF-MEASUREMENT OF BLOOD PRESSURE ON HEMODYNAMICS - THE ANSIA STUDY
    Gazzola, K.
    Honingh, M.
    Truijen, J.
    Van den Born, B. J. H.
    JOURNAL OF HYPERTENSION, 2017, 35 : E225 - E225
  • [40] Glucose Self-measurement - technical Possibilities and Limitations
    Forst, T.
    Zijlstra, E.
    DIABETOLOGIE UND STOFFWECHSEL, 2016, 11 (06) : R51 - R57