Complications After Heart Transplantation According to the Type of Pretransplant Circulatory/Ventricular Support

被引:1
|
作者
Lopez-Vilella, Raquel [1 ,2 ]
Sanchez-Lazaro, Ignacio [1 ,2 ,3 ]
Pajares Moncho, Azucena [4 ]
Perez Esteban, Francisca [5 ]
Perez Guillen, Manuel [6 ]
Zarragoikoetxea Jauregui, Iratxe [4 ]
Gimeno Costa, Ricardo [5 ]
Martinez Dolz, Luis [2 ,3 ]
Torregrosa Puerta, Salvador [6 ]
Almenar Bonet, Luis [1 ,2 ,3 ,7 ]
机构
[1] La Fe Univ & Polytech Hosp, Heart Failure & Transplant Unit, Valencia, Spain
[2] La Fe Univ & Polytech Hosp, Dept Cardiol, Valencia, Spain
[3] Inst Salud Carlos III, Ctr Invest Biomed Red Enfermedades Cardiovasc CIB, Madrid, Spain
[4] La Fe Univ & Polytech Hosp, Dept Anesthesiol & Resuscitat, Valencia, Spain
[5] La Fe Univ & Polytech Hosp, Dept Intens Med, Valencia, Spain
[6] La Fe Univ & Polytech Hosp, Dept Cardiovasc Surg, Valencia, Spain
[7] Univ Valencia, Valencia, Spain
关键词
CARDIOGENIC-SHOCK;
D O I
10.1016/j.transproceed.2021.08.040
中图分类号
R392 [医学免疫学]; Q939.91 [免疫学];
学科分类号
100102 ;
摘要
Background. The purpose of the study was to analyze postcardiac transplant complications in patients who received transplants with short-term mechanical ventricular assist devices and to compare complications according to the type of device. Methods. Ambispective and consecutive study of urgent heart transplants from 2015 to 2019. Pediatric transplants, retransplants, and combined transplants were excluded. A total of 45 patients were analyzed in 4 groups: (1) venoarterial extracorporeal membrane oxygenation (ECMO) implanted <10 days before heart transplant (HTx) (n = 17); (2) ECMO implanted for more than 10 days (n = 8); (3) Levitronix Centrimag implanted in INTERMACS 2 to 3 patients (n = 13); and (4) Levitronix Centrimag implanted in INTERMACS 2 patients (n = 7). ECMO assistance was in INTERMACS 2 and severe right ventricular dysfunction. Levitronix Centrimag was implanted in patients with preserved right ventricular function. Results. Primary graft failure associated with the need for ECMO was more frequent in patients with ECMO than with Levitronix (P < .05). When comparing the 2 groups with ECMO, an implant more than 10 days before HTx was associated, after transplant, with a longer stay in the critical care unit (P = .02), higher mortality (P = .03), and an increase in complications in general. When comparing the 2 groups with Levitronix, all the parameters studied were much better when the Levitronix was implanted in IN IERMACS 2-3 (P < .05). On the other hand, all cases of deep vein thrombosis and pulmonary thromboembolism occurred in patients who were assisted with ECMO. Conclusions. HTx with mechanical assist devices is associated with significant complications. ECMO produces more complications than the Levitronix Centrimag, although they are related to the days of implantation. The best group are patients implanted with a Levitronix in INTERMACS 2-3.
引用
收藏
页码:2739 / 2742
页数:4
相关论文
共 50 条
  • [41] Heart transplantation in children after mechanical circulatory support with pulsatile pneumatic assist device
    Stiller, B
    Hetzer, R
    Weng, YG
    Hummel, M
    Hennig, E
    Nagdyman, N
    Ewert, P
    Lehmkuhl, H
    Lange, PE
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2003, 22 (11): : 1201 - 1208
  • [42] BRIDGING TO HEART-TRANSPLANTATION WITH CIRCULATORY SUPPORT DEVICES
    PENNINGTON, DG
    MCBRIDE, LR
    KANTER, KR
    MILLER, LW
    RUZEVICH, SA
    NAUNHEIM, K
    SWARTZ, MT
    TERMUHLEN, D
    JOURNAL OF HEART TRANSPLANTATION, 1989, 8 (02): : 116 - 123
  • [43] Durable mechanical circulatory support as bridge to heart transplantation
    Badiwala, Mitesh
    Dvirnik, Nazari
    Rao, Vivek
    CURRENT OPINION IN ORGAN TRANSPLANTATION, 2022, 27 (05) : 488 - 494
  • [44] Sex, Temporary Mechanical Circulatory Support, and Heart Transplantation
    Enriquez-Vazquez, Daniel
    Barge-Caballero, Eduardo
    Gonzalez-Vilchez, Francisco
    Almenar-Bonet, Luis
    Carmena, Maria Dolores Garcia-Cosio
    Gonzalez-Costello, Jose
    Gomez-Bueno, Manuel
    Castel-Lavilla, Maria Angeles
    Diaz-Molina, Beatriz
    Martinez-Selles, Manuel
    Mirabet-Perez, Sonia
    De la Fuente-Galan, Luis
    Hervas-Sotomayor, Daniela
    Rangel-Sousa, Diego
    Garrido-Bravo, Iris P.
    Blasco-Peiro, Teresa
    Juan-Aracil, Gregorio Rabago
    Muniz, Javier
    Crespo-Leiro, Maria G.
    JACC-HEART FAILURE, 2023, 11 (12) : 1763 - 1766
  • [45] Successful Pediatric Orthotopic Heart Transplantation After Three Runs of Mechanical Circulatory Support
    Filippelli, Sergio
    Perri, Gianluigi
    Kirk, Richard
    Griselli, Massimo
    Hasan, Asif
    ANNALS OF THORACIC SURGERY, 2013, 95 (06): : 2176 - 2178
  • [46] The Effect of Preoperative use of Mechanical Circulatory Support on Survival After Heart Transplantation in Finland
    Kiss, J.
    Nykanen, A.
    Stark, C.
    Lemstrom, K.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2018, 37 (04): : S435 - S435
  • [47] Psychosocial factors and quality-of-life after heart transplantation and mechanical circulatory support
    Rosenberger, Emily M.
    Fox, Kristen R.
    DiMartini, Andrea F.
    Dew, Mary Amanda
    CURRENT OPINION IN ORGAN TRANSPLANTATION, 2012, 17 (05) : 558 - 563
  • [48] Utilization and Outcomes of Temporary Mechanical Circulatory Support for Graft Dysfunction After Heart Transplantation
    Phan, Kevin
    Luc, Jessica G. Y.
    Xu, Joshua
    Maltais, Simon
    Stulak, John M.
    Yan, Tristan D.
    Tchantchaleishvili, Vakhtang
    ASAIO JOURNAL, 2017, 63 (06) : 695 - 703
  • [49] Circulatory assistance while waiting for heart transplantation -: Outcome of heart transplantation after mechanical circulatory assistance
    Kirsch, M
    Houël, R
    Vermès, E
    Thébert, D
    Loisance, D
    PRESSE MEDICALE, 2000, 29 (34): : 1910 - 1912
  • [50] Donation After Circulatory Death for Heart Transplantation
    Cho, P. D.
    Kim, S. T.
    Nsair, A.
    Biniwale, R.
    Ardehali, A.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2024, 43 (04): : S125 - S125