Complications After Heart Transplantation According to the Type of Pretransplant Circulatory/Ventricular Support

被引:1
|
作者
Lopez-Vilella, Raquel [1 ,2 ]
Sanchez-Lazaro, Ignacio [1 ,2 ,3 ]
Pajares Moncho, Azucena [4 ]
Perez Esteban, Francisca [5 ]
Perez Guillen, Manuel [6 ]
Zarragoikoetxea Jauregui, Iratxe [4 ]
Gimeno Costa, Ricardo [5 ]
Martinez Dolz, Luis [2 ,3 ]
Torregrosa Puerta, Salvador [6 ]
Almenar Bonet, Luis [1 ,2 ,3 ,7 ]
机构
[1] La Fe Univ & Polytech Hosp, Heart Failure & Transplant Unit, Valencia, Spain
[2] La Fe Univ & Polytech Hosp, Dept Cardiol, Valencia, Spain
[3] Inst Salud Carlos III, Ctr Invest Biomed Red Enfermedades Cardiovasc CIB, Madrid, Spain
[4] La Fe Univ & Polytech Hosp, Dept Anesthesiol & Resuscitat, Valencia, Spain
[5] La Fe Univ & Polytech Hosp, Dept Intens Med, Valencia, Spain
[6] La Fe Univ & Polytech Hosp, Dept Cardiovasc Surg, Valencia, Spain
[7] Univ Valencia, Valencia, Spain
关键词
CARDIOGENIC-SHOCK;
D O I
10.1016/j.transproceed.2021.08.040
中图分类号
R392 [医学免疫学]; Q939.91 [免疫学];
学科分类号
100102 ;
摘要
Background. The purpose of the study was to analyze postcardiac transplant complications in patients who received transplants with short-term mechanical ventricular assist devices and to compare complications according to the type of device. Methods. Ambispective and consecutive study of urgent heart transplants from 2015 to 2019. Pediatric transplants, retransplants, and combined transplants were excluded. A total of 45 patients were analyzed in 4 groups: (1) venoarterial extracorporeal membrane oxygenation (ECMO) implanted <10 days before heart transplant (HTx) (n = 17); (2) ECMO implanted for more than 10 days (n = 8); (3) Levitronix Centrimag implanted in INTERMACS 2 to 3 patients (n = 13); and (4) Levitronix Centrimag implanted in INTERMACS 2 patients (n = 7). ECMO assistance was in INTERMACS 2 and severe right ventricular dysfunction. Levitronix Centrimag was implanted in patients with preserved right ventricular function. Results. Primary graft failure associated with the need for ECMO was more frequent in patients with ECMO than with Levitronix (P < .05). When comparing the 2 groups with ECMO, an implant more than 10 days before HTx was associated, after transplant, with a longer stay in the critical care unit (P = .02), higher mortality (P = .03), and an increase in complications in general. When comparing the 2 groups with Levitronix, all the parameters studied were much better when the Levitronix was implanted in IN IERMACS 2-3 (P < .05). On the other hand, all cases of deep vein thrombosis and pulmonary thromboembolism occurred in patients who were assisted with ECMO. Conclusions. HTx with mechanical assist devices is associated with significant complications. ECMO produces more complications than the Levitronix Centrimag, although they are related to the days of implantation. The best group are patients implanted with a Levitronix in INTERMACS 2-3.
引用
收藏
页码:2739 / 2742
页数:4
相关论文
共 50 条
  • [31] Transplantation of the Heart After Circulatory Death
    Cooper, D. K. C.
    AMERICAN JOURNAL OF TRANSPLANTATION, 2016, 16 (10) : 3063 - 3063
  • [32] Influence of durable mechanical circulatory support and allosensitization on mortality after heart transplantation
    Chiu, Peter
    Schaffer, Justin M.
    Oyer, Philip E.
    Pham, Michael
    Banerjee, Dipanjan
    Woo, Y. Joseph
    Ha, Richard
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2016, 35 (06): : 731 - 742
  • [33] HEART-TRANSPLANTATION AFTER MECHANICAL CIRCULATORY SUPPORT - 4 YEARS EXPERIENCE
    BIROVLJEV, S
    RADOVANCEVIC, B
    BURNETT, CM
    VEGA, JD
    BENNINK, G
    LONQUIST, JL
    DUNCAN, JM
    FRAZIER, OH
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 1992, 11 (02): : 240 - 245
  • [34] Impact of pretransplant antibodies on outcomes after heart transplantation
    Nunoda, Shinichi
    CURRENT OPINION IN ORGAN TRANSPLANTATION, 2019, 24 (03) : 220 - 226
  • [35] Impact of Support Period and Type of Ventricular Assist Device on Patient Survival After Heart Transplantation: Japanese Heart Transplantation Registry 2016
    Fukushima, N.
    Ono, M.
    Saiki, Y.
    Sawa, Y.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2017, 36 (04): : S437 - S437
  • [36] Influence of the type of circulatory/ventricular assistance in the primary graft failure and heart transplantation mortality
    Raquel Lopez Vilella, R.
    Sanchez Lazaro, I.
    Fuset Cabanes, M. P.
    Pajares Moncho, A.
    Donate Bertolin, L.
    Gimeno Costa, R.
    Moreno Puigdollers, I.
    Zarragoikoetxea Jauregui, I.
    Martinez Dolz, L.
    Castellanos Ortega, A.
    Vicente Guillen, R.
    Torregrosa Puerta, S.
    Almenar Bonet, L.
    EUROPEAN JOURNAL OF HEART FAILURE, 2018, 20 : 82 - 82
  • [37] Impact of type of mechanical circulatory support before transplant on postorthotopic heart transplantation infections
    Trottier, Caitlin A.
    Martino, Audrey
    Short, Meghan I.
    Rodday, Angie Mae
    Strand, Andrew M.
    Kiernan, Michael S.
    Vest, Amanda R.
    Snydman, David R.
    Chow, Jennifer K.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2025, 44 (02): : 215 - 224
  • [38] Pretransplant Right Ventricular Dysfunction Is Associated With Increased Mortality After Heart Transplantation: A Hard Inheritance to Overcome
    Bellettini, Matteo
    Frea, Simone
    Pidello, Stefano
    Boffini, Massimo
    Boretto, Paolo
    Gallone, Guglielmo
    Bongiovanni, Federica
    Masetti, Marco
    Sabatino, Mario
    Raineri, Claudia
    Pacini, Davide
    Suarez, Sofia Martin
    Loforte, Antonio
    Rinaldi, Mauro
    Potena, Luciano
    De Ferrari, Gaetano M.
    JOURNAL OF CARDIAC FAILURE, 2022, 28 (02) : 259 - 269
  • [39] Circulatory Support as a Bridge to Pediatric Heart Transplantation Reply
    Caneo, Luiz Fernando
    Miana, Leonardo A.
    Jatene, Marcelo B.
    ARQUIVOS BRASILEIROS DE CARDIOLOGIA, 2016, 106 (04) : 351 - 351
  • [40] Mechanical circulatory support: not only a bridge to heart transplantation
    Sobieszczanska-Malek, Malgorzata
    Zielinski, Tomasz
    Korewicki, Jerzy
    KARDIOLOGIA POLSKA, 2012, 70 (11) : 1182 - 1186