Beam position monitor system for PEP-II

被引:0
|
作者
Smith, SR [1 ]
Aiello, GR [1 ]
Hendrickson, LJ [1 ]
Johnson, RG [1 ]
Mills, MR [1 ]
Olsen, JJ [1 ]
机构
[1] Stanford Linear Accelerator Ctr, Stanford, CA 94309 USA
关键词
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
We describe the beam position monitor system built for PEP-II, the B-factory at SLAG. The system reports beam position for bunches of between 5 x 10(8) and 8 x 10(10) electron charges, either singly or as continuous streams of bunches every 4.2 ns. Resolution at full charge is to be better than 10 microns in a single turn. Higher resolution is available via on-board multi-turn averaging. The position signal is processed in a 20 MHz bandwidth around 952 MHz. This bandwidth, rather broader than that typical of RF position monitors, allows good resolution for low charge single bunches. Additional novel features include stringent control of return losses in order to minimize cross-talk between nearby bunches which may contain very different charges. The digitizing electronics is multiplexed between the two PER-Il storage rings. Design, construction, and installation experience, as well as first results with beam are presented.
引用
收藏
页码:2122 / 2124
页数:3
相关论文
共 50 条
  • [11] The PEP-II abort kicker system
    de Lamare, J
    Donaldson, A
    Kulikov, A
    Lipari, J
    PROCEEDINGS OF THE 1997 PARTICLE ACCELERATOR CONFERENCE, VOLS 1-3: PLENARY AND SPECIAL SESSIONS ACCELERATORS AND STORAGE RINGS - BEAM DYNAMICS, INSTRUMENTATION, AND CONTROLS, 1998, : 1316 - 1318
  • [12] PEP-II abort kicker system
    de Lamare, J.
    Donaldson, A.
    Kulikov, A.
    Lipari, L.
    Proceedings of the IEEE Particle Accelerator Conference, 1998, 1 : 1316 - 1318
  • [13] A transverse beam instability in the PEP-II HER induced by discharges in the vacuum system
    Wienands, U.
    DeBarger, S.
    Colocho, W.
    Decker, F. -J.
    Ecklund, S.
    Fisher, A.
    Fox, J.
    Kulikov, A.
    Novokhatski, A.
    Stanek, M.
    Sullivan, M. K.
    Wittmer, W.
    Wright, D.
    Yocky, G.
    2007 IEEE PARTICLE ACCELERATOR CONFERENCE, VOLS 1-11, 2007, : 3032 - 3034
  • [14] FINAL-FOCUS MAGNET SYSTEM FOR PEP-II
    TAYLOR, CE
    CASPI, S
    SAHO, N
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 1995, 5 (02) : 878 - 881
  • [15] Tune feedback in PEP-II
    Fisher, AS
    Laznovsky, M
    Allison, SA
    Chestnut, RP
    Petree, M
    2003 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-5, 2004, : 1557 - 1560
  • [16] PEP-II hardware reliability
    Allen, CW
    Colocho, W
    Erickson, R
    Stanek, M
    2004 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-7, 2004, : 1788 - 1792
  • [17] Status of PEP-II and BABAR
    Lista, L
    NUCLEAR PHYSICS B-PROCEEDINGS SUPPLEMENTS, 1998, 66 : 541 - 544
  • [18] Status of PEP-II and BaBar
    Dorfan, J
    INTERNATIONAL JOURNAL OF MODERN PHYSICS A, 2000, 15 : 22 - 34
  • [19] PEP-II operations report
    Zisman, MS
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2001, 462 (1-2): : 132 - 138
  • [20] Instrumentation and diagnostics for PEP-II
    Fisher, AS
    BEAM INSTRUMENTATION WORKSHOP, 1998, 451 : 95 - 109