Effect of Rotational Modes on Torque/Force Generation and Canal Centering Ability during Rotary Root Canal Instrumentation with Differently Heat-Treated Nickel-Titanium Instruments

被引:0
|
作者
Omori, Satoshi [1 ]
Ebihara, Arata [1 ]
Hirano, Keiko [1 ]
Kasuga, Yuka [1 ]
Unno, Hayate [1 ]
Nakatsukasa, Taro [1 ]
Kimura, Shunsuke [1 ]
Maki, Keiichiro [1 ]
Hanawa, Takao [2 ]
Okiji, Takashi [1 ]
机构
[1] Tokyo Med & Dent Univ TMDU, Grad Sch Med & Dent Sci, Dept Pulp Biol & Endodont, Div Oral Hlth Sci,Bunkyo Ku, 1-5-45 Yushima, Tokyo 1138549, Japan
[2] Tokyo Med & Dent Univ TMDU, Inst Biomat & Bioengn, Dept Metall Biomat, Chiyoda Ku, 2-3-10 Kanda Surugadai, Tokyo 1010062, Japan
关键词
canal centering ability; heat treatment; nickel-titanium rotary instruments; optimum torque reverse motion; reciprocation; screw-in force; torque; CYCLIC FATIGUE; SHAPING ABILITY; PROTAPER GOLD; ENDODONTIC INSTRUMENTS; MECHANICAL-PROPERTIES; VERTICAL FORCE; RESISTANCE; UNIVERSAL; FILES; RECIPROCATION;
D O I
10.3390/ma15196850
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
This study aimed to evaluate how various rotational modes influence the torque/force production and shaping ability of ProTaper Universal (PTU; non-heat-treated) and ProTaper Gold (PTG; heat-treated) nickel-titanium instruments. J-shaped resin canals were instrumented with PTU or PTG using an automated instrumentation device operated with reciprocating rotation [150 degrees clockwise and 30 degrees counterclockwise (R150/30) or 240 degrees clockwise and 120 degrees counterclockwise (R240/120)], optimum torque reverse motion (OTR), or continuous rotation (CR) (n = 10 each). Maximum force and torque were recorded, and canal centering ratios were calculated. Statistical analysis was performed with two-way ANOVA and a Bonferroni test (alpha = 0.05). The results were considered with reference to previous studies on the microstructure of the instruments. The upward force generated by R240/120 and OTR was smaller than that generated by R150/30 and CR in PTG (p < 0.05). The clockwise torque produced by OTR was lower than that produced by R150/30 in PTU and R240/120 and CR in PTG (p < 0.05). R240/120 and OTR induced less canal deviation compared to CR in PTU at 0 mm from the apex (p < 0.05). In conclusion, R240/120 and OTR reduced the screw-in force in PTG and improved the canal centering ability in PTU, which may be associated with the heat treatment-induced microstructural difference of the two instruments.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] Effect of Different Downward Loads on Canal Centering Ability, Vertical Force, and Torque Generation during Nickel-Titanium Rotary Instrumentation
    Maki, Keiichiro
    Ebihara, Arata
    Unno, Hayate
    Omori, Satoshi
    Nakatsukasa, Taro
    Kimura, Shunsuke
    Okiji, Takashi
    MATERIALS, 2022, 15 (08)
  • [2] Effect of Different Speeds of Up-and-down Motion on Canal Centering Ability and Vertical Force and Torque Generation of Nickel-titanium Rotary Instruments
    Maki, Keiichiro
    Ebihara, Arata
    Kimura, Shunsuke
    Nishijo, Miki
    Tokita, Daisuke
    Okiji, Takashi
    JOURNAL OF ENDODONTICS, 2019, 45 (01) : 68 - 72
  • [3] Torque during canal instrumentation using rotary nickel-titanium files
    Sattapan, B
    Palamara, JEA
    Messer, HH
    JOURNAL OF ENDODONTICS, 2000, 26 (03) : 156 - 160
  • [4] Analysis of Torque and Force Induced by Rotary Nickel-Titanium Instruments during Root Canal Preparation: A Systematic Review
    Thu, Myint
    Ebihara, Arata
    Adel, Sherif
    Okiji, Takashi
    APPLIED SCIENCES-BASEL, 2021, 11 (07):
  • [5] Shaping Ability and Debris Extrusion of New Rotary Nickel-Titanium Root Canal Instruments
    Buerklein, Sebastian
    Donnermeyer, David
    Hentschel, Tim Julian
    Schaefer, Edgar
    MATERIALS, 2021, 14 (05) : 1 - 8
  • [6] Dynamic Torque and Vertical Force Analysis during Nickel-titanium Rotary Root Canal Preparation with Different Modes of Reciprocal Rotation
    Tokita, Daisuke
    Ebihara, Arata
    Nishijo, Miki
    Miyara, Kana
    Okiji, Takashi
    JOURNAL OF ENDODONTICS, 2017, 43 (10) : 1706 - 1710
  • [7] Effect of nickel-titanium alloys on root canal preparation and on mechanical properties of rotary instruments
    Vivan, Rodrigo Ricci
    Sanches Marques Costa, Vanessa Abreu
    Conti, Leticia Citelli
    Duque, Jussaro Alves
    Bramante, Clovis Monteiro
    So, Marcus Vinicius Reis
    Alcalde, Murilo Priori
    Hungaro Duarte, Marco Antonio
    BRAZILIAN ORAL RESEARCH, 2022, 36
  • [8] Impact of Radial Lands on the Reduction of Torque/Force Generation of a Heat-Treated Nickel-Titanium Rotary Instrument
    Nakatsukasa, Taro
    Ebihara, Arata
    Kyaw, Moe Sandar
    Omori, Satoshi
    Unno, Hayate
    Kimura, Shunsuke
    Maki, Keiichiro
    Okiji, Takashi
    APPLIED SCIENCES-BASEL, 2022, 12 (05):
  • [9] Micro-Computed Tomographic Evaluation of Canal Transportation and Centering Ability of 4 Heat-Treated Nickel-Titanium Systems
    Razcha, Christina
    Zacharopoulos, Athanasios
    Anestis, Dimitris
    Mikrogeorgis, Georgios
    Zacharakis, Giannis
    Lyroudia, Kleoniki
    JOURNAL OF ENDODONTICS, 2020, 46 (05) : 675 - 681
  • [10] Conditioning of root canal anatomy on static and dynamics of nickel-titanium rotary instruments
    Di Giuseppe, Italo
    Di Giuseppe, Davide
    Malagnino, Vito Antonio
    Silla, Enrico Paolo
    Somma, Francesco
    GIORNALE ITALIANO DI ENDODONZIA, 2015, 29 (02): : 58 - 64