Monte Carlo simulations of neutron spectral fluence, radiation weighting factor and ambient dose equivalent for a passively scattered proton therapy unit

被引:60
|
作者
Zheng, Yuanshui [1 ]
Fontenot, Jonas [1 ,2 ]
Taddei, Phil [1 ]
Mirkovic, Dragan [1 ]
Newhauser, Wayne [1 ,2 ]
机构
[1] Univ Texas MD Anderson Canc Ctr, Dept Radiat Phys, Unit 94, Houston, TX 77030 USA
[2] Univ Texas Houston, Grad Sch Biomed Sci, Houston, TX 77030 USA
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2008年 / 53卷 / 01期
关键词
D O I
10.1088/0031-9155/53/1/013
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Stray neutron exposures pose a potential risk for the development of secondary cancer in patients receiving proton therapy. However, the behavior of the ambient dose equivalent is not fully understood, including dependences on neutron spectral fluence, radiation weighting factor and proton treatment beam characteristics. The objective of this work, therefore, was to estimate neutron exposures resulting from the use of a passively scattered proton treatment unit. In particular, we studied the characteristics of the neutron spectral fluence, radiation weighting factor and ambient dose equivalent with Monte Carlo simulations. The neutron spectral fluence contained two pronounced peaks, one a low-energy peak with a mode around 1 MeV and one a high-energy peak that ranged from about 10 MeV up to the proton energy. The mean radiation weighting factors varied only slightly, from 8.8 to 10.3, with proton energy and location for a closed-aperture configuration. For unmodulated proton beams stopped in a closed aperture, the ambient dose equivalent from neutrons per therapeutic absorbed dose (H*(10)/D) calculated free-in-air ranged from about 0.3 mSv/Gy for a small scattered field of 100 MeV proton energy to 19 mSv/Gy for a large scattered field of 250 MeV proton energy, revealing strong dependences on proton energy and field size. Comparisons of in-air calculations with in-phantom calculations indicated that the in-air method yielded a conservative estimation of stray neutron radiation exposure for a prostate cancer patient.
引用
收藏
页码:187 / 201
页数:15
相关论文
共 50 条
  • [1] Monte Carlo Simulations of Neutron Ambient Dose Equivalent in a Novel Proton Therapy Facility Design
    Titt, Uwe
    Pera, Enzo
    Gillin, Michael T.
    [J]. INTERNATIONAL JOURNAL OF PARTICLE THERAPY, 2020, 6 (04) : 29 - 37
  • [2] Monte Carlo simulation of the neutron spectral fluence and dose equivalent for use in shielding a proton therapy vault
    Zheng, Yuanshui
    Newhauser, Wayne
    Klein, Eric
    Low, Daniel
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2009, 54 (22): : 6943 - 6957
  • [3] Monte Carlo Study of Neutron Dose Equivalent for a Compact Proton Therapy Unit
    Zheng, Y.
    Klein, E.
    Chen, K.
    Liu, Y.
    [J]. MEDICAL PHYSICS, 2010, 37 (06)
  • [4] A Monte Carlo based analytic model of the in-room neutron ambient dose equivalent for a Mevion gantry-mounted passively scattered proton system
    Baradaran-Ghahfarokhi, Milad
    Reynoso, Francisco
    Darafsheh, Arash
    Sun, Baozhou
    Prusator, Michael T.
    Mutic, Sasa
    Zhao, Tianyu
    [J]. JOURNAL OF RADIOLOGICAL PROTECTION, 2020, 40 (04) : 980 - 996
  • [5] Angular Distribution of Neutron Fluence and Its Effect On Shielding for a Passively-Scattered Proton Therapy Unit
    Zheng, Y.
    Newhauser, W.
    Klein, E.
    Low, D.
    [J]. MEDICAL PHYSICS, 2008, 35 (06)
  • [6] A Monte Carlo-Based Analytic Model of Neutron Dose Equivalent for a Mevion Gantry-Mounted Passively Scattered Proton System
    BaradaranGhahfarokhi, M.
    Reynoso, F.
    Sun, B.
    Darafsheh, A.
    Prusator, M.
    Mutic, S.
    Zhao, T.
    [J]. MEDICAL PHYSICS, 2020, 47 (06) : E682 - E682
  • [7] Monte Carlo simulations of stray neutron radiation exposures in proton therapy
    Zheng, Yuanshui
    Newhauser, Wayne
    Fontenot, Jonas
    Koch, Nicholas
    Mohan, Radhe
    [J]. JOURNAL OF NUCLEAR MATERIALS, 2007, 361 (2-3) : 289 - 297
  • [8] Monte Carlo and analytical model predictions of leakage neutron exposures from passively scattered proton therapy
    Perez-Andujar, Angelica
    Zhang, Rui
    Newhauser, Wayne
    [J]. MEDICAL PHYSICS, 2013, 40 (12)
  • [9] Monte Carlo study of neutron dose equivalent during passive scattering proton therapy
    Zheng, Yuanshui
    Newhauser, Wayne
    Fontenot, Jonas
    Taddei, Phil
    Mohan, Radhe
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2007, 52 (15): : 4481 - 4496
  • [10] A Monte Carlo-based analytic model of neutron dose equivalent for a mevion gantry-mounted passively scattered proton system for craniospinal irradiation
    Baradaran-Ghahfarokhi, Milad
    Reynoso, Francisco
    Sun, Baozhou
    Darafsheh, Arash
    Prusator, Michael T.
    Mutic, Sasa
    Zhao, Tianyu
    [J]. MEDICAL PHYSICS, 2020, 47 (09) : 4509 - 4521