Role of continuous glucose monitoring in the management of glycogen storage disorders

被引:26
|
作者
Herbert, Mrudu [1 ]
Pendyal, Surekha [1 ]
Rairikar, Mugdha [1 ]
Halaby, Carine [1 ]
Benjamin, Robert W. [2 ]
Kishnani, Priya S. [1 ]
机构
[1] Duke Univ, Med Ctr, Dept Pediat, Div Med Genet, 905 South LaSalle St,GSRB1, Durham, NC 27710 USA
[2] Duke Univ, Sch Med, Dept Pediat, Div Endocrinol, Durham, NC USA
关键词
DIABETES-MELLITUS; IMPAIRED AWARENESS; GLYCEMIC CONTROL; HYPOGLYCEMIA; ADULTS; FREQUENCY; SECONDARY; CHILDREN; QUALITY; LIFE;
D O I
10.1007/s10545-018-0200-5
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Management of liver glycogen storage diseases (GSDs) primarily involves maintaining normoglycemia through dietary modifications and regular glucose monitoring. Self-monitoring of blood glucose is typically done 3-6 times per day, and may not sufficiently capture periods of asymptomatic hypoglycemia, particularly during sleep. Continuous glucose monitoring systems (CGMS) provide 24-h continuous glucose data and have been used effectively in diabetes mellitus to monitor metabolic control and optimize treatment. This is a relatively new approach in GSDs with only a handful of studies exploring this modality. In this study we used Dexcom CGMS to study the glycemic profile of 14 pediatric and six adult patients with GSD I, III, and IX. A total of 176 days of CGMS data were available. The CGMS was found to be a reliable tool in monitoring glucose levels and trends at all times of the day with good concordance with finger-stick glucose values. This study revealed that in addition to overnight hypoglycemia, CGMS can uncover previously undetected, subclinical, low glucose levels during daytime hours. Additionally, the CGMS detected daytime and overnight hyperglycemia, an often overlooked concern in liver GSDs. The CGMS with concurrent dietary adjustments made by a metabolic dietitian improved metabolic parameters and stabilized blood glucose levels. The CGMS was found to be a safe, effective, and reliable method for optimizing treatment in patients with GSD I, III, and IX.
引用
收藏
页码:917 / 927
页数:11
相关论文
共 50 条
  • [41] The Role of Continuous Monitoring in Atrial Fibrillation Management
    Camm, A. John
    ARRHYTHMIA & ELECTROPHYSIOLOGY REVIEW, 2014, 3 (01) : 48 - 50
  • [42] Severe allergic contact dermatitis to two different continuous glucose monitoring devices in a patient with glycogen storage disease type 9b
    Teufel-Schaefer, Ulrike
    Huhn, Christian
    Mueller, Sabine
    Mueller, Christoph
    Gruenert, Sarah Catharina
    PEDIATRIC DERMATOLOGY, 2021, 38 (05) : 1302 - 1304
  • [43] Continuous glucose monitoring metrics in people with liver glycogen storage disease and idiopathic ketotic hypoglycemia: A single-center, retrospective, observational study
    Overduin, Ruben J.
    Venema, Annieke
    Lubout, Charlotte M. A.
    Fokkert-Wilts, Marieke J.
    De Boer, Foekje
    Schreuder, Andrea B.
    Rossi, Alessandro
    Derks, Terry G. J.
    MOLECULAR GENETICS AND METABOLISM, 2024, 143 (1-2)
  • [44] Continuous glucose monitoring
    Lewis, Dana M.
    Oser, Tamara K.
    Wheeler, Benjamin J.
    BMJ-BRITISH MEDICAL JOURNAL, 2023, 380
  • [45] Continuous glucose monitoring: transforming diabetes management step by step
    Bergenstal, Richard M.
    LANCET, 2018, 391 (10128): : 1334 - 1336
  • [46] Use of Continuous Glucose Monitoring System in the Management of Severe Hypoglycemia
    Ryan, Edmond A.
    Germsheid, Judy
    DIABETES TECHNOLOGY & THERAPEUTICS, 2009, 11 (10) : 635 - 639
  • [47] Use of continuous glucose monitoring to improve diabetes mellitus management
    Ellis, Samuel L.
    Bookout, Tevin
    Garg, Satish K.
    Izuora, Kenneth E.
    ENDOCRINOLOGY AND METABOLISM CLINICS OF NORTH AMERICA, 2007, 36 : 46 - 68
  • [48] Continuous glucose monitoring
    Harris, Stewart B.
    Bari, Basel
    Gilbert, Jeremy
    CANADIAN MEDICAL ASSOCIATION JOURNAL, 2024, 196 (09) : E325 - E326
  • [49] Accuracy of Continuous Glucose Monitoring (CGM) for Inpatient Diabetes Management
    Wright, Jordan J.
    Williams, Alexander
    Weaver, Rita
    Williams, Jonathan M.
    Bao, Shichun
    DIABETES, 2021, 70
  • [50] Application and management of continuous glucose monitoring in diabetic kidney disease
    Zhang, Xin-Miao
    Shen, Quan-Quan
    WORLD JOURNAL OF DIABETES, 2024, 15 (04)