Use of Continuous Glucose Monitoring System in the Management of Severe Hypoglycemia

被引:14
|
作者
Ryan, Edmond A. [1 ]
Germsheid, Judy [1 ]
机构
[1] Univ Alberta, Heritage Med Res Ctr 362, Div Endocrinol & Metab, Dept Med,Alberta Diabet Inst, Edmonton, AB T6G 2S2, Canada
关键词
ISLET TRANSPLANTATION; TYPE-1; IDDM; COUNTERREGULATION; UNAWARENESS; ACCURACY; FREQUENT; RISK;
D O I
10.1089/dia.2009.0042
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Severe hypoglycemia can have a dramatic impact on daily life for people with diabetes. Hypoglycemia is quantifiable by the HYPO-Score derived from the frequency of severe hypoglycemia over a year and a component based on 4 weeks of glucose records. The latter gives a modified HYPO-Score as a short-term measure of hypoglycemia. We used a continuous glucose monitoring system (CGMS) in patients with severe hypoglycemia to assess if we could decrease hypoglycemia as measured by the modified HYPO-Score. Methods: Sixteen type 1 diabetes subjects, 52.0 +/- 2.3 years old with a diabetes duration of 29.4 +/- 2.8 years having problematic hypoglycemia were enrolled. All used multiple daily insulin injections, and the glycosylated hemoglobin level was 8.4 +/- 0.3%. After a month of gathering hypoglycemia information for baseline modified HYPO-Score, subjects wore the CGMS for 2 months, and a modified HYPO-Score was repeated. To assess long-term benefit, CGMS was then discontinued for 3 months, and a final modified HYPO-Score was determined. Results: The modified HYPO-Score decreased from 857 +/- 184 to 444 +/- 92 (P = 0.055) (intention-to-treat basis). Further analysis of the modified HYPO-Score when the CGMS was actually functioning showed it decreased from 857 +/- 184 to 366 +/- 86 (P = 0.023). Severe hypoglycemia episodes dropped from 16 at baseline to three when wearing the CGMS. The number of hypoglycemia episodes <3.0mmol/L dropped from 8.6 +/- 1.5 to 4.7 +/- 0.9 (P = 0.01). Subjects expressed less fear of hypoglycemia with CGMS. In 11 who completed modified Final Month HYPO-Scores, the number of severe hypoglycemic events rose to six. At study end, 13 of 16 subjects elected to continue using the CGMS. Conclusions: When the CGMS was worn and functioning there was a significant decrease in the modified HYPO-Score and number of hypoglycemic values <3.0mmol/L.
引用
收藏
页码:635 / 639
页数:5
相关论文
共 50 条
  • [1] Continuous glucose monitoring system (CGMS) in hypoglycemia
    Harwood, K
    Aponte, L
    Rincon, M
    DiMartino-Nardi, J
    Muzumdar, R
    Saenger, P
    PEDIATRIC RESEARCH, 2004, 55 (04) : 149A - 149A
  • [2] Detection of Hypoglycemia with the continuous glucose monitoring system
    Sibenaler, A
    Boullu-Sanchis, S
    Jean-Didier, N
    Pingét, M
    Meyer, L
    DIABETES, 2003, 52 : A99 - A99
  • [3] Reduction in severe hypoglycemia following use of Continuous Glucose Monitoring: A pilot study.
    Davidson, PC
    Sabbah, H
    McCulloch, K
    Bode, BW
    DIABETOLOGIA, 2001, 44 : A218 - A218
  • [4] IMPAIRED AWARENESS OF HYPOGLYCEMIA CONTINUES TO BE A RISK FACTOR FOR SEVERE HYPOGLYCEMIA DESPITE THE USE OF CONTINUOUS GLUCOSE MONITORING SYSTEM IN TYPE 1 DIABETES
    Lin, Yu Kuei
    Hung, Man
    Sharma, Anu
    Chan, Owen
    Varner, Michael W.
    Staskus, Gitana
    Fisher, Simon J.
    ENDOCRINE PRACTICE, 2019, 25 (06) : 517 - 525
  • [5] Use of Continuous Glucose Monitoring to Prevent Hypoglycemia in the Hospital
    Faulds, Eileen
    Mapes, Sheila
    Karnes, Lindsey
    Dungan, Kathleen M.
    Wyne, Kathleen
    DIABETES, 2016, 65 : A544 - A545
  • [6] RE: RE: IMPAIRED AWARENESS OF HYPOGLYCEMIA CONTINUES TO BE A RISK FACTOR FOR SEVERE HYPOGLYCEMIA DESPITE THE USE OF CONTINUOUS GLUCOSE MONITORING SYSTEM IN TYPE 1 DIABETES
    Lin, Yu Kuei
    Chan, Owen
    Fisher, Simon J.
    ENDOCRINE PRACTICE, 2019, 25 (10) : 1080 - 1081
  • [7] CORRESPONDENCE REGARDING "IMPAIRED AWARENESS OF HYPOGLYCEMIA CONTINUES TO BE A RISK FACTOR FOR SEVERE HYPOGLYCEMIA DESPITE THE USE OF CONTINUOUS GLUCOSE MONITORING SYSTEM IN TYPE 1 DIABETES"
    Price, David A.
    Welsh, John B.
    ENDOCRINE PRACTICE, 2019, 25 (10) : 1079 - 1079
  • [8] Reduction in severe hypoglycemia following use of continuous glucose monitoring to guide therapy adjustments: A pilot study
    Sabbah, H
    McCulloch, K
    Davidson, PC
    Bode, BW
    DIABETES, 2001, 50 : A449 - A449
  • [9] Neonatal hypoglycemia: continuous glucose monitoring
    Shah, Rajesh
    McKinlay, Christopher J. D.
    Harding, Jane E.
    CURRENT OPINION IN PEDIATRICS, 2018, 30 (02) : 204 - 208
  • [10] Efficacy of Intermittently Scanned Continuous Glucose Monitoring in the Prevention of Recurrent Severe Hypoglycemia
    Davis, Timothy M. E.
    Dwyer, Penny
    England, Michelle
    Fegan, P. Gerry
    Davis, Wendy A.
    DIABETES TECHNOLOGY & THERAPEUTICS, 2020, 22 (05) : 367 - 373