Simulated and developed an electron impact ionization source for space miniature time-of-flight mass spectrometer

被引:10
|
作者
Ren, Zhengyi [1 ]
Guo, Meiru [1 ]
Cheng, Yongjun [1 ]
Sun, Wenjun [1 ]
Dong, Meng [1 ]
Li, Gang [1 ]
Pei, Xiaoqiang [1 ]
Wu, Chengyao [1 ]
机构
[1] Lanzhou Inst Phys, Sci & Technol Vacuum Technol & Phys Lab, Lanzhou 730000, Peoples R China
基金
中国国家自然科学基金;
关键词
EI source; Phase space; SIMION; 8.1; simulation; RTOF MS; ION;
D O I
10.1016/j.vacuum.2020.109207
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Based on the ions initial distribution and electrodes parameters of electron impact (EI) ionization source, the physical model of miniature EI source is developed by SIMION 8.1. By using the phase space analysis method, we have researched the influence of the initial position of ions voltage parameters of electrodes on focusing performance, ion transmission efficiency and velocity distribution of ions when they exited from the focusing electrode. It is found that when negative voltage is applied to the object slit S of the EI source, the position and velocity distributions of the ions at the exit are minimized, the performance of the EI source is greatly improved due to the secondary focusing of the ions in this case. Based on the above research, we developed the integrated EI source, the EI source's overall size is 12 mm wide, 24 mm long and 12 mm tall, it weighs 0.1 kg, and its power consumption was measured to be 1 W. Finally, the primary performance of the EI source coupled to reflection time-of-flight mass spectrometer (RTOF MS) is evaluated and the experiment results are consistent with simulation results.
引用
下载
收藏
页数:8
相关论文
共 50 条
  • [21] Design and performance of an electrospray ionization time-of-flight mass spectrometer
    Håkansson, K
    Zubarev, RA
    Håkansson, P
    Laiko, V
    Dodonov, AF
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2000, 71 (01): : 36 - 41
  • [22] Miniature time-of-flight mass spectrometer using a flexible circuitboard reflector
    Cornish, TJ
    Ecelberger, S
    Brinckerhoff, W
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2000, 14 (24) : 2408 - 2411
  • [23] Delayed extraction time-of-flight mass spectrometer with electron impact for PAH studies
    Najeeb, P. K.
    Kadhane, U.
    JOURNAL OF INSTRUMENTATION, 2017, 12
  • [24] A TIME-OF-FLIGHT MASS SPECTROMETER
    WILSON, DB
    VACUUM, 1969, 19 (07) : 323 - &
  • [25] A TIME-OF-FLIGHT MASS SPECTROMETER
    GOUDSMIT, SA
    PHYSICAL REVIEW, 1948, 74 (05): : 622 - 623
  • [26] A TIME-OF-FLIGHT MASS SPECTROMETER
    KATZENSTEIN, HS
    FRIEDLAND, SS
    PHYSICAL REVIEW, 1954, 93 (02): : 363 - 363
  • [27] IMPROVED DETECTION LIMITS FOR A TIME-OF-FLIGHT MASS-SPECTROMETER WITH A SURFACE-IONIZATION SOURCE
    CHATFIELD, DA
    AJAMI, M
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1987, 77 (2-3): : 241 - 256
  • [28] Development of a portable time-of-flight mass spectrometer prototype using a cold electron source
    Jeong, Wanseop
    Kim, Hyun Sik
    Kang, Byeongwon
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2022, 93 (02):
  • [29] A PHOTOEMITTED ELECTRON-IMPACT IONIZATION METHOD FOR TIME-OF-FLIGHT MASS SPECTROMETERS
    CHENG, PY
    DAI, HL
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1993, 64 (08): : 2211 - 2214
  • [30] A MOLECULAR-BEAM TIME-OF-FLIGHT MASS-SPECTROMETER USING LOW-ENERGY-ELECTRON IMPACT IONIZATION
    HAYDEN, CC
    PENN, SM
    MUYSKENS, KJC
    CRIM, FF
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1990, 61 (02): : 775 - 782