Normalization of vasomotion in laser Doppler perfusion monitoring

被引:4
|
作者
Graaff, Reindert [1 ]
Morales, Fernando [1 ]
Smit, Andries J.
de Jong, Ed D. [1 ]
de Mul, Frits F. A. [1 ]
Rakhorst, Gerhard [1 ]
机构
[1] Univ Groningen, Univ Med Ctr Groningen, Dept Biomed Engn, NL-9713 EZ Groningen, Netherlands
关键词
D O I
10.1109/IEMBS.2007.4353229
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Laser Doppler flux signals show temporal fluctuations caused by physiological phenomena like heartbeat, respiration, and local variation of vascular tonus, vasomotion. This study investigates the influence of fiber arrangement, equipment and two probe locations on the variations in laser Doppler flux signals in five frequency bands in the absence of provocations. Two probes with detecting optical fibers at several distances from the illuminating source were used, as well as instruments from two manufacturers. The results show that normalization of the filtered flux signals with the mean flux leads to an enormous decrease of the influence of fiber distance. The difference between instruments is small after normalization. Some influence of probe location remains after normalization. Development of a standard method for normalization of the variations in laser Doppler signals is recommended.
引用
收藏
页码:4076 / 4079
页数:4
相关论文
共 50 条
  • [21] Full-field laser Doppler perfusion imaging and monitoring with an intelligent CMOS camera
    Serov, A
    Steinacher, B
    Lasser, T
    OPTICS EXPRESS, 2005, 13 (10): : 3681 - 3689
  • [22] Correlation between laser Doppler perfusion monitoring and hematocrit in hamster cheek pouch microcirculation
    Colantuoni, A
    Bertuglia, S
    INTERNATIONAL JOURNAL OF MICROCIRCULATION-CLINICAL AND EXPERIMENTAL, 1997, 17 (01): : 33 - 40
  • [23] Laser Doppler perfusion monitoring and imaging especially as regards testing for sympathetic nerve function
    Freccero, C.
    Wollmer, P.
    Sundkvist, G.
    Svensson, H.
    JOURNAL OF VASCULAR RESEARCH, 2006, 43 : 38 - 38
  • [24] Monitoring of the intestinal mucosal perfusion using laser Doppler flowmetry after multivisceral transplantation
    Oltean, M
    Aneman, A
    Dindelegan, G
    Mölne, J
    Olausson, M
    Herlenius, G
    TRANSPLANTATION PROCEEDINGS, 2005, 37 (08) : 3323 - 3324
  • [25] Analysis and processing of laser Doppler perfusion monitoring signals recorded from the beating heart
    M. G. D. Karlsson
    H. Casimir-Ahn
    U. Lönn
    K. Wårdell
    Medical and Biological Engineering and Computing, 2003, 41 : 255 - 262
  • [26] A system for on-line laser Doppler monitoring of ECG-traced myocardial perfusion
    Fors, C
    Karlsson, MGD
    Ahn, HC
    Wårdell, K
    PROCEEDINGS OF THE 26TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-7, 2004, 26 : 3796 - 3799
  • [27] Perfusion of the femoral head during surgical dislocation of the hip -: Monitoring by laser doppler flowmetry
    Nötzli, HP
    Siebenrock, KA
    Hempfing, A
    Ramseier, LE
    Ganz, R
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2002, 84B (02): : 300 - 304
  • [28] Integrated probes containing a VCSEL and a multidetector chip, for laser Doppler tissue perfusion monitoring
    Serov, AN
    Oosterbaan, S
    Nieland, J
    van Kranenburg, H
    de Mul, FFM
    Steenbergen, W
    BIOMEDICAL DIAGNOSTIC, GUIDANCE, AND SURGICAL-ASSIST SYSTEMS III, 2001, 4254 : 119 - 127
  • [29] Analysis and processing of laser Doppler perfusion monitoring signals recorded from the beating heart
    Karlsson, MGD
    Casimir-Ahn, H
    Lönn, U
    Wårdell, K
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2003, 41 (03) : 255 - 262
  • [30] DOPPLER ULTRASOUND, LASER DOPPLER, AND PERFUSION FLUOROMETRY IN BOWEL ISCHEMIA
    LYNCH, TG
    HOBSON, RW
    KERR, JC
    BROUSSEAU, DA
    SILVERMAN, DG
    REILLY, CA
    TSENG, H
    ARCHIVES OF SURGERY, 1988, 123 (04) : 483 - 486