Laser Doppler perfusion monitoring (LDPM) can be used for monitoring myocardial perfusion in the non-beating heart. However, the movement of the beating heart generates large artifacts. Therefore the aim of the study was to develop an LDPM system capable of correlating the laser Doppler signals to the cardiac cycle and to process the signals to reduce the movement artifacts. Measurements were performed on three calves, both on the normal beating heart and during occlusion of the left anterior descending coronary artery (LAD). The recorded LDPM signals were digitally processed and correlated to the sampled ECG. Large variations in the output (perfusion) and DC signals during the cardiac cycle were found, with average coefficients of variation of 0.36 and 0.14 (n-14), respectively. However, sections with a relatively low, stable output signal were found in late diastole, where the movement of the heart is at a minimum. Occlusion of the LAD showed the importance of recording the laser Doppler signals at an appropriate point in the cardiac cycle, in this case late systole, to minimise movement artifacts. It is possible to further reduce movement artifacts by increasing the lower cutoff frequency when calculating the output signal.
引用
收藏
页码:255 / 262
页数:7
相关论文
共 50 条
  • [1] Analysis and processing of laser Doppler perfusion monitoring signals recorded from the beating heart
    Karlsson, MGD
    Casimir-Ahn, H
    Lönn, U
    Wårdell, K
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2003, 41 (03) : 255 - 262
  • [2] Higher order moment processing of laser Doppler perfusion signals
    Linkoping Univ, Linkoping, Sweden
    J Biomed Opt, 4 (358-363):
  • [3] ASSESSMENT OF MYOCARDIAL PERFUSION IN THE EMPTY BEATING PORCINE HEART WITH LASER DOPPLER FLOWMETRY
    AHN, HC
    EKROTH, R
    HEDENMARK, J
    NILSSON, GE
    SVEDJEHOLM, R
    CARDIOVASCULAR RESEARCH, 1988, 22 (10) : 719 - 725
  • [4] ECG-triggering of the laser Doppler signal -: an approach for perfusion imaging on the beating calf heart
    Wårdell, K
    Karlsson, MGD
    Lönn, U
    Träff, S
    Casimir-Ahn, H
    BIOMEDICAL DIAGNOSTIC, GUIDANCE, AND SURGICAL-ASSIST SYSTEMS III, 2001, 4254 : 49 - 57
  • [5] PROCESSING OF LASER DOPPLER VELOCIMETER SIGNALS
    MEYERS, JF
    FELLER, WV
    IEEE TRANSACTIONS ON AEROSPACE AND ELECTRONIC SYSTEMS, 1973, AES9 (05) : 823 - 823
  • [6] ANALYSIS OF DOPPLER SIGNALS FROM FETAL HEART
    ABELSON, D
    BALIN, H
    AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 1972, 112 (06) : 796 - &
  • [7] Normalization of vasomotion in laser Doppler perfusion monitoring
    Graaff, Reindert
    Morales, Fernando
    Smit, Andries J.
    de Jong, Ed D.
    de Mul, Frits F. A.
    Rakhorst, Gerhard
    2007 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-16, 2007, : 4076 - 4079
  • [8] Developments in laser Doppler blood perfusion monitoring
    Leahy, MJ
    de Mul, FFM
    Nilsson, GE
    Maniewski, R
    Liebert, A
    OPTO-IRELAND 2002: OPTICS AND PHOTONICS TECHNOLOGIES AND APPLICATIONS, PTS 1 AND 2, 2003, 4876 : 128 - 139
  • [9] Analysis of digital spectral processing of laser Doppler vibration meter signals
    O. A. Evtikhieva
    V. I. Moskalevich
    N. M. Skornyakova
    Measurement Techniques, 2006, 49 : 907 - 912
  • [10] Analysis of digital spectral processing of laser Doppler vibration meter signals
    Evtikhieva, O. A.
    Moskalevich, V. I.
    Skornyakova, N. M.
    MEASUREMENT TECHNIQUES, 2006, 49 (09) : 907 - 912