Golay Coded Sequences in Synthetic Aperture Imaging Systems

被引:18
|
作者
Trots, Ihor [1 ]
Tasinkevych, Yuriy [1 ]
Nowicki, Andrzej [1 ]
Lewandowski, Marcin [1 ]
机构
[1] Polish Acad Sci, Inst Fundamental Technol Res, Dept Ultrasound, PL-02106 Warsaw, Poland
关键词
ultrasound imaging; synthetic aperture; beamforming; radiation pattern; coded sequences; Golay codes; TRANSMIT APERTURE; SCATTERING; WAVE; ARRAY; STRIPS;
D O I
10.2478/v10168-011-0061-5
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
The paper presents the theoretical and experimental study of synthetic transmit aperture (STA) method combined with Go lay coded transmission for medical ultrasound imaging applications. The transmission of long waveforms characterized by a particular autocorrelation function allows to increase the total energy of the transmitted signal without increasing the peak pressure. It can also improve signal-to-noise ratio and increase the visualization depth maintaining the ultrasound image resolution. In the work the 128-element linear transducer array with 0.3 mm pitch excited by the 8 and 16-bits Go lay coded sequences as well as a one cycle at nominal frequencies 4 MHz were used. The comparison of 2D ultrasound images of the tissue mimicking phantoms is presented to demonstrate the benefits of coded transmission. The image reconstruction was performed using synthetic STA algorithm with transmit and receive signals correction based on a single element directivity function.
引用
收藏
页码:913 / 926
页数:14
相关论文
共 50 条
  • [31] Mutually orthogonal Golay complementary sequences in the simultaneous synthetic aperture method for medical ultrasound diagnostics. An experimental study
    Tasinkevych, Y.
    Trots, I.
    Nowicki, A.
    Ultrasonics, 2021, 115
  • [32] Coded excitation waveform engineering for high frame rate synthetic aperture ultrasound imaging
    Lashkari, Bahman
    Zhang, Kaicheng
    Dovlo, Edem
    Mandelis, Andreas
    ULTRASONICS, 2017, 77 : 121 - 132
  • [33] Optimization of sparse. synthetic transmit aperture imaging with coded excitation and frequency division
    Behar, V
    Adam, D
    ULTRASONICS, 2005, 43 (10) : 777 - 788
  • [34] Mutually orthogonal Golay complementary sequences in the simultaneous synthetic aperture method for medical ultrasound diagnostics. An experimental study
    Tasinkevych, Y.
    Trots, I.
    Nowicki, A.
    ULTRASONICS, 2021, 115
  • [35] Active Coded Aperture Neutron Imaging
    Marleau, Peter
    Brennan, James
    Brubaker, Erik
    Hilton, Nathan
    Steele, John
    2009 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2009, : 1974 - 1977
  • [36] SNR of the coded aperture imaging system
    Wang, Jianwei
    Zhao, Yan
    OPTICAL REVIEW, 2021, 28 (01) : 106 - 112
  • [37] CODED APERTURE IMAGING ON NONPLANAR SURFACES
    ATCHESON, PD
    JOURNAL OF THE OPTICAL SOCIETY OF AMERICA, 1976, 66 (10) : 1110 - 1110
  • [38] IMAGING WITH CODED-APERTURE MASKS
    SKINNER, GK
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1984, 221 (01): : 33 - 40
  • [39] Periodic wrappings in coded aperture imaging
    Shutler, Paul M. E.
    Springham, Stuart V.
    Talebitaher, Alireza
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2014, 738 : 132 - 148
  • [40] Coded aperture compressive temporal imaging
    Llull, Patrick
    Liao, Xuejun
    Yuan, Xin
    Yang, Jianbo
    Kittle, David
    Carin, Lawrence
    Sapiro, Guillermo
    Brady, David J.
    OPTICS EXPRESS, 2013, 21 (09): : 10526 - 10545