摘要
The paper presents the theoretical and experimental study of synthetic transmit aperture (STA) method combined with Go lay coded transmission for medical ultrasound imaging applications. The transmission of long waveforms characterized by a particular autocorrelation function allows to increase the total energy of the transmitted signal without increasing the peak pressure. It can also improve signal-to-noise ratio and increase the visualization depth maintaining the ultrasound image resolution. In the work the 128-element linear transducer array with 0.3 mm pitch excited by the 8 and 16-bits Go lay coded sequences as well as a one cycle at nominal frequencies 4 MHz were used. The comparison of 2D ultrasound images of the tissue mimicking phantoms is presented to demonstrate the benefits of coded transmission. The image reconstruction was performed using synthetic STA algorithm with transmit and receive signals correction based on a single element directivity function.
引用
收藏
页码:913 / 926
页数:14
相关论文
共 50 条
  • [21] Coded aperture compressive imaging array applied for surveillance systems
    Chen, Jing
    Wang, Yongtian
    Wu, Hanxiao
    JOURNAL OF SYSTEMS ENGINEERING AND ELECTRONICS, 2013, 24 (06) : 1019 - 1028
  • [22] Shifted Coded Aperture Design for Single Pixel Imaging Systems
    Mojica, Edson
    Guaiquil, Jorge
    Tajahuerce, Enrique
    Meza, Pablo
    COMPUTATIONAL OPTICS 2024, 2024, 13023
  • [23] Coded aperture compressive imaging array applied for surveillance systems
    Jing Chen
    Yongtian Wang
    Hanxiao Wu
    Journal of Systems Engineering and Electronics, 2013, 24 (06) : 1019 - 1028
  • [24] Partial aperture imaging by systems with annular phase coded masks
    Bulbul, Angika
    Vijayakumar, A.
    Rosen, Joseph
    OPTICS EXPRESS, 2017, 25 (26): : 33315 - 33329
  • [25] Compressive Coded Aperture Imaging
    Marcia, Roummel F.
    Harmany, Zachary T.
    Willett, Rebecca M.
    COMPUTATIONAL IMAGING VII, 2009, 7246
  • [26] CODED APERTURE IMAGING OF HEART
    ROGERS, WL
    KORAL, KF
    MAYANS, R
    LEONARD, PF
    KEYES, JW
    JOURNAL OF NUCLEAR MEDICINE, 1978, 19 (06) : 730 - 730
  • [27] High frequency imaging using coded Golay transmission
    Nowicki, A
    Lewandowski, M
    Secomski, W
    Litniewski, J
    Tymkiewicz, R
    2005 IEEE Ultrasonics Symposium, Vols 1-4, 2005, : 2058 - 2061
  • [28] Mutually Orthogonal Complementary Golay Coded Sequences: An In-vivo Study
    Trots, Ihor
    Tasinkiewicz, Jurij
    Nowicki, Andrzej
    ARCHIVES OF ACOUSTICS, 2024, 49 (03) : 429 - 437
  • [29] SYNTHETIC-APERTURE RADAR IMAGING-SYSTEMS
    BIRK, R
    CAMUS, W
    VALENTI, E
    MCCANDLESS, W
    IEEE AEROSPACE AND ELECTRONIC SYSTEMS MAGAZINE, 1995, 10 (11) : 15 - 23
  • [30] An overview of Integrated Sensing and Processing using coded aperture imaging systems
    Mahalanobis, Abhijit
    Muise, Robert
    INFORMATION OPTICS, 2006, 860 : 95 - +