Fast 3D in vivo swept-source optical coherence tomography using a two-axis MEMS scanning micromirror

被引:32
|
作者
Kumar, Karthik [1 ]
Condit, Jonathan C. [2 ]
McElroy, Austin [3 ]
Kemp, Nate J. [3 ]
Hoshino, Kazunori [2 ]
Milner, Thomas E. [2 ]
Zhang, Xiaojing [2 ]
机构
[1] Univ Texas Austin, Dept Elect & Comp Engn, Austin, TX 78712 USA
[2] Univ Texas Austin, Dept Biomed Engn, Austin, TX 78712 USA
[3] CardioSpectra Inc, San Antonio, TX 78229 USA
来源
关键词
optical coherence tomography (OCT); swept-source; MEMS; scanning micromirror; high-speed 3D imaging;
D O I
10.1088/1464-4258/10/4/044013
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
We report on a fibre-based forward-imaging swept-source optical coherence tomography system using a high-reflectivity two-axis microelectromechanical scanning mirror for high-speed 3D in vivo visualization of cellular-scale architecture of biological specimens. The scanning micromirrors, based on electrostatic staggered vertical comb drive actuators, can provide +/- 9 degrees of optical deflection on both rotation axes and uniform reflectivity of greater than 90% over the range of imaging wavelengths (1260-1360 nm), allowing for imaging turbid samples with good signal-to-noise ratio. The wavelength-swept laser, scanning over 100 nm spectrum at 20 kHz rate, enables fast image acquisition at 10.2 million voxels s(-1) (for 3D imaging) or 40 frames s-1 (for 2D imaging with 500 transverse pixels per image) with 8.6 mu m axial resolution. Lateral resolution of 12.5 mu m over 3 mm field of view in each lateral direction is obtained using ZEMAX optical simulations for the lateral beam scanning system across the scanning angle range of the 500 mu m x 700 mu m micromirror. We successfully acquired en face and tomographic images of rigid structures (scanning micromirror), in vitro biological samples (onion peels and pickle slices) and in vivo images of human epidermis over 2 x 1 x 4 mm(3) imaging volume in real time at faster-than-video 2D frame rates. The results indicate that our system framework may be suitable for image-guided minimally invasive examination of various diseased tissues.
引用
收藏
页数:7
相关论文
共 50 条
  • [31] Defect inspection of actuator lenses using swept-source optical coherence tomography
    Lee, Jaeyul
    Shirazi, Muhammad Faizan
    Park, Kibeom
    Jeon, Mansik
    Kim, Jeehyun
    OPTICAL REVIEW, 2018, 25 (03) : 403 - 409
  • [32] Speckle variance detection of microvasculature using swept-source optical coherence tomography
    Mariampillai, Adrian
    Standish, Beau A.
    Moriyama, Eduardo H.
    Khurana, Mamta
    Munce, Nigel R.
    Leung, Michael K. K.
    Jiang, James
    Cable, Alex
    Wilson, Brian C.
    Vitkin, I. Alex
    Yang, Victor X. D.
    OPTICS LETTERS, 2008, 33 (13) : 1530 - 1532
  • [33] Analysis of cariogenic biofilms by using a swept-source optical coherence tomography in vitro
    Tabata, Tomoko
    Nakagawa, Hisaichi
    Matin, Khairul
    Otsuki, Masayuki
    Aoki, Akira
    Sumi, Yasunori
    Shimada, Yasushi
    ARCHIVES OF ORAL BIOLOGY, 2024, 165
  • [34] Off-axis full-field swept-source optical coherence tomography using holographic refocusing
    Hillmann, Dierck
    Franke, Gesa
    Hinkel, Laura
    Bonin, Tim
    Koch, Peter
    Huettmann, Gereon
    OPTICAL COHERENCE TOMOGRAPHY AND COHERENCE DOMAIN OPTICAL METHODS IN BIOMEDICINE XVII, 2013, 8571
  • [35] 3D evaluation of composite resin restoration at practical training using swept-source optical coherence tomography (SS-OCT)
    Shimada, Yasushi
    Sadr, Alireza
    Nazari, Amir
    Nakagawa, Hisaichi
    Otsuki, Masayuki
    Tagami, Junji
    Sumi, Yasunori
    DENTAL MATERIALS JOURNAL, 2012, 31 (03) : 409 - 417
  • [36] Two-reference swept-source optical coherence tomography of high operation flexibility
    Chi, Ting-Ta
    Wu, Chiung-Ting
    Liao, Chen-Chin
    Tu, Yi-Chou
    Kiang, Yean-Woei
    Yang, C. C.
    OPTICS EXPRESS, 2012, 20 (27): : 28418 - 28430
  • [37] Comparison of ocular biometry in Chinese patients using two swept-source optical coherence tomography devices
    Ho, Vivian Wing -Man
    Nguyen, Hong Chau
    Wong, Siu-Hong
    Li, Anita Lai-Wah
    Li, Kenneth Kai Wang
    ANNALS OF EYE SCIENCE, 2023, 8
  • [38] Comparison of Precision, Agreement, and Accuracy of Two Swept-Source Optical Coherence Tomography Biometers
    Guarro, Merce
    Vazquez, Meritxell
    Diaz, Juan Carlos
    Ruiz, Sergi
    Gimeno, Maties
    Rodriguez, Lara
    Lopez, Elena
    Sararols, Laura
    Biarnes, Marc
    DIAGNOSTICS, 2024, 14 (21)
  • [39] Comparison of two biometers: A swept-source optical coherence tomography and an optical low-coherence reflectometry biometer
    El Chehab, Hussam
    Agard, Emilie
    Dot, Corinne
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2019, 29 (05) : 547 - 554
  • [40] Comparison study of the two biometers based on swept-source optical coherence tomography technology
    Wang, Xiaogang
    Dong, Jing
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2022, 63 (07)