Repeatability Investigation of Reduced Field-of-View Diffusion-Weighted Magnetic Resonance Imaging on Thyroid Glands

被引:8
|
作者
Lu, Yonggang [1 ]
Hatzoglou, Vaios [2 ]
Banerjee, Suchandrima [3 ]
Stambuk, Hilda E. [2 ]
Gonen, Mithat [4 ]
Shankaranarayanan, Ajit [3 ]
Mazaheri, Yousef [1 ,2 ]
Deasy, Joseph O. [1 ]
Shaha, Ashok R. [5 ]
Tuttle, R. Michael [6 ]
Shukla-Dave, Amita [1 ,2 ]
机构
[1] Mem Sloan Kettering Canc Ctr, Dept Med Phys, New York, NY 10065 USA
[2] Mem Sloan Kettering Canc Ctr, Dept Radiol, New York, NY 10065 USA
[3] GE Healthcare, Global Appl Sci Lab, Menlo Pk, CA USA
[4] Mem Sloan Kettering Canc Ctr, Dept Epidemiol & Biostat, New York, NY 10065 USA
[5] Mem Sloan Kettering Canc Ctr, Dept Surg, New York, NY 10065 USA
[6] Mem Sloan Kettering Canc Ctr, Dept Med, New York, NY 10065 USA
基金
美国国家卫生研究院;
关键词
reduced field-of-view diffusion-weighted imaging; repeatability; thyroid glands; SPINAL-CORD; DIFFERENTIATE BENIGN; TREATMENT RESPONSE; BREAST-CANCER; NODULES; COEFFICIENT; MRI; UTILITY; HEAD;
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: To investigate the repeatability of the quantitative magnetic resonance imaging (MRI) metric (apparent diffusion coefficient [ADC]) derived from reduced field-of-view diffusion-weighted (rFOV DWI) on thyroid glands in a clinical setting. Materials and Methods: Ten healthy human volunteers were enrolled in MRI studies performed on a 3-T MRI scanner. Each volunteer was designed to undergo 3 longitudinal examinations (2 weeks apart) with 2 repetitive sessions within each examination, which included rFOV and conventional full field-of-view (fFOV) DWI scans. Diffusion-weighted images were assessed and scored based on image characteristics. Apparent diffusion coefficient values of thyroid glands from all participants were calculated based on regions of interest. Repeatability analysis was performed based on the framework proposed by the Quantitative Imaging Biomarker Alliance, generating 4 repeatability metrics: within-participant variance (sigma(2)(w)), repeatability coefficients, intraclass correlation coefficient, and within-participant coefficient of variation. Student t test was used to compare the performance difference between rFOV and fFOV DWI. Results: The overall image quality from rFOV DWI was significantly higher than that from fFOV DWI (P = 0.04). The ADC values calculated from rFOV DWI were significantly lower than corresponding values from fFOV DWI (P < 0.001). There was no significant difference in ADC values across sessions and examinations in either rFOV or fFOV DWI (P > 0.05). Reduced field-of-view DWI had lower values of sigma(2)(w), repeatability coefficient, and within-participant coefficient of variation and had a higher value of intraclass correlation coefficient compared with fFOV DWI across either sessions or examinations. Conclusions: This study demonstrated that rFOV DWI produced more superior-quality DWI images and more repeatable ADC measurements compared with fFOV DWI, thus providing a feasible quantitative imaging tool for investigating thyroid glands in clinical settings.
引用
收藏
页码:334 / 339
页数:6
相关论文
共 50 条
  • [21] Preoperative staging of endometrial cancer using reduced field-of-view diffusion-weighted imaging: a preliminary study
    Ota, Takashi
    Hori, Masatoshi
    Onishi, Hiromitsu
    Sakane, Makoto
    Tsuboyama, Takahiro
    Tatsumi, Mitsuaki
    Nakamoto, Atsushi
    Kimura, Tadashi
    Narumi, Yoshifumi
    Tomiyama, Noriyuki
    EUROPEAN RADIOLOGY, 2017, 27 (12) : 5225 - 5235
  • [22] Reduced field-of-view diffusion-weighted MR imaging for assessing the local extent of uterine cervical cancer
    Takeuchi, Mayumi
    Matsuzaki, Kenji
    Bando, Yoshimi
    Harada, Masafumi
    ACTA RADIOLOGICA, 2020, 61 (02) : 267 - 275
  • [23] Diffusion-weighted MRI of solid pancreatic lesions: Comparison between reduced field-of-view and large field-of-view sequences
    Donati, Francescamaria
    Casini, Chiara
    Cervelli, Rosa
    Morganti, Riccardo
    Boraschi, Piero
    EUROPEAN JOURNAL OF RADIOLOGY, 2021, 143
  • [24] Diffusion-weighted magnetic resonance imaging for the detection of thyroid cancer
    Ekinci, Ozgur
    Boluk, Sumeyra Emine
    Eren, Tunc
    Ozemir, Ibrahim Ali
    Boluk, Salih
    Salmaslioglu, Artur
    Leblebici, Metin
    Alimoglu, Orhan
    CIRUGIA ESPANOLA, 2018, 96 (10): : 620 - 626
  • [25] Use of Reduced Field-of-View Acquisition to Improve Prostate Cancer Visualization on Diffusion-Weighted Magnetic Resonance Imaging in the Presence of Hip Implants: Report of 2 Cases
    Rosenkrantz, Andrew B.
    Taneja, Samir S.
    CURRENT PROBLEMS IN DIAGNOSTIC RADIOLOGY, 2018, 47 (02) : 125 - 127
  • [26] Gallbladder carcinoma: an initial clinical experience of reduced field-of-view diffusion-weighted MRI
    Wu, Sisi
    Zou, Xianlun
    Wang, Qiuxia
    Hu, Daoyu
    Li, Zhen
    Xu, Chuou
    CANCER IMAGING, 2020, 20 (01)
  • [27] Gallbladder carcinoma: an initial clinical experience of reduced field-of-view diffusion-weighted MRI
    Sisi Wu
    Xianlun Zou
    Qiuxia Wang
    Daoyu Hu
    Zhen Li
    Chuou Xu
    Cancer Imaging, 20
  • [28] Diffusion-weighted magnetic resonance imaging
    Mukherji, SK
    Chenevert, TL
    Castillo, M
    JOURNAL OF NEURO-OPHTHALMOLOGY, 2002, 22 (02) : 118 - 122
  • [29] Reduced Field-of-View Diffusion-Weighted Magnetic Resonance Imaging of the Prostate at 3 Tesla: Comparison With Standard Echo-Planar Imaging Technique for Image Quality and Tumor Assessment
    Tamada, Tsutomu
    Ream, Justin M.
    Doshi, Ankur M.
    Taneja, Samir S.
    Rosenkrantz, Andrew B.
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2017, 41 (06) : 949 - 956
  • [30] Reduced field-of-view versus full field-of-view diffusion-weighted imaging for the evaluation of complete response to neoadjuvant chemoradiotherapy in patients with locally advanced rectal cancer
    Siwon Jang
    Jeong Min Lee
    Jeong Hee Yoon
    Jae Seok Bae
    Abdominal Radiology, 2021, 46 : 1468 - 1477