A method to enhance spatial resolution of a 2D ion chamber array for quality control of MLC

被引:4
|
作者
Diaz Moreno, Rogelio [1 ]
Venencia, Daniel [2 ]
Garrigo, Edgardo [2 ]
Pipman, Yakov [3 ]
机构
[1] Inst Neurol & Neurocirugia, Dept Neurocirugia, Havana, Cuba
[2] Inst Privado Radioterapia, Cordoba, Argentina
[3] NSLIJ Hlth Syst, Dept Radiat Med, New Hyde Pk, NY USA
来源
关键词
multileaf collimator; quality control; 2D detector array; partial volume response of detector; INTENSITY-MODULATED RADIOTHERAPY; ASSURANCE; VERIFICATION; DELIVERY;
D O I
10.1120/jacmp.v12i4.3456
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
This work introduces a new method for verifying MLC leaf positions with enough spatial resolution to replace film-based methods in performing QA tests. It is implemented on a 2D ion chamber array, and it is based on the principle of varying signal response of a volumetric detector to partial irradiation. A PTW 2D-ARRAY seven29 (PTW-729 2D) array was used to assess a Siemens OPTIFOCUS MLC. Partial volume response curves for chambers in the array were obtained by irradiating them with the leaves of the MLC, progressively covering varying portions of the chambers correlated with the leaf positions. The readings from the array's chambers are processed with an in-house program; it generates a reference response that translates readings into leaf positions. This principle allows discriminating errors in pairs of opposing leaves that could combine to cancel their detection with other tools. Patterns of leaf positions, similar to the Bayouth test but with different, purposefully introduced errors, were generated and used to test the effectiveness of the method. The same patterns were exposed on radiographic film and analyzed with the RIT software for validation. For four test patterns with a total of 100 errors of +/- 1 mm, +/- 2 mm and +/- 3 mm, all were correctly determined with the proposed method. The analysis of the same pattern with film using the Bayouth routine in the RIT software resulted in either somewhat low true positives combined with a large fraction of false positives, or a low true positive rate with a low false positive ratio, the results being significantly affected by the threshold selected for the analysis. This method provides an effective, easy to use tool for quantitative MLC QA assessment, with excellent spatial resolution. It can be easily applied to other 2D arrays, as long as they exhibit a partial volume detector response.
引用
收藏
页码:63 / 73
页数:11
相关论文
共 50 条
  • [21] Measuring field parameters of a linear accelerator with a 2D ion chamber array
    Henkner, K.
    Rhein, B.
    RADIOTHERAPY AND ONCOLOGY, 2007, 84 : S192 - S193
  • [22] A multiple acquisition sequence for IMRT verification with a 2D ion chamber array
    Spezi, Emiliano
    Angelini, Anna Lisa
    Ferri, Andrea
    MEDICAL DOSIMETRY, 2006, 31 (04) : 269 - 272
  • [23] Verification measurements of an eMC algorithm using a 2D ion chamber array
    Wanklyn, Mark D.
    Kidane, Ghirmay
    Crees, Liz
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2016, 17 (05): : 320 - 328
  • [24] Dosimetric verification of enhanced dynamic wedges by a 2D ion chamber array
    Oh, Se An
    Kim, Sung Kyu
    Kang, Min Kyu
    Yea, Ji Woon
    Kim, Eng Chan
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2013, 63 (11) : 2215 - 2219
  • [25] Dosimetric verification of enhanced dynamic wedges by a 2D ion chamber array
    Se An Oh
    Sung Kyu Kim
    Min Kyu Kang
    Ji Woon Yea
    Eng Chan Kim
    Journal of the Korean Physical Society, 2013, 63 : 2215 - 2219
  • [26] A Systematic Study On the Angular Dependence of 2D Ion Chamber Array for Accurate IMRT Plan Quality Assurance
    Xu, J.
    Liu, J.
    Veltchev, I.
    Ma, C.
    MEDICAL PHYSICS, 2020, 47 (06) : E691 - E691
  • [27] VMAT Monthly Quality Assurance Using a 2D Ionization Chamber Array
    Myers, P.
    Buckey, C.
    Mihailidis, D.
    Mavroidis, P.
    Esquivel, C.
    Gutierrez, A.
    Papanikolaou, N.
    Stathakis, S.
    MEDICAL PHYSICS, 2011, 38 (06)
  • [28] Determination of the effective chamber position of 2D ion chamber array using an HDR afterloading device
    Biggs, P.
    MEDICAL PHYSICS, 2006, 33 (06) : 2085 - 2085
  • [29] Application of a 2-D ion chamber array for dose verification of dynamic IMRT with a micro-MLC
    Araki, F.
    Tajiri, S.
    Tominaga, H.
    Kawasaki, K.
    Kogo, K.
    Yoshitani, M.
    Mueller, L.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2006, 66 (03): : S703 - S704
  • [30] QA of a tomotherapy unit by means of a 2D ion chamber array and the octavius phantom
    Hambach, L.
    Clermont, C.
    Devillers, M.
    Van Esch, A.
    Huyskens, D.
    RADIOTHERAPY AND ONCOLOGY, 2007, 84 : S82 - S82