Full-scale experimental study on masonry infilled RC moment-resisting frames under cyclic loads

被引:65
|
作者
Jiang, Huanjun
Liu, Xiaojuan [1 ]
Mao, Junjie
机构
[1] Tongji Univ, State Key Lab Disaster Reduct Civil Engn, Shanghai 200092, Peoples R China
基金
中国国家自然科学基金;
关键词
Infill wall; Reinforced concrete moment-resisting frame; Connection detail; Cyclic loading test; Seismic performance; REINFORCED-CONCRETE FRAMES; BUILDINGS; BEHAVIOR; PANELS; TESTS;
D O I
10.1016/j.engstruct.2015.02.008
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The reinforced concrete (RC) moment-resisting frames with masonry infill walls are widely used in buildings. It has been well recognized that the arrangement and constructional detail of infill walls have significant effects on the seismic performance of RC frames. During 2008 Wenchuan Earthquake, a lot of masonry infilled RC frame structures suffered serious damages due to detrimental effects brought about by infill walls rigidly connected to the main structure. In the updated Chinese seismic design code, the flexible connection between infill walls and RC frames is recommended in order to reduce the unfavorable interaction between them. In this study, seven full-scale, single-bay and single-storey RC frame specimens, five with masonry infill wall and flexible connection, one with masonry infill wall and rigid connection, and one without infill wall, were tested under low-cycle reversed loads. For the specimens with flexible connection, the variable parameters are the type and amount of constructional column, the amount of tie steel bar, and the amount of vertical slit set in the infill wall. Based on the test results, the damage behavior, lateral strength, displacement ductility ratio, stiffness degradation, and energy dissipation of the specimen are compared. The influence of constructional details of infill walls on the seismic behavior of RC frames is analyzed. It is found that with the addition of masonry infill wall rigidly connected to the frame, the lateral strength, the stiffness and the energy-dissipation capacity of the bare RC frame increase significantly while the displacement ductility ratio decreases significantly. Compared with the infill wall with rigid connection, the strength, the stiffness and the energy-dissipation capacity contributed by the infill wall with flexible connection drop significantly, but the displacement ductility ratio of the frame rises up. (C) 2015 Elsevier Ltd. All rights reserved.
引用
收藏
页码:70 / 84
页数:15
相关论文
共 50 条
  • [41] Full-scale tests on steel frames under cyclic loading
    Ivanyi, M.
    Ivanyi, P.
    Ivanyi, M. M.
    5TH INTERNATIONAL WORKSHOP ON MULTI-RATE PROCESSES AND HYSTERESIS (MURPHYS 2010), 2010, 268
  • [42] Influence of masonry strength and rectangular spiral shear reinforcement on infilled RC frames under cyclic loading
    Kakaletsis, D. J.
    Computational Methods and Experimental Measurements XIII, 2007, 46 : 643 - 653
  • [43] Performance evaluation of masonry-infilled RC frames under cyclic loading based on damage mechanics
    Perera, R
    ENGINEERING STRUCTURES, 2005, 27 (08) : 1278 - 1288
  • [44] Experimental study on seismic performance of full-scale RC frame infilled with autoclaved aerated concrete blocks
    Li, Jianhui
    Xue, Yantao
    Xiao, Congzhen
    Chang, Zhaozhong
    Li, Ying
    Tumu Gongcheng Xuebao/China Civil Engineering Journal, 2015, 48 (08): : 12 - 18
  • [45] Experimental and Numerical Modelling of Shear Behaviour of Full-scale RC Slabs Under Concentrated Loads
    Nana, W. S. A.
    Bui, T. T.
    Limam, A.
    Abouri, S.
    STRUCTURES, 2017, 10 : 96 - 116
  • [46] Parametric analyses and feasibility study of moment-resisting timber frames under service load
    Vilguts, Aivars
    Stamatopoulos, Haris
    Malo, Kjell Arne
    ENGINEERING STRUCTURES, 2021, 228
  • [47] Experimental and Numerical Investigation of the Seismic Performance of RC Moment-Resisting Frames with Additive Materials Having Porosity in Connections
    Bakhshipour, M.
    Esfandiari, J.
    Roudsari, M. T.
    IRANIAN JOURNAL OF SCIENCE AND TECHNOLOGY-TRANSACTIONS OF CIVIL ENGINEERING, 2023, 48 (4) : 2323 - 2340
  • [48] Finite element analysis of RC moment-resisting frames to assess effective slab width; a parametric study
    Khalili, Ali
    Nateghi-Alahi, Fariborz
    STRUCTURES, 2023, 57
  • [49] Experimental and numerical investigation on cyclic behavior of masonry infilled RC frames retrofitted with partially bonded CFRP strips
    Sakr, Mohammed A.
    El-Khoriby, Saher R.
    Seleemah, Aymen A.
    Aboelnour, Mustafa M.
    Osama, Bothaina
    STRUCTURES, 2021, 33 : 2238 - 2252
  • [50] Experimental study of the effect of interfacial gaps on the in-plane behaviour of masonry infilled RC frames
    Nasiri, Ehsan
    Liu, Yi
    BRICK AND BLOCK MASONRY: TRENDS, INNOVATIONS AND CHALLENGES, 2016, : 1301 - 1307