Full-scale experimental study on masonry infilled RC moment-resisting frames under cyclic loads

被引:65
|
作者
Jiang, Huanjun
Liu, Xiaojuan [1 ]
Mao, Junjie
机构
[1] Tongji Univ, State Key Lab Disaster Reduct Civil Engn, Shanghai 200092, Peoples R China
基金
中国国家自然科学基金;
关键词
Infill wall; Reinforced concrete moment-resisting frame; Connection detail; Cyclic loading test; Seismic performance; REINFORCED-CONCRETE FRAMES; BUILDINGS; BEHAVIOR; PANELS; TESTS;
D O I
10.1016/j.engstruct.2015.02.008
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The reinforced concrete (RC) moment-resisting frames with masonry infill walls are widely used in buildings. It has been well recognized that the arrangement and constructional detail of infill walls have significant effects on the seismic performance of RC frames. During 2008 Wenchuan Earthquake, a lot of masonry infilled RC frame structures suffered serious damages due to detrimental effects brought about by infill walls rigidly connected to the main structure. In the updated Chinese seismic design code, the flexible connection between infill walls and RC frames is recommended in order to reduce the unfavorable interaction between them. In this study, seven full-scale, single-bay and single-storey RC frame specimens, five with masonry infill wall and flexible connection, one with masonry infill wall and rigid connection, and one without infill wall, were tested under low-cycle reversed loads. For the specimens with flexible connection, the variable parameters are the type and amount of constructional column, the amount of tie steel bar, and the amount of vertical slit set in the infill wall. Based on the test results, the damage behavior, lateral strength, displacement ductility ratio, stiffness degradation, and energy dissipation of the specimen are compared. The influence of constructional details of infill walls on the seismic behavior of RC frames is analyzed. It is found that with the addition of masonry infill wall rigidly connected to the frame, the lateral strength, the stiffness and the energy-dissipation capacity of the bare RC frame increase significantly while the displacement ductility ratio decreases significantly. Compared with the infill wall with rigid connection, the strength, the stiffness and the energy-dissipation capacity contributed by the infill wall with flexible connection drop significantly, but the displacement ductility ratio of the frame rises up. (C) 2015 Elsevier Ltd. All rights reserved.
引用
收藏
页码:70 / 84
页数:15
相关论文
共 50 条
  • [31] Experimental study on seismic behavior of RC frames with slab and infilled masonry walls
    College of Civil Engineering, Huaqiao University, Quanzhou 362021, China
    Jianzhu Jiegou Xuebao, 2009, SUPPL. 2 (127-132):
  • [32] Influence of connection and constructional details on masonry-infilled RC frames under cyclic loading
    Peng, Quanmin
    Zhou, Xiaojie
    Yang, Chenghao
    SOIL DYNAMICS AND EARTHQUAKE ENGINEERING, 2018, 108 : 96 - 110
  • [33] Experimental Study on Robustness of Three-Dimensional Steel Moment-Resisting Frames
    Li, Honghao
    STRUCTURES CONFERENCE 2018: BLAST, IMPACT LOADING, AND RESPONSE; AND RESEARCH AND EDUCATION, 2018, : 263 - 272
  • [34] Experimental and numerical study of a proposed moment-resisting connection for precast concrete frames
    Fathi, M.
    Parvizi, M.
    Karimi, T.
    Afreidoun, M. H.
    SCIENTIA IRANICA, 2018, 25 (04) : 1977 - 1986
  • [35] Performance evaluation of seismic resisting and retrofitting measures for full-scale brick masonry buildings under earthquake loads
    Central Building Research Institute, Roorkee 247 667, India
    J Struct Eng, 2007, 1 (56-62):
  • [36] Improved beam-to-column joints for moment-resisting frames - An experimental study
    Sotirov, P
    Rangelov, N
    Ganchev, O
    Georgiev, T
    Petkov, ZB
    Milev, J
    STABILITY AND DUCTILITY OF STEEL STRUCTURES, 1999, : 241 - 248
  • [37] Seismic Response Comparison of Full-Scale Moment-Resisting Timber Frame and Joint Test Result
    Namba, Tokikatsu
    Nakagawa, Takafumi
    Isoda, Hiroshi
    Kado, Yuji
    Odani, Ryuki
    Takino, Atsuo
    JOURNAL OF STRUCTURAL ENGINEERING, 2023, 149 (07)
  • [38] Full-scale test of a steel moment-resisting frame with composite floor under a penultimate edge column removal scenario
    Wang, Junjie
    Wang, Wei
    Bao, Yihai
    Lehman, Dawn
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2019, 162
  • [39] An experimental study on strengthening of masonry infilled RC frames using diagonal CFRP strips
    Altin, Sinan
    Anil, Oezguer
    Kara, M. Emin
    Kaya, Mustafa
    COMPOSITES PART B-ENGINEERING, 2008, 39 (04) : 680 - 693
  • [40] Steel-FRP Reinforced Concrete Moment-Resisting Frames under Lateral Loads: Numerical Investigation
    Fahmy, Mohamed F. M.
    Ibrahim, Haitham A.
    JOURNAL OF COMPOSITES FOR CONSTRUCTION, 2020, 24 (06)