Influence of sodium hypochlorite and EDTA on the microtensile bond strength of a self-etching adhesive system

被引:28
|
作者
Cechin, Doglas [1 ]
Farina, Ana Paula [2 ]
Galafassi, Daniel [3 ]
Baroni Barbizam, Joao Vicente [4 ]
Milori Corona, Silmara Aparecida [5 ]
Carlini-Junior, Bruno [4 ]
机构
[1] Univ Estadual Campinas, Endodont Div, Dept Restorat Dent, Piracicaba Dent Sch, Piracicaba, SP, Brazil
[2] Univ Estadual Campinas, Prosthodont Div, Dept Restorat Dent, Piracicaba Dent Sch, Piracicaba, SP, Brazil
[3] Univ Sao Paulo, Dept Restorat Dent, Ribeirao Preto Dent Sch, BR-14049 Ribeirao Preto, SP, Brazil
[4] Univ Passo Fundo, Dept Restorat Dent, Sch Dent, Passo Fundo, RS, Brazil
[5] Univ Sao Paulo, Dept Restorat Dent, Sch Dent, BR-14049 Ribeirao Preto, SP, Brazil
关键词
Dentin-bonding agents; EDTA; Sodium hypochlorite; SMEAR LAYER REMOVAL; ENDODONTIC IRRIGANTS; SURFACE-AREA; NAOCL; IRRIGATION; RESISTANCE; FRACTURE; AGENTS; TIME;
D O I
10.1590/S1678-77572010000400011
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Chemical substances used during biomechanical preparation of root canals can alter the composition of dentin surface and affect the interaction with restorative materials. Objective: The purpose of this study was to evaluate the microtensile bond strength (mu TBS) of a self-etching adhesive system to dentin irrigated with sodium hypochlorite (NaOCl) and ethylenediaminetetraacetic acid (EDTA). Material and Methods: Thirty human third molars were sectioned 3 mm below the occlusal surface, polished with 600- to 1200-grit silicon carbide papers, and randomly divided into 3 groups: G1 (control): no irrigating solution; G2: 1% NaOCl; and G3: 1% NaOCl followed by the application of 17% EDTA. The specimens received the self-etching adhesive system (XENO III - Dentsply), restored with microhybrid composite resin (Z250 - 3M ESPE), sectioned and trimmed to create 4 hourglass-shaped slabs of each tooth. The slabs were tested in microtensile strength in a universal testing machine (Emic DL 2000) at a crosshead speed of 0.5 mm/min until fracture. The results were analyzed statistically by ANOVA and Newman-Keuls test. Results: Mean mu TBS values and standard deviations in MPa were: G1 = 11.89 +/- 4.22; G2 = 19.41 +/- 5.32; G3 = 11.34 +/- 4.73. 1% NaOCl increased the adhesive resistance significantly (p<0.001/F = 22.5763). The application of 1% NaOCl/ 17% EDTA resulted in statistically similar mu TBS to the control group. Conclusions: None of the irrigants affected negatively the mu TBS of XENO III to dentin. The use of 1% NaOCl alone resulted in higher bond strength than the other treatments. The combination of 1% NaOCl and 17% EDTA produced similar bond strength to that of untreated dentin.
引用
收藏
页码:385 / 389
页数:5
相关论文
共 50 条
  • [21] Reinforcement of bond strength of self-etching orthodontic adhesive
    Horiuchi, Shinya
    Kuroda, Shingo
    Hiasa, Masahiro
    Suge, Toshiyuki
    Saku, Seitaro
    Hamada, Kenichi
    Matsuo, Takashi
    Asaoka, Kenzo
    Tanaka, Eiji
    ANGLE ORTHODONTIST, 2012, 82 (01) : 30 - 35
  • [23] Microtensile bond strength of composite resin and glass ionomer cement with total-etching or self-etching universal adhesive
    Munari, Lais S.
    Antunes, Alberto N. G.
    Monteiro, Debora D. H.
    Moreira, Allyson N.
    Alvim, Hugo H.
    Magalhaes, Claudia S.
    INTERNATIONAL JOURNAL OF ADHESION AND ADHESIVES, 2018, 82 : 36 - 40
  • [24] Microtensile bond strengths to enamel of self-etching and one bottle adhesive systems
    Pilecki, P
    Stone, DG
    Sherriff, M
    Watson, TF
    JOURNAL OF ORAL REHABILITATION, 2005, 32 (07): : 531 - 540
  • [25] Influence of Blood Contamination on Bond Strength of a Self-etching Adhesive to Dental Tissues
    Tachibana, Arlene
    Castanho, Gisela Muassab
    Vieira, Samuel Nilo
    Matos, Adriana Bona
    JOURNAL OF ADHESIVE DENTISTRY, 2011, 13 (04): : 349 - 358
  • [26] Influence of thermal and mechanical load cycling on microtensile bond strengths of total and self-etching adhesive systems
    Mitsui, FHO
    Peris, AR
    Cavaleanti, AN
    Marchi, GM
    Pimenta, LAF
    OPERATIVE DENTISTRY, 2006, 31 (02) : 240 - 247
  • [27] Microtensile bond strength test of self-etching primer and acid etching adhesive systems using different c-factors.
    Soares, FZM
    Mallmann, A
    Muench, A
    Cardoso, PEC
    JOURNAL OF DENTAL RESEARCH, 2003, 82 : 161 - 161
  • [28] The effect of self-etching adhesive system associated with different energy densities of Nd:YAG laser on microtensile bond strength to dentin
    Barcellos D.C.
    Holleben P.
    Fonseca B.M.
    Sabino B.C.
    Gonçalves S.E.P.
    Lasers in Dental Science, 2018, 2 (3) : 157 - 162
  • [29] Bond strength of a self-etching adhesive system to caries-affected dentin
    Yazici, AR
    Akca, T
    Özgünaltay, G
    Dayangaç, B
    OPERATIVE DENTISTRY, 2004, 29 (02) : 176 - 181
  • [30] Microtensile dentin bond strength of self-etching and single-bottle adhesive systems in different cavity configurations
    Mallmann, A
    Soares, FZM
    Placido, E
    Ferrari, M
    Cardoso, PEC
    JOURNAL OF ADHESIVE DENTISTRY, 2003, 5 (02): : 121 - 127