Accuracy of ultrasonic detection of renal scarring in different centres using DMSA as the gold standardle

被引:30
|
作者
Sinha, Manish D.
Gibson, Paul
Kane, Tom
Lewis, Malcolm A.
机构
[1] Guys & St Thomas NHS Fdn Trust, Dept Paediat Nephrol, Eveline Childrens Hosp, London SE1 7EH, England
[2] Royal Lancaster Infirmary, Dept Paediat, Lancaster, England
[3] Blackpool Victoria Hosp, Dept Radiol, Blackpool, England
[4] Cent Manchester & Royal Manchester Childrens Hosp, NHS Trust, Dept Paediat Nephrol, Manchester M27 4HA, Lancs, England
关键词
children; dimercaptosuccinic acid scan; investigation; ultrasound scan; urinary tract infection;
D O I
10.1093/ndt/gfm155
中图分类号
R3 [基础医学]; R4 [临床医学];
学科分类号
1001 ; 1002 ; 100602 ;
摘要
Background. There is an ongoing debate over the radiological investigations of children with urinary tract infections (UTIs) with some authorities suggesting that ultrasound scan (USS) alone is an accurate tool to diagnose renal parenchymal scarring post-pyelonephritis. All studies on this subject have been performed at paediatric teaching centres whereas most children with UTIs are managed by General Paediatricians in District General Hospitals (DGHs) in the United Kingdom. We wished to identify whether results of scans in DGHs differed from those in teaching centres. Methods. We looked at all children with a clinical history of UTIs having a DMSA and USS over a one year period in two DGHs and one teaching centre. A total of 476 children's results were reviewed, 297 from the DGHs and 179 from the teaching centre. Results. The cohort had a total of 949 renal units. There were 79 scarred renal units (kidneys) on DMSA (8%) in 72 patients (15%). Just 18 renal units were detected as being scarred on USS (22.8%). Nine of 32 scarred renal units in the teaching centre were detected compared with nine of 47 in the DGHs (P = 0.40). Thirty-nine (49%) of the scarred renal units were in patients > 5-years old. Of these 12 (30.7%) were detected on USS, nine of 17 within the teaching centre compared with just three of 22 at the DGHs (P = 0.01). Conclusion. Overall only a small percentage of scars are detected on USS. In the over 5-year old group, where USS alone might be preferred, DGHs were significantly worse at detecting scarred kidneys. We conclude that if the detection of renal scars is a prime reason for imaging in children with UTIs, ultrasonography alone is inappropriate at any age and DMSA ought to be the primary investigation.
引用
收藏
页码:2213 / 2216
页数:4
相关论文
共 50 条
  • [31] Sensitive and simultaneous detection of different disease markers using multiplexed gold nanorods
    Key Laboratory of Theoretical Chemistry and Molecular Simulation of Ministry of Education, School of Chemistry and Chemical Engineering, Hunan University of Science and Technology, Xiangtan, China
    不详
    不详
    Anal. Chim. Acta, (108-114):
  • [32] Detection of gold nanoparticles with different sizes using absorption and fluorescence based method
    Zuber, Agnieszka
    Purdey, Malcolm
    Schartner, Erik
    Forbes, Caroline
    van der Hoek, Benjamin
    Giles, David
    Abell, Andrew
    Monro, Tanya
    Ebendorff-Heidepriem, Heike
    SENSORS AND ACTUATORS B-CHEMICAL, 2016, 227 : 117 - 127
  • [33] Diagnostic accuracy of different display types in detection of recurrent caries under restorations by using CBCT
    Baltacioglu, Ismail H.
    Eren, Hakan
    Yavuz, Yasemin
    Kamburoglu, Kivanc
    DENTOMAXILLOFACIAL RADIOLOGY, 2016, 45 (06)
  • [34] Improving the accuracy of NIR detection of moldy core in apples using different diameter correction methods
    Li, Hanlin
    Zan, Jiajun
    Zhang, Linxin
    Hou, Binyan
    Sun, Tong
    Hu, Dong
    POSTHARVEST BIOLOGY AND TECHNOLOGY, 2025, 219
  • [35] Diagnostic Accuracy of CBCT for the Detection of Accessory Mental Foramina Using Different Devices and Imaging Modalities
    Hui, Liuling
    Hung, Kuofeng
    Singh, Pradeep
    Montalvao, Carls
    Yeung, Andy Wai Kan
    Matinlinna, Jukka P.
    Bornstein, Michael M.
    INTERNATIONAL JOURNAL OF PERIODONTICS & RESTORATIVE DENTISTRY, 2023, 43 (03) : 311 - +
  • [36] Label-free colorimetric detection of tetracycline using gold nanoparticles with different surface charge
    Yang, Kai
    Zhu, Ruiqi
    Li, Zhongping
    Shuang, Shaomin
    Zhai, Yan
    Dong, Chuan
    TALANTA, 2024, 266
  • [37] A high accuracy ultrasonic distance measurement system using binary frequency shift-keyed signal and phase detection
    Huang, SS
    Huang, CF
    Huang, KN
    Young, MS
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2002, 73 (10): : 3671 - 3677
  • [38] High-accuracy detection and location of gas leaks based on adaptive weighted data fusion using an ultrasonic transducer array
    Tang, Nian
    Wang, Tao
    Zhang, Manjun
    Li, Li
    Sun, Dongwei
    Li, Xiaodian
    Lan, Jianglong
    Ji, Jiawen
    Yang, Ming
    INSIGHT, 2024, 66 (12) : 729 - 736
  • [39] Comparison of detection accuracy of perfusion defects in SPECT for different reconstruction strategies using polar-map quantitation
    Pretorius, PH
    Gifford, HC
    Narayanan, MV
    Dahlberg, ST
    King, MA
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2003, 50 (05) : 1569 - 1574
  • [40] Improved DNA sequencing accuracy and detection of heterozygous alleles using manganese citrate and different fluorescent dye terminators
    Korch, C
    Drabkin, H
    GENOME RESEARCH, 1999, 9 (06) : 588 - 595